Leviton GFSW1-W

Leviton GFSW1-W Smartlockpro GFCI Receptacle & Switch Instruction Manual

Model: GFSW1-W

1. Įvadas

This manual provides essential information for the safe installation, operation, and maintenance of your Leviton GFSW1-W Smartlockpro Tamper-Resistant Combo GFCI Receptacle & Switch. This device combines a ground fault circuit interrupter (GFCI) receptacle with a standard switch, offering enhanced electrical safety and convenience in a single unit. Please read these instructions thoroughly before beginning installation or use.

2. Saugos informacija

WARNING: RISK OF ELECTRIC SHOCK OR FIRE. IMPROPER INSTALLATION OR USE MAY RESULT IN SERIOUS INJURY OR DEATH.

  • Prieš montuodami arba atlikdami šio įrenginio techninę priežiūrą, visada išjunkite maitinimą grandinės pertraukikliu arba saugiklių dėžute.
  • Montavimą turi atlikti kvalifikuotas elektrikas, laikydamasis visų nacionalinių ir vietinių elektros kodeksų.
  • Nenaudokite šio prietaiso su aliuminio laidais. Naudokite tik su variniais arba variu padengtais laidais.
  • Įsitikinkite, kad visos laidų jungtys yra tvirtos ir tinkamai izoliuotos.
  • This device is designed for indoor use in dry locations unless otherwise specified.

3. Produkto ypatybės

  • Savitikros funkcija: Provides continuous ground fault protection by automatically testing the GFCI. It detects and trips on actual ground faults even during self-testing.
  • Initial Power-Up Test: Tests the GFCI within 3 seconds of initial power-up.
  • Auto-Monitoring: Exceeds UL requirements by adapting and shifting to more frequent testing if a potential problem is detected.
  • Protection Status Indicator: An LED light provides simple, intuitive feedback on power and protection status, including indication of line/load reversal.
  • Patented Bridge Contact: Ensures no power is delivered to the receptacle face if improperly wired (line-load reversed).
  • Enhanced Immunity: Improved immunity to high-frequency noise reduces nuisance tripping.
  • Surge Resistance: Advanced electronics provide superior resistance to electrical surges and over-voltages.
  • Lockout Action: Patented lockout action prevents reset if the GFCI is damaged and cannot respond to a ground fault.
  • TampEr-Resistant talpykla: Designed to prevent insertion of foreign objects into the receptacle openings.
  • Patvari konstrukcija: Features an impact-resistant thermoplastic cover and polycarbonate body.

4. Specifikacijos

AtributasVertė
ModelisGFSW1-W
ttage125 voltų
Amperage (Receptacle)15 Amps
Jungiklio įvertinimas15 Amp - 120 VAC
NEMA konfigūracija5-15R
SpalvaBaltas
MedžiagaThermoplastic face, Polycarbonate body
Gaminio matmenys (ilgis x plotis)1.7 colio ilgio x 1.13 colio pločio
Darbinė temperatūra-35°C iki 66°C
Agency StandardsUL Standard 943 Class A (GFCI), UL 498 (Receptacles), CSA Certified, NOM Certified

5. Įdiegimas (sąranka)

SVARBU: Turn OFF power at the circuit breaker or fuse box before wiring. Failure to do so may result in serious injury or death.

  1. Paruoškite laidus: Carefully remove the existing device from the wall box. Identify the LINE (incoming power) and LOAD (downstream protection) wires. If you are unsure, consult a qualified electrician.
  2. Prijunkite laidus:
    • Connect the LINE hot wire to the brass LINE terminal.
    • Connect the LINE neutral wire to the silver LINE terminal.
    • If protecting downstream receptacles, connect the LOAD hot wire to the brass LOAD terminal.
    • If protecting downstream receptacles, connect the LOAD neutral wire to the silver LOAD terminal.
    • Connect the ground wire to the green ground screw.
    • Įsitikinkite, kad visos jungtys yra sandarios ir saugios.
  3. Sumontuokite įrenginį: Carefully fold the wires into the wall box. Mount the GFCI receptacle and switch into the wall box using the provided screws.
  4. Sieninės plokštės montavimas: Attach the wallplate (not included) over the device.
  5. Atkurti maitinimą: Turn ON power at the circuit breaker or fuse box.
  6. Išbandykite GFCI: Perform the initial test as described in the "Operation" section to ensure proper functioning.
Leviton GFSW1-W Smartlockpro GFCI Receptacle and Switch installed in a white tiled wall.

Image: The Leviton GFSW1-W Smartlockpro GFCI Receptacle and Switch, white in color, shown installed on a white tiled wall. It features a rocker switch at the top, and below it, a GFCI receptacle with "RESET" and "TEST" buttons, and a small LED indicator light.

6. Operacija

The Leviton GFSW1-W combines a standard light switch with a GFCI-protected receptacle.

  • Jungiklio funkcija: The top rocker switch operates connected lighting or other loads. Press the top to turn ON, press the bottom to turn OFF.
  • GFCI Receptacle: The lower portion provides a 15 Amp, 125 Volt tamper-resistant outlet with ground fault protection.
  • GFCI testavimas:
    1. Kištukas alamp or other device into the GFCI receptacle and turn it ON.
    2. Paspauskite mygtuką „TEST“ (bandymas). GFCI turėtų suveikti ir lamp/device should turn OFF. The LED indicator may change color or turn off.
    3. Paspauskite mygtuką „RESET“ (atstatyti). GFCI turėtų būti atstatytas, oamp/device should turn ON. The LED indicator should return to its normal operating state (e.g., green).
    4. If the GFCI does not trip or reset as described, it may be improperly wired or defective. Do not use and consult a qualified electrician.
  • GFCI nustatymas iš naujo: If the GFCI trips (power is interrupted), press the "RESET" button firmly. If it does not reset, check for a ground fault or consult the troubleshooting section.

7. Priežiūra

Regular testing of your GFCI device is crucial to ensure continued protection against ground faults. Leviton recommends testing your GFCI monthly.

  • Follow the "Testing the GFCI" procedure outlined in the Operation section at least once a month.
  • If the GFCI fails to trip or reset during testing, it must be replaced immediately.
  • Keep the device and wallplate clean. Use a soft, damp valymui skirtą šluostę; venkite abrazyvinių valiklių ar tirpiklių.

8. Problemų sprendimas

ProblemaGalima priežastisSprendimas
GFCI nebus atstatytas.
  • GFCI nėra maitinimo.
  • GFCI is improperly wired (LINE/LOAD reversed).
  • A ground fault exists in the circuit or connected appliance.
  • GFCI is defective.
  • Patikrinkite grandinės pertraukiklį.
  • Patikrinkite laidų jungtis.
  • Unplug all appliances and try to reset. If it resets, plug in appliances one by one to identify the faulty one.
  • Pakeiskite GFCI.
GFCI dažnai keliauja.
  • A persistent ground fault.
  • Perkrova grandinėje.
  • Moisture or damage to connected appliances/cords.
  • Inspect wiring and appliances for faults.
  • Reduce the number of devices on the circuit.
  • Inspect and replace damaged items.
Jungiklis neveikia.
  • Įrenginyje nėra maitinimo.
  • Incorrect wiring of the switch.
  • Sugedęs jungiklis.
  • Patikrinkite grandinės pertraukiklį.
  • Verify switch wiring.
  • Pakeiskite įrenginį.

9. Garantija ir palaikymas

Limited Two-Year Product Warranty: Leviton warrants this product to be free from defects in material and workmanship under normal use and service for a period of two years from the date of original purchase. For complete warranty details, please refer to the documentation included with your product or visit the official Leviton websvetainę.

Klientų aptarnavimas: If you require assistance with installation, troubleshooting, or have questions about your Leviton GFSW1-W device, please contact Leviton Customer Service. Contact information can typically be found on the product packaging or the official Leviton websvetainė (www.leviton.com).