The Orbit 56854 Hose End Water Flow Meter is designed to accurately measure water consumption from your outdoor hose faucet. This device helps in monitoring water usage for various tasks such as watering plants, filling pools, or other outdoor activities, promoting water conservation. It provides readings in both single-use and total accumulated water volume, displayed in either gallons or liters. This meter is intended for outdoor use with cold water only.

Saugos informacija

  • This device is for outdoor use with cold water only. Do not use with hot water or indoors.
  • Do not expose the meter to freezing temperatures. Disconnect and store indoors during winter months to prevent damage.
  • Įsitikinkite, kad visos jungtys yra tvirtos, kad išvengtumėte nuotėkio.
  • Laikykite baterijas vaikams nepasiekiamoje vietoje. Tinkamai išmeskite panaudotas baterijas.

Sąranka

1. Akumuliatoriaus įdėjimas

  1. Suraskite baterijų skyriaus dangtelį matuoklio gale.
  2. Atsargiai nuimkite dangtelį.
  3. Insert one CR2032 battery, ensuring the positive (+) side faces up.
  4. Saugiai uždėkite akumuliatoriaus skyriaus dangtelį.
Atgal view of the Orbit 56854 water flow meter, showing the battery compartment.

Paveikslėlis: Nugara view of the Orbit 56854 water flow meter, showing the battery compartment for CR2032 battery installation.

2. Connecting the Meter

  1. Thread the female end of the flow meter onto your standard 3/4-inch outdoor faucet or hose. Hand-tighten until secure.
  2. Attach your garden hose to the male end of the flow meter. Hand-tighten until secure.
  3. Ensure the flow direction arrow on the meter points in the direction of water flow (away from the faucet).
Orbit 56854 water flow meter connected to an outdoor faucet and garden hose.

Image: The Orbit 56854 water flow meter connected between an outdoor faucet and a green garden hose, ready for use.

3. Unit Selection (Gallons or Liters)

After battery installation, the meter will display the default unit. To switch between gallons (GAL) and liters (L), press and hold the RESET button for approximately 3 seconds until the unit changes on the LCD screen.

Naudojimo instrukcijos

The Orbit 56854 meter features two measurement modes: SRAUTAS (single-use) and IŠ VISO (accumulated). Use the EKRANAS button to switch between these modes and the RESET button to clear readings.

Šoninė view of the Orbit 56854 water flow meter showing the digital display and control buttons.

Vaizdas: Šoninė view of the Orbit 56854 water flow meter, highlighting the digital display and the two control buttons (DISPLAY and RESET).

1. Measuring Single-Use Flow (FLOW Mode)

  1. Paspauskite EKRANAS button until the screen shows 'FLOW' or a similar indicator for single-use measurement.
  2. Turn on the water. The meter will begin displaying the current volume of water flowing through it.
  3. When you turn off the water, the final volume for that single use will remain on the display for a short period before automatically resetting for the next use.
  4. To manually reset the FLOW reading at any time, press the RESET mygtuką vieną kartą.

2. Measuring Total Accumulated Flow (TOTAL Mode)

  1. Paspauskite EKRANAS button until the screen shows 'TOTAL' or a similar indicator for accumulated measurement.
  2. This mode continuously tracks the total volume of water that has passed through the meter since the last manual reset.
  3. The TOTAL reading will not automatically reset after each use.
  4. To reset the TOTAL accumulated reading, press and hold the RESET button for approximately 3 seconds until the display clears.
Close-up of the Orbit 56854 water flow meter's digital display showing a water volume reading.

Vaizdas: Stambus planas view of the Orbit 56854 water flow meter's digital LCD screen, displaying a measured water volume.

Priežiūra

Valymas

Nuvalykite skaitiklį reklamaamp cloth as needed. Do not use abrasive cleaners or solvents, as these may damage the display or casing.

Baterijos keitimas

When the display becomes dim or unresponsive, it is time to replace the CR2032 battery. Follow the battery installation steps outlined in the Setup section.

Sandėliavimas

Disconnect the water flow meter from the hose and faucet before the first frost or during periods of non-use in cold weather. Store the meter indoors in a dry, temperature-controlled environment to prevent damage from freezing water.

Trikčių šalinimas

  • Nėra ekrano / pritemdytas ekranas: Check the CR2032 battery. Ensure it is inserted correctly with the positive (+) side up. Replace the battery if necessary.
  • Netikslūs rodmenys: Ensure the meter is installed correctly with the flow arrow pointing in the direction of water flow. Verify there are no significant leaks at the connections.
  • Nuotėkiai jungtyse: Ensure the rubber washers are properly seated in both ends of the meter. Hand-tighten connections firmly. Do not overtighten.
  • Meter Not Resetting: For single-use (FLOW) mode, it should reset automatically or with a single press of the RESET button. For total (TOTAL) mode, hold the RESET button for 3 seconds. If issues persist, try replacing the battery.

Specifikacijos

FunkcijaSpecifikacija
Prekės ženklasOrbita
Modelio numeris56854N
MedžiagaPlastikiniai
SpalvaJuoda
Gaminio matmenys3.8D x 8.3W x 4.5H centimetrai
Prekės svoris0.15 svaro
Ryšio dydis3/4-inch standard hose/faucet
Baterijos tipas1 x CR2032 (įtraukta)
Ekrano vienetaiGallons (GAL) or Liters (L)

Informacija apie garantiją

This Orbit product is covered by a manufacturer's warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Orbit websvetainėje. Išsaugokite pirkimo įrodymą garantiniams reikalavimams.

Pagalba klientams

If you have any questions, require technical assistance, or need to report an issue with your Orbit 56854 Hose End Water Flow Meter, please contact Orbit customer support. Contact information can typically be found on the Orbit websvetainėje arba ant produkto pakuotės.

© 2026 Orbit. Visos teisės saugomos.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.