Red Lion RJC-100

„Red Lion RJC-100“ 1 AG konvertuojamo reaktyvinio siurblio naudotojo vadovas

Model: RJC-100 | Brand: Red Lion

1. Įvadas

The Red Lion RJC-100 1 HP convertible jet pump is designed for supplying fresh water to cottages, cabins, and small homes from wells up to 90 feet deep. This versatile pump can be configured for both shallow well applications (down to 25 feet) with the injector installed directly on the pump, or deep well applications (25 to 90 feet) with the injector installed in the well. Optimal performance in deep well applications requires using the injector specifically designed for this pump.

Pagrindinės funkcijos:

  • Taikymas: Ideal for shallow wells (less than 25 ft.) and deep wells (25 to 90 ft) with a deep well injector.
  • Konstrukcija: Features a rugged cast iron casing, glass-filled thermoplastic impeller and diffuser, and a thermally protected motor for durability.
  • Variklis: Dvigubas ttage (115/230 V) motor with copper windings for high efficiency and dependable life. Operates at 16.4 Amps at 115 Volts and 8.2 Amps esant 230 voltų.
  • ttage Nustatymas: Factory pre-set to 230 Volts, easily switchable to 115 Volts. Voltage must match the incoming power source.
  • Siurblio specifikacijos: Delivers 20 GPM at 5-ft. lift (30 PSI), with 1-1/4 inch FNPT intake and 1-inch discharge. Includes a 30/50 pressure switch and injector kit.

2. Saugos informacija

WARNING: Risk of severe injury or death by electrical shock, or damage to system.

  • Always disconnect the electrical power before touching the pump or performing any maintenance.
  • A Ground Fault Circuit Interrupter (GFCI) is required for electrical connections.
  • Jei maitinimo laidas pažeistas, jį gali pakeisti tik kvalifikuotas personalas.
  • Failure to comply with national and local electrical and plumbing codes and with recommendations, warnings, and instructions contained in this manual may result in electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
  • Šią įrangą turi montuoti ir aptarnauti techniškai kvalifikuotas personalas, susipažinęs su tinkamu tinkamų įrankių, įrangos ir procedūrų parinkimu ir naudojimu.

3. Produktas baigtasview

The Red Lion RJC-100 jet pump is engineered for reliable water supply. Below are visual representations and descriptions of the pump and its key components.

Red Lion RJC-100 1 HP Convertible Jet Pump with included injector kit components.

Figure 1: Red Lion RJC-100 1 HP Convertible Jet Pump with included injector kit components.

Komponentai:

Išpjova view of the Red Lion RJC-100 jet pump highlighting internal components like the dual voltage motor, cast iron housing, and thermoplastic impeller.

2 pav. Iškirpta view of the Red Lion RJC-100 jet pump highlighting internal components like the dual voltage motor, rugged cast iron housing, and glass-filled thermoplastic impeller and diffuser.

Components of the injector kit for the Red Lion RJC-100 jet pump, including injector assembly, venturis, nozzles, hardware, and gasket.

Figure 3: Included Injector Kit components for the Red Lion RJC-100, featuring the injector assembly, various venturis (purple for depths >45', brown for depths <45'), nozzles (white for depths >45', green for depths <45'), hardware, and a rubber gasket.

Product Visual Tour:

1 vaizdo įrašas: rotacija view of the Red Lion RJC-PREM series jet pump, showcasing its exterior design and compact form factor.

4. Sąranka ir diegimas

4.1 Patikrinimai prieš montavimą:

Before installing the pump, ensure the pressure tank is correctly pre-charged. If replacing an old galvanized tank, remove any existing air volume controls, bleeder valves, or snifter valves. Select an installation location where potential water leaks will not cause property damage and adequate drainage is available. Level the tank as necessary if the flooring is uneven.

Video 2: This video provides a step-by-step guide on how to install or adjust a pressure tank with a jet pump system, including checking pre-charge pressure and making pipe connections.

4.2 Well Type Configuration:

The RJC-100 is convertible for both shallow and deep well applications. Ensure the correct injector setup is used for your well depth.

Diagram showing the Red Lion RJC-100 jet pump with the injector attached directly to the pump for shallow well applications (up to 25 feet).

Figure 4: For shallow wells (down to 25 feet), attach the injector directly to the pump.

Diagram showing the Red Lion RJC-100 jet pump with the injector installed in the well for deep well applications (26 to 90 feet).

Figure 5: For deep wells (26 to 90 feet), install the injector in the well.

4.3 Elektros jungtis:

The pump is dual voltage (115/230 Volt) and factory set to 230 Volts. If wiring to a 115 Volt power source, the voltage switch must be changed to 115 Volts. Failure to do so will prevent the pump from performing as expected. Refer to the owner's manual for detailed instructions on changing the voltage nustatymas.

5. Operacija

Before starting the pump for the first time or after any maintenance that drains the system, it must be properly primed by filling it with water. Ensure all connections are secure and airtight to prevent air leaks that could affect performance.

6. Priežiūra

Regular maintenance ensures the longevity and efficient operation of your Red Lion RJC-100 jet pump. The well tank and the entire system must be checked annually by a qualified professional to ensure proper function and identify any potential issues before they escalate.

7. Problemų sprendimas

If your jet pump frequently starts and stops (rapid cycling), it indicates a potential issue within the system that can shorten the pump's lifespan. The following video and points outline common causes and actions to address rapid cycling.

Video 3: This video explains common causes of rapid cycling in a jet pump system, such as pipe leaks, air leaks in the tank, incorrect motor voltage settings, and pressure switch failure, along with troubleshooting steps.

Dažnos problemos ir sprendimai:

  • Pipe Size and Leaks: Ensure existing intake and discharge pipes are not smaller than the pump's ports. Check for leaks in the intake pipe; loose connections or cracked pipes can cause rapid cycling.
  • Air Leaks in Tank: In systems with pressure tanks, incorrect air pressure or air leaks in the tank above the water level can cause rapid cycling. Check system fittings for airtightness. If unresolved air leaks are present, replace the tank.
  • Incorrect Motor Voltage Switch Setting: Patikrinkite variklio garsumątage indikatorius atitinka ttage of your power source (115V or 230V). Adjust if necessary by disconnecting power, removing the terminal cover, and shifting the terminal block to the correct voltage location. Do not move the white lead wires on L1 and L2.
  • Pressure Switch Failure: If all other probable causes have been reviewed and the pump continues to rapid cycle, the pressure switch may need adjustment or replacement. Contact a licensed plumber for assistance.

8. Specifikacijos

Detailed specifications for the Red Lion RJC-100 1 HP Convertible Jet Pump:

AtributasVertė
Prekės ženklasRed Lion
Modelio numeris602038
Arklio jėgos1 AG
ttage115/230 Volt (Dual Voltage)
Maksimalus srautas20 galono per minutę (GPM)
Maksimalus kėlimo aukštis90 pėdų
MedžiagaKetaus
Gaminio matmenys20.58 colio ilgio x 9 colių pločio x 10 colio aukščio
Prekės svoris44 svaro
Įtraukti komponentai30/50 Pressure Switch, Injector Kit, Pump

Dimensions and Performance:

Technical drawing showing dimensions of the Red Lion RJC-100 jet pump.

Figure 6: Technical drawing illustrating the dimensions of the Red Lion RJC-100 jet pump.

Performance table for the Red Lion RJC-100 jet pump, detailing GPM at various suction lifts and discharge pressures.

Figure 7: Performance table for the Red Lion RJC-100 jet pump, detailing Gallons Per Minute (GPM) at various suction lifts and discharge pressures (PSI).

9. Garantija ir palaikymas

Informacija apie garantiją:

The Red Lion RJC-100 jet pump comes with a 2-year warranty. Please refer to your purchase documentation for specific terms and conditions.

Klientų aptarnavimas:

For items purchased within 30 days, please refer to Amazon's 30-day return policy. For issues after 30 days, if Amazon.com is the seller, your product is covered by the terms outlined in your owner's manual. Our staff can also assist with troubleshooting or installation assistance. Contact information for support is typically found in the included installation manual or on the Red Lion websvetainę.

Susiję dokumentai - RJC-100

Preview „Red Lion“ siurblio trikčių šalinimo vadovas
Išsamus „Red Lion“ siurblių trikčių šalinimo vadovas, apimantis dažniausiai pasitaikančias negilių gręžinių purkštuvinių siurblių, transformuojamų purkštuvinių siurblių, panardinamųjų siurblių, komunalinių siurblių ir varikliu varomų perpumpavimo siurblių problemas. Apima sprendimus, kai variklis neužsiveda, siurblys netiekia vandens, trūksta užpildymo skysčio, sumažėja našumas ir dažnai cikliškai įsijungia.
Preview „Red Lion RJC-50-PREM/RJC-75-PREM“ konvertuojamo reaktyvinio siurblio naudotojo vadovas
Discover the Red Lion RJC-50-PREM/RJC-75-PREM Convertible Jet Pump, designed for efficient operation in shallow wells up to 25 feet and deep wells up to 90 feet. This manual provides essential information on installation, operation, and maintenance for optimal performance. Covered by a 3-year limited warranty.
Preview Red Lion Pump & Tank Selection Guide: 1-2-3 Easy Steps
A comprehensive 1-2-3 guide from Red Lion University on selecting the appropriate pump and tank for water systems. Covers depth to water level, required water flow (gpm), minimum well diameter, and details typical installation configurations for shallow well jet pumps, convertible jet pumps, and deep well submersible pumps.
Preview „Red Lion“ siurblių trikčių šalinimo vadovas: sprendimai, skirti reaktyviniams, panardinamiesiems ir perpumpavimo siurbliams
Comprehensive troubleshooting guide for Red Lion water pumps, including Shallow Well Jet Pumps (e.g., RJS-50-PREM), Convertible Jet Pumps (e.g., RJC-50), 4" Submersible Well Pumps (e.g., RL12G10-3W2V), Submersible Utility & Sump Pumps, RL-S Cast Iron Surface Effluent Pumps, RL-50 Transfer Pumps, and RLSP/RLHE Sprinkler Pumps. Find solutions for common issues like motor failure, priming problems, low pressure, and more.
Preview RJS-75SS/RL15HS Jet Pump/Tank System Owner's Manual
Comprehensive owner's manual for the Red Lion RJS-75SS/RL15HS jet pump and tank system, covering installation, safety, operation, maintenance, and troubleshooting.
Preview Red Lion PWJET50 Shallow Well Jet Pump Owner's Manual and Installation Guide
This document provides comprehensive owner's manual and installation guidance for the Red Lion PWJET50 Shallow Well Jet Pump. It details safety instructions, installation procedures, operation, maintenance, and troubleshooting for efficient water supply in rural applications.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.