Please read and understand all instructions before installing, operating, or performing maintenance on this pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage. Retain this manual for future reference.

  • Elektros sauga: Ensure power supply is disconnected before any installation or maintenance. All electrical wiring must be performed by a qualified electrician and comply with local codes and regulations.
  • Slėgio sauga: This pump operates under pressure. Ensure all connections are secure and leak-free before operation.
  • Temperatūros sauga: The pump handles fluids up to +130°C (266°F) and short-term up to +140°C (284°F). Exercise caution to avoid burns from hot surfaces or fluids.
  • Montavimas: This pump is designed for hydronic circulating applications. Do not use for purposes other than its intended use.

2. Produktas baigtasview

The Wilo Top S 2 x 40 is a wet rotor hydronics circulating pump designed for residential and light commercial applications. It features a robust construction from stainless steel, polypropylene, and metal-impregnated carbon, ensuring durability and efficient performance. This model includes a two-speed motor for manual capacity adjustment.

Wilo Top S 2 x 40 Circulating Pump

1 paveikslas: Wilo Top S 2 x 40 Wet Rotor Hydronics Circulating Pump. This image displays the main unit of the circulating pump, highlighting its compact design and connection points.

Pagrindinės funkcijos:

  • Wet rotor, seal-less design for quiet and maintenance-free operation.
  • Two pre-selectable speed stages for manual capacity adjustment.
  • Constructed from stainless steel, polypropylene, and metal-impregnated carbon for durability.
  • Cataphoretic coated pump housing for enhanced corrosion resistance.
  • Permitted temperature range: -20°C to +130°C (short-term to +140°C).
  • Pump communication based on simple plug technology for reliable retrofitting.

3. Diegimas ir sąranka

Proper installation is crucial for the safe and efficient operation of your Wilo circulating pump. It is highly recommended that installation be performed by a qualified professional.

3.1 Patikrinimai prieš montavimą:

  • Patikrinkite, ar siurblio tūristage (115-Volt) matches your electrical supply.
  • Ensure the installation location is suitable, providing adequate space for maintenance and ventilation.
  • Confirm that the system piping is clean and free of debris.

3.2 Mechaninis montavimas:

  • The pump requires 4 Bolt 2-Inch HV flanges (not included) for connection to the piping system. Ensure these flanges are correctly sized and installed.
  • Install the pump in a horizontal position with the motor shaft horizontal to prevent air pockets and ensure proper lubrication.
  • Use appropriate gaskets and tighten flange bolts evenly to prevent leaks.
  • Support the pump and piping adequately to prevent strain on the connections.

3.3 Elektros jungtis:

  • All electrical work must comply with national and local electrical codes.
  • Prijunkite siurblį prie specialios, tinkamai apsaugotos elektros grandinės.
  • Užtikrinkite tinkamą siurblio įžeminimą.
  • Refer to the wiring diagram provided with the pump for specific connection details.

4. Naudojimo instrukcijos

Once installed and electrically connected, the Wilo Top S 2 x 40 pump is ready for operation.

4.1 Pradinis paleidimas:

  • Before starting, ensure the system is filled with fluid and properly vented to remove any air.
  • Open all necessary valves in the system.
  • Apply power to the pump. The pump should start circulating fluid.
  • Patikrinkite, ar nėra neįprastų garsų ar vibracijos.

4.2 Greičio reguliavimas:

The Wilo Top S 2 x 40 features two pre-selectable speed stages. These can be adjusted manually to optimize flow rate and energy consumption for your specific hydronic system requirements. Consult your system design for the appropriate speed setting.

4.3 Įprastas veikimas:

The pump is designed for continuous operation within its specified temperature range of -20°C to +130°C. Monitor the system for consistent performance and absence of leaks.

5. Priežiūra

The Wilo Top S 2 x 40 wet rotor design is largely maintenance-free. However, periodic checks are recommended to ensure optimal performance and longevity.

5.1 Reguliarūs patikrinimai:

  • Vizuali apžiūra: Periodically inspect the pump for any signs of leaks, corrosion, or damage to the housing or electrical connections.
  • Triukšmas ir vibracija: Listen for any unusual noises or excessive vibrations, which could indicate a problem.
  • Sistemos slėgis: Ensure the system pressure remains within the recommended operating range.

5.2 Valymas:

Siurblio išorę laikykite švarią, be dulkių ir šiukšlių, kad būtų užtikrintas tinkamas šilumos išsklaidymas.

5.3 Pasiruošimas žiemai:

If the pump is installed in an unheated area subject to freezing temperatures, ensure the system is properly drained or protected with antifreeze to prevent damage.

6. Problemų sprendimas

This section provides solutions to common issues you might encounter with your Wilo circulating pump. For complex problems, contact a qualified technician.

ProblemaGalima priežastisSprendimas
Siurblys neįsijungiaNėra maitinimo
Variklis sulaikytas
Neteisingi laidai
Patikrinkite grandinės pertraukiklį / saugiklį
Susisiekite su techninės priežiūros specialistu
Verify wiring with diagram
Mažas srauto greitisOras sistemoje
Partially closed valves
Clogged impeller/piping
Neteisingas greičio nustatymas
Ventiliacijos sistema
Open all valves
Inspect and clean system
Adjust speed setting
Per didelis triukšmas/vibracijaOras sistemoje
Laisvas tvirtinimas
Svetimkūnis siurblyje
Vent system thoroughly
Priveržkite tvirtinimo varžtus
Susisiekite su techninės priežiūros specialistu
Nuotėkis jungtyseLoose flange bolts
Pažeista tarpinė
Tighten bolts evenly
Pakeiskite tarpiklį

7. Specifikacijos

Detailed technical specifications for the Wilo Top S 2 x 40 Circulating Pump, Model 2067579.

AtributasVertė
Modelio numeris2067579
GamintojasWilo
Prekės svoris45.8 svaro
Pakuotės matmenys18.9 x 16 x 13 colio
MedžiagaPolipropilenas, nerūdijantis plienas
Maitinimo šaltinisAC/DC
ttage115 voltų
Prekės pakuotės kiekis1
Permitted Temperature Range-20°C to +130°C (short-term to +140°C)
Shutoff Head40 pėdų
Flange RequirementUses 4 Bolt 2-Inch HV flanges (not included)

8. Garantija ir palaikymas

8.1 Informacija apie garantiją:

Wilo Commercial Building Services products, including this circulating pump, come with a 2 metų ribota garantija nuo įsigijimo datos. Ši garantija taikoma medžiagų ir gamybos defektams, atsiradusiems įprasto naudojimo ir priežiūros sąlygomis. Išsaugokite pirkimo įrodymą, jei galėtumėte pateikti pretenzijas dėl garantijos.

8.2 Klientų aptarnavimas:

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Wilo customer service. Have your pump model number (2067579) and date of purchase ready when contacting support.

You can find contact information for Wilo customer service on their official websvetainėje arba per savo vietinį platintoją.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.