Pedrollo PLURIJET M4/80-N

Pedrollo PLURIJET M4/80-N Self-Priming Multi-Stage Water Pump Instruction Manual

Model: PLURIJET M4/80-N | Brand: Pedrollo

1. Įvadas

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Pedrollo PLURIJET M4/80-N self-priming multi-stage water pump. Please read these instructions carefully before use and retain them for future reference.

The PLURIJET series offers a new, more compact, and robust design. It is recommended for applications requiring a quiet and high-performance self-priming pump.

Pedrollo PLURIJET M4/80-N Self-Priming Multi-Stage Water Pump

Figure 1: Pedrollo PLURIJET M4/80-N Self-Priming Multi-Stage Water Pump. This image shows the overall design of the pump, highlighting its compact and robust construction.

2. Techninės charakteristikos

  • Completely renewed range with a new design.
  • Improved hydraulic performance for higher efficiency.
  • Reduced energy consumption.
  • One of the quietest models in the centrifugal pump series.
  • Enhanced priming capabilities.

3. Įdiegimas ir naudojimas

The PLURIJET pumps are suitable for use with clean water, even when air is present, and with liquids that are not chemically aggressive towards the materials from which the pump is made. Due to their quietness, reliability, and low energy consumption, they are recommended for domestic and civil applications such as water supply systems, pressure boosting, and irrigation.

3.1. Application Limits

  • Liquid temperature: from -10 °C to +40 °C
  • Ambient temperature: up to +40 °C
  • Manometric suction lift: up to 9 m (HS)
  • Maksimalus darbinis slėgis: 6 barai
  • Nuolatinis aptarnavimas: S1

4. Sąranka

Proper setup is crucial for optimal performance and longevity of the pump. Ensure the pump is installed in a dry, well-ventilated area, protected from direct sunlight and frost.

4.1. Elektrinis sujungimas

Connect the pump to a single-phase 230 V, 50 Hz power supply. Ensure the electrical installation complies with local regulations and safety standards. The power cable is not included and must be appropriately sized for the pump's power requirements (0.55 kW / 0.75 HP).

4.2. Hydraulic Connection

Connect the suction and delivery pipes to the pump's threaded ports. Ensure all connections are watertight to prevent air ingress, which can affect priming and pump performance. Use appropriate sealants and fittings.

4.3. Siurblio užpildymas

Before first use, or after any period of disuse, the pump must be primed. Fill the pump body completely with clean water through the dedicated filling port until water overflows. Close the filling port securely before starting the pump.

5. Naudojimo instrukcijos

Once installed and primed, the pump is ready for operation. Ensure the suction line is submerged in water and free from obstructions.

5.1. Siurblio paleidimas

Switch on the power supply to the pump. The pump will begin to draw water. Monitor the pressure gauge (if installed) to ensure proper operation. The pump is designed for continuous service (S1).

5.2. Siurblio sustabdymas

To stop the pump, switch off the power supply. For prolonged periods of disuse, especially in freezing conditions, drain the pump completely to prevent damage.

6. Priežiūra

Regular maintenance ensures the longevity and efficient operation of your Pedrollo pump.

6.1. Įprastiniai patikrinimai

  • Periodiškai tikrinkite, ar aplink jungtis nėra nuotėkių.
  • Ensure the pump is free from excessive vibration or unusual noises.
  • Verify that the ventilation openings on the motor are clear.

6.2. Pasiruošimas žiemai

In areas subject to freezing temperatures, drain the pump and associated piping completely to prevent damage from ice expansion. Store the pump in a dry, frost-free location if possible.

7. Problemų sprendimas

Šiame skyriuje pateikiami dažniausiai pasitaikančių problemų, su kuriomis galite susidurti naudodami savo siurblį, sprendimai.

ProblemaGalima priežastisSprendimas
Siurblys neįsijungiaNo power supply, motor overload, seized impellerCheck power connection and circuit breaker. Allow motor to cool. Inspect impeller for obstructions.
Siurblys veikia, bet vandens neduodaPump not primed, air leak in suction line, suction lift too high, clogged suction filterRe-prime the pump. Check all suction connections for leaks. Verify suction lift is within limits. Clean suction filter.
Sumažėjęs srautas arba slėgisPartial blockage, worn impeller, air in systemCheck for blockages in pipes. Inspect impeller for wear. Bleed air from the system.
Per didelis triukšmas ar vibracijaCavitation, foreign object in pump, worn bearingsEnsure adequate water supply to prevent cavitation. Inspect pump for foreign objects. Contact service for bearing replacement.

8. Specifikacijos

Detailed technical specifications for the Pedrollo PLURIJET M4/80-N pump.

BūdingasVertė
ModelisPLURIJET M4/80-N
Maitinimo šaltinisSingle-phase 230 V, 50 Hz
Galia (kW)0.55 kW
Galia (AG)0.75 AG
Srauto greitis (Q)5 ÷ 80 L/min (up to 4.8 m³/h)
Galva (H)50 ÷ 10 m (max 50m)
Siurbimas1"
Siurblio korpuso medžiagaAISI 304 nerūdijantis plienas
Sparnuotės medžiagaNoryl
Skysčio temperatūros diapazonas-10 °C iki +40 °C
Aplinkos temperatūraIki +40 °C
Maks. Darbinis slėgis6 barų
Izoliacijos klasėF
ApsaugaIP X4
Gamintojo nuoroda43PJA5084A1

8.1. Characteristic Curves and Performance Data

Refer to the following graph for detailed performance characteristics (Head vs. Flow Rate) at 50 Hz, n=2900 1/min, HS=0m.

Pedrollo PLURIJET M4/80-N Performance Curves

Figure 2: Characteristic Curves and Performance Data. This graph illustrates the relationship between head (H in meters) and flow rate (Q in L/min or m³/h) for various PLURIJET models, including the M4/80-N.

8.2. Construction Characteristics

Key components and their materials:

  • Siurblio korpusas: Stainless steel AISI 304, with threaded ports in compliance with ISO 228/1.
  • Motor Backplate: Stainless steel AISI 304.
  • Darbaračiai: Noryl FE1520PW.
  • Difuzoriai: Noryl FE1520PW with anti-wear ring.
  • Variklio velenas: Stainless steel EN 10088-3 - 1.4104.
  • Mechaninis sandariklis:
    • Seal Model: AR-13
    • Shaft Diameter: Ø 13 mm
    • Stationary Ring Material: Ceramic
    • Rotational Ring Material: Graphite
    • Elastomer: NBR
  • Guoliai:
    • PLURIJETm 3/60, 3/80, 3/100, 4/80-N: 6202 ZZ - C3 (6201 ZZ)
    • PLURIJETm 4/100-N: 6203 ZZ (6203 ZZ)
  • Capacitor (Single-phase 230V or 240V):
    • PLURIJETm 3/60-N: 10 µF 450 VL (25 µF 250 V)
    • PLURIJETm 3/80-N: 12.5 µF 450 VL (25 µF 250 V)
    • PLURIJETm 4/80, 3/100-N: 14 µF 450 VL (25 µF 250 V)
    • PLURIJETm 4/100-N: 20 µF 450 VL (60 µF 300 V)
  • Elektros variklis:
    • PLURIJETm: Single-phase 230 V - 50 Hz with thermal overload protector built into the winding.
    • PLURIJET: Three-phase 230/400 V - 50 Hz.
    • Pumps fitted with the three-phase motor option offer IE2 (IEC 60034-30) class high performance.
    • Stator and rotor are made out of magnetic sheet with low iron loss.
    • Insulation: F class.
    • Protection: IP X4.

8.3. Matmenys

Refer to the diagram and table below for the physical dimensions of the pump.

Pedrollo PLURIJET M4/80-N Dimensional Drawing

Figure 3: Dimensional Drawing. This diagram provides a detailed view of the pump's dimensions (in mm), including various measurements labeled 'a', 'b', 'h1', 'h2', 'h3', 'n', 'n1', 'w', 'z', 's'.

ModelisUostaiMatmenys (mm)
VienfazėTrijų faziųDN1DN2abh1h2h3nn1wz
PLURIJETm 3/60-NPLURIJET 3/60-N1"1"11335718210251183126879
PLURIJETm 3/80-NPLURIJET 3/80-N1"1"11335718210251183126879
PLURIJETm 4/80-NPLURIJET 4/80-N1"1"11335718210251183126879
PLURIJETm 3/100-NPLURIJET 3/100-N1"1"11335718210251183126879
PLURIJETm 4/100-NPLURIJET 4/100-N1"1"13841120210251183126879

Note: The table above includes dimensions for various PLURIJET models. The PLURIJET M4/80-N shares dimensions with other models as indicated.

9. Garantija ir palaikymas

For warranty information, please refer to the documentation provided with your purchase or contact your authorized Pedrollo dealer. Keep your proof of purchase for warranty claims.

For technical support, spare parts, or service, please contact your local Pedrollo service center or the retailer from whom you purchased the pump. Provide the model number (PLURIJET M4/80-N) and serial number (if applicable) when seeking assistance.

© 2023 Pedrollo. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.