This manual provides essential information for the safe and effective installation, operation, and maintenance of the Eaton FAZ-C10/3-NA Miniature Circuit Breaker. Please read this manual thoroughly before attempting any installation or operation. Retain this manual for future reference.
2. Saugos informacija
WARNING: Risk of electric shock and fire hazard. Installation and servicing must be performed by qualified personnel only.
- Always disconnect power at the main service panel before working on or near the circuit breaker.
- Naudokite tinkamą blokavimą/tagout procedures to prevent accidental re-energization.
- Įsitikinkite, kad visa instaliacija atitinka nacionalinius ir vietinius elektros kodeksus.
- Nenaudokite automatinio jungiklio, jei jis atrodo pažeistas.
- Niekada neaplenkite ir tampsu grandinės pertraukiklio apsaugos mechanizmais.
- Dėvėkite tinkamas asmenines apsaugos priemones (AAP), įskaitant izoliuotas pirštines ir akių apsaugą.
3. Produkto aprašymas
The Eaton FAZ-C10/3-NA is a high-performance miniature circuit breaker designed for reliable overcurrent protection in various electrical applications. It features a 3-pole configuration, rated for 10 Amperes, and is suitable for both AC (277/480V) and DC (48V) systems. With a 10 kAIC (kiloampere interrupting capacity) rating and a C-Curve tripping characteristic, it provides protection against short circuits and overloads in circuits with moderate inrush currents. This device is UL 489 listed, ensuring compliance with safety standards.

This image shows the Eaton FAZ-C10/3-NA miniature circuit breaker, highlighting its compact design and terminal connections for DIN rail mounting. The front panel displays the brand, model, and electrical ratings.
4. Sąranka ir diegimas
Installation of the Eaton FAZ-C10/3-NA circuit breaker must be performed by a qualified electrician in accordance with all applicable electrical codes and standards.
4.1 Montavimas
- The FAZ-C10/3-NA is designed for DIN rail mounting.
- Ensure the DIN rail is securely fastened within an appropriate enclosure.
- Snap the circuit breaker onto the DIN rail by hooking the top edge onto the rail and pressing down until it clicks into place.
4.2 Laidai
- Before wiring, ensure all power to the circuit is OFF and verified with a voltage testeris.
- Connect the incoming power conductors to the top terminals of the circuit breaker.
- Connect the load conductors to the bottom terminals of the circuit breaker.
- Ensure all terminal screws are tightened to the manufacturer's specified torque settings to prevent loose connections and potential overheating.
- Verify correct polarity for DC applications.
5. Operacija
The Eaton FAZ-C10/3-NA circuit breaker provides automatic protection against overcurrents. Its operation is straightforward:
5.1 Įjungimas / išjungimas
- To turn the circuit ON, push the toggle handle to the 'ON' (upward) position.
- To turn the circuit OFF, push the toggle handle to the 'OFF' (downward) position.
5.2 Išjungimas ir atstatymas
- In the event of an overload or short circuit, the circuit breaker will automatically 'trip' to the center position, interrupting the circuit to prevent damage.
- Before resetting a tripped breaker, identify and correct the cause of the overload or short circuit.
- To reset, first push the handle fully to the 'OFF' position, then push it to the 'ON' position.
- If the breaker immediately trips again, do not force it. Consult a qualified electrician.
6. Priežiūra
The Eaton FAZ-C10/3-NA miniature circuit breaker is designed for maintenance-free operation under normal conditions. However, periodic inspection is recommended.
- Vizuali apžiūra: Periodiškai tikrinkite grandinės pertraukiklį, ar nėra kokių nors fizinių pažeidimų, spalvos pakitimų ar atsilaisvinusių jungčių.
- Valymas: If necessary, gently clean the exterior of the circuit breaker with a dry, lint-free cloth. Do not use solvents or abrasive cleaners.
- Nėra vartotojo aptarnaujamų dalių: The circuit breaker contains no user-serviceable parts. Do not attempt to open or repair the unit.
7. Problemų sprendimas
If you encounter issues with your Eaton FAZ-C10/3-NA circuit breaker, consider the following common scenarios:
7.1 Dažnas automatinio jungiklio išsijungimas
- Perkrova: The circuit may be drawing more current than the breaker's 10A rating. Reduce the load on the circuit.
- Trumpas sujungimas: A direct connection between live and neutral/ground wires. This requires immediate investigation by a qualified electrician.
- Sugedęs prietaisas: Disconnect appliances one by one to identify a faulty device.
7.2 Breaker Does Not Reset
- Ensure the handle is pushed fully to the 'OFF' position before attempting to reset to 'ON'.
- If it still does not reset, there might be a persistent fault or internal damage. Do not force the handle. Contact a qualified electrician.
7.3 No Power to Circuit
- Check if the circuit breaker is in the 'ON' position.
- Verify that the main power supply to the panel is active.
- If other breakers in the panel are working, the issue might be isolated to this circuit or the breaker itself.
For persistent or complex issues, always consult a qualified electrician.
8. Specifikacijos
| Funkcija | Specifikacija |
|---|---|
| Prekės ženklas | Eaton |
| Modelis | FAZ-C10/3-NA |
| Dabartinis reitingas | 10 Amps |
| Lenkų skaičius | 3 |
| ttage AC | 277/480 voltai |
| ttage DC | 48 voltų |
| Pertraukiamoji galia (AIC) | 10 kA |
| Tripping Curve | C-Curve (5-10X In) |
| Montavimo tipas | DIN bėgio kalnas |
| Standartai | UL 489 |
| Prekės svoris | 0.36 kilogramo |
9. Garantija ir palaikymas
For specific warranty information, please refer to the documentation provided at the time of purchase or contact Eaton directly. Eaton stands behind the quality of its products.