Intermatic UWZ48E-240U

Intermatic UWZ48E-240U Hour Meter Instruction Manual

Model: UWZ48E-240U

1. Įvadas

This manual provides detailed instructions for the installation, operation, and maintenance of the Intermatic UWZ48E-240U Hour Meter. This device is designed to accurately record operating hours for various electrical equipment. Please read this manual thoroughly before installation and operation to ensure proper function and safety.

2. Saugos informacija

ĮSPĖJIMAS: Risk of electric shock. Installation and servicing should be performed by qualified personnel only. Disconnect power at the circuit breaker or fuse box before installing or servicing the unit.

  • Visada laikykitės vietinių elektros kodeksų ir taisyklių.
  • Ensure the power supply matches the meter's voltage rating (240V AC, 60Hz).
  • Nenaudokite matuoklio, jei jis atrodo pažeistas.
  • Saugokite vaikus nuo elektros instaliacijos.

3. Produktas baigtasview

The Intermatic UWZ48E-240U is a flush-mount hour meter designed for precise time tracking. It features a clear display for accumulated hours and offers both quick connect and screw terminals for versatile wiring options.

Intermatic UWZ48E-240U Hour Meter with dimensions

1 paveikslas: Priekyje view of the Intermatic UWZ48E-240U Hour Meter. The image shows the meter's face with the Intermatic logo, a six-digit hour display, and electrical ratings (UWZ 48-L, 110-127V~ 60Hz). Please note that while the image displays 110-127V, the product model UWZ48E-240U is rated for 240V AC, 60Hz as per specifications. Dimensions of 1.79 inches by 1.79 inches are indicated on the sides.

3.1 Pagrindinės funkcijos:

  • Flush mount design with retaining bracket.
  • Combo quick connect and screw terminals.
  • 240V AC, 60Hz operation.
  • Patvari plastikinė konstrukcija.
  • Compact dimensions: 1.79"W x 1.79"H.

4. Montavimas

4.1 Montavimas

  1. Įsitikinkite, kad maitinimas atjungtas nuo šaltinio.
  2. Create a panel cutout of 1.79" x 1.79" (45.5 x 45.5 mm). The panel thickness can be up to 0.35" (9 mm).
  3. Insert the hour meter into the cutout from the front of the panel.
  4. Secure the unit in position using the provided plastic slip-on retaining bracket from the rear of the panel.
  5. Neprivaloma: For 72 mm square or round openings, an optional 72 mm bezel can be used (not included).

4.2 Laidai

The UWZ48E-240U features combo quick connect and screw terminals. Connect the meter in parallel with the load or circuit you wish to monitor. Ensure correct voltage (240V AC, 60Hz) is supplied to the meter terminals.

  • Greitas prisijungimas: Use appropriate spade connectors for a secure connection.
  • Sraigtiniai gnybtai: Strip wire insulation to the recommended length, insert into the terminal, and tighten the screw firmly.

After wiring, ensure all connections are secure and insulated before restoring power.

5. Operacija

The Intermatic UWZ48E-240U Hour Meter operates automatically when power is supplied to its terminals. The mechanical display will increment, showing the total accumulated operating hours. The meter does not have a reset function, providing a continuous record of equipment usage.

  • The display shows hours in a six-digit format, typically with the last digit representing tenths of an hour.
  • No user interaction is required for operation once installed and powered.

6. Priežiūra

The UWZ48E-240U Hour Meter is designed for maintenance-free operation. However, periodic inspection is recommended to ensure optimal performance.

  • Valymas: If necessary, gently wipe the display window with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Patikra: Periodically check wiring connections for tightness and ensure the meter is securely mounted.
  • Aplinkos sąlygos: Ensure the operating environment remains within the specified temperature range (up to 160°F / 71°C).

7. Problemų sprendimas

ProblemaGalima priežastisSprendimas
Meter display is blank or not incrementing.No power to the meter, incorrect wiring, or meter malfunction.
  • Verify power supply to the circuit.
  • Patikrinkite visų laidų jungtis, ar jos tinkamai sujungtos, ar jos tinkamai priveržtos ir poliškos.
  • Įsitikinkite, kad ttage matches the meter's rating (240V AC).
  • If power and wiring are correct, the meter may require replacement.
Netikslūs valandų rodmenys.Intermittent power supply or meter malfunction.
  • Ensure a stable power supply to the monitored equipment.
  • If issues persist, the meter may require replacement.

8. Specifikacijos

ModelisUWZ48E-240U
Prekės ženklasIntermatic
ttage240 voltų
Dažnis60 Hz
Dabartinis reitingas1 Amps
Jungties tipasSpade, Screw Terminals
Montavimo tipasFlush Mount (Wall Mount)
MedžiagaPlastikiniai
SpalvaBaltas
Gaminio matmenys (P x A)1.79 colių x 1.79 colio (45.5 x 45.5 mm)
Skydelio išpjova1.79 colių x 1.79 colio (45.5 x 45.5 mm)
Max Panel Thickness0.35 colio (9 mm)
Viršutinės temperatūros įvertinimas160 laipsniai pagal Farenheitą (71 laipsnių Celsijaus)
SertifikataiCSA
Prekės svoris0.2 svaro

9. Garantija ir palaikymas

Dėl garantijos informacijos ir techninės pagalbos kreipkitės į oficialią „Intermatic“ svetainę. websvetainėje arba susisiekite su jų klientų aptarnavimo skyriumi. Išsaugokite pirkimo kvitą kaip pirkimo įrodymą.

Galite aplankyti „Intermatic“ parduotuvė „Amazon“ platformoje Norėdami gauti daugiau informacijos apie produktą.