VTSYIQI ETCR007

VTSYIQI ETCR007 AC/DC Clamp Leakage Current Sensor User Manual

Model: ETCR007 | Brand: VTSYIQI

1. Įvadas

The VTSYIQI ETCR007 AC/DC Clamp Leakage Current Sensor is designed for precise measurement of AC/DC current and leakage current. It operates under line voltages up to 600V. This device utilizes advanced CT technology and digital integration for accurate, non-contact current measurement. It is suitable for various applications including power analysis, electrical testing, industrial maintenance, and scientific research.

This manual provides essential information for the safe and effective use of your ETCR007 sensor. Please read it thoroughly before operation.

2. Produkto ypatybės

  • Funkcija: Measures AC/DC current and leakage current.
  • Matavimo metodas: Clip-on CT, non-contact measurement.
  • Clamp Dydis: φ7 mm.
  • Įvesties diapazonas: 0mA to 60.0A AC/DC.
  • Išėjimas ttage: Selectable 10mV/A or 100mV/A.
  • Rezoliucija: 1mA AC/DC.
  • Tikslumas: ±3%FS (at 23°C ±5°C, below 5%RH).
  • Fazės klaida: ≤3° (AC 50Hz/60Hz; 23°C ±2°C).
  • Dažnių diapazonas: AC: 45Hz-400Hz; DC: DC-100kHz.
  • Išvesties sąsaja: BNC plug.
  • Maitinimas: 9V battery (6LR61/6F22) or external power supply.
  • Saugos standartai: Complies with IEC1010-1, IEC1010-2-032, Pollution level 2, CAT ΙΙΙ (600V).

3. Saugos informacija

To ensure safe operation and prevent electric shock or damage to the device, please observe the following safety precautions:

  • Always disconnect the line being tested before opening the clamp sensor housing.
  • Do not use the sensor on circuits exceeding AC600V line voltage.
  • Įsitikinkite, kad akumuliatoriaus skyrius veikimo metu yra sandariai uždarytas.
  • Do not operate the device in wet environments or if it appears damaged.
  • Refer to the applicable safety rules: IEC1010-1, IEC1010-2-032, Pollution level 2, CAT ΙΙΙ (600V).
  • Keep the device away from strong electromagnetic fields to avoid measurement interference.

4. Pakuotės turinys

Išpakuodami patikrinkite, ar visos prekės yra ir nepažeistos:

  • AC/DC Clamp Leakage Current Sensor (1 piece)
  • 9V Battery (6F22, 1 piece)
  • User Manual / Warranty Card / Certification (1 copy)
VTSYIQI ETCR007 AC/DC Clamp Leakage Current Sensor and accessories in box

Image 1: The VTSYIQI ETCR007 clamp sensor, output cable, and user manual, shown partially in its packaging box.

VTSYIQI ETCR007 AC/DC Clamp Leakage Current Sensor, cable, and manual removed from box

Image 2: The VTSYIQI ETCR007 clamp sensor, its attached cable, and the user manual, displayed outside of the product box.

Video 1: An unboxing video demonstrating the contents of the VTSYIQI ETCR007 package, including the clamp sensor and accessories.

5. Sąranka

5.1 Akumuliatoriaus įdėjimas

  1. Raskite baterijų skyriaus dangtelį jutiklio gale.
  2. Open the cover and insert the provided 9V (6F22) battery, ensuring correct polarity.
  3. Saugiai uždarykite akumuliatoriaus skyriaus dangtelį.

5.2 Connecting the Output Wire

The sensor comes with an integrated output cable. The core wire provides the signal positive output, and the shielding wire serves as the signal ground. Connect the BNC plug of this cable to a compatible measuring instrument (e.g., digital multimeter, oscilloscope, power quality analyzer).

Close-up of the BNC connector on the VTSYIQI ETCR007 sensor's output cable

3 paveikslėlis: Išsamus view of the BNC connector at the end of the sensor's output cable, ready for connection to a measuring device.

6. Operacija

6.1 Powering On and Range Selection

  1. Locate the POWER switch on the sensor.
  2. Slide the switch to select the desired output range: 10mV / A or 100mV / A. The "OFF" position powers down the device.
  3. The selected range determines the output voltage per ampere of measured current. For example, 100mV/A means 100mV output for every 1A of current.
Close-up of the power switch and output range selector on the VTSYIQI ETCR007 sensor

4 pav.: Stambus planas view of the sensor's control panel, showing the power switch with 10mV/A, 100mV/A, and OFF positions.

6.2 Nulinis kalibravimas

Before taking measurements, especially for DC current or leakage current, it is crucial to perform a zero calibration to eliminate external electric field interference and ensure accuracy.

  1. Ensure no current is flowing through the clamp žandikaulis.
  2. Locate the ZERO adjustment knob (often a rotary knob) on the sensor.
  3. Rotate the knob until the connected measuring instrument displays zero current.
Kl stambus planasamp jaw and zero adjustment area on the VTSYIQI ETCR007 sensor

5 paveikslėlis: Išsamus view klamp jaw and the area where the zero adjustment knob is typically located, indicated by a yellow arrow symbol.

6.3 Matavimai

  1. Atidarykite klamp žandikaulį paspausdami gaiduką.
  2. Place the wire carrying the current to be measured inside the center of the clamp jaw. Ensure only one conductor is within the jaw for accurate measurement.
  3. Atleiskite gaiduką, kad uždarytumėteamp žandikaulis tvirtai apvyniokite laidininką.
  4. Read the current value from your connected measuring instrument, applying the selected output ratio (e.g., if 100mV/A is selected and the instrument reads 500mV, the current is 5A).
  5. For optimal accuracy, ensure the tested wire is positioned in the jaw's center.
Šoninė view of the VTSYIQI ETCR007 AC/DC Clamp Leakage Current Sensor

6 paveikslėlis: Šoninis profilisfile of the VTSYIQI ETCR007 clamp sensor, showing the ergonomic design for gripping and clamping around a conductor.

7. Specifikacijos

ParametrasVertė
FunkcijaMeasurement of AC/DC current, leakage current
Maitinimo šaltinis9V Battery (6LR61/6F22), or external power supply
Baterijos veikimo laikasMaždaug 100 valandos nepertraukiamo naudojimo
Bandymo režimasClip-on CT, non-contact measurement
Clamp Dydisφ7 mm
Įvesties diapazonas0mA - 60.0A AC/DC
Išėjimas ttage10mV/A; 100mV/A (corresponding)
Išvesties diapazonas1V peak max
Rezoliucija1mA AC/DC
Tikslumas±3%FS (23°C ±5°C, below 5%RH)
Fazės klaida≤3° (AC 50Hz/60Hz; 23°C ±2°C)
KalibravimasAdjust ZERO to calibrate
Išvesties laido ilgis2m
Matmenys (LWH)168 mm × 65 mm × 34 mm
Dažnis (AC)45Hz - 400Hz
Frequency (DC)DC - 100kHz
Bandomoji padėtisTested wire in the jaw center
Linija VoltageAC600V
Svoris170 g (su akumuliatoriumi)
Darbo srovė5 mA
Darbinė temperatūra-10°C iki 50°C
Darbinė drėgmėŽemiau 80 % RH
Laikymo temperatūra-10°C iki 60°C
Sandėliavimas DrėgmėŽemiau 70 % RH
Izoliacinis stiprumasAC3700V/rms (between alloy of clamp and housing)
Applicable Safety RulesIEC1010-1, IEC1010-2-032, Pollution level 2, CAT ΙΙΙ (600V)
Galinis view of the VTSYIQI ETCR007 sensor showing product label with barcode 00770112 and specifications

Image 7: The back of the sensor, displaying a product label with model information, specifications, and a barcode (00770112).

8. Priežiūra

  • Valymas: Use a soft, dry cloth to clean the sensor. Do not use abrasive cleaners or solvents.
  • Saugykla: When not in use for extended periods, remove the battery to prevent leakage. Store the device in a dry environment, away from direct sunlight and extreme temperatures.
  • Baterijos keitimas: Replace the 9V battery when the power indicator light dims or the device fails to power on.
  • Kalibravimas: Regular calibration by a qualified technician is recommended to maintain measurement accuracy, especially after prolonged use or if accuracy is suspected to have drifted.

9. Problemų sprendimas

ProblemaGalima priežastisSprendimas
Įrenginys neįsijungiaIšsikrovęs arba neteisingai įdėtas akumuliatoriusCheck battery polarity, replace with a new 9V battery.
Netikslūs rodmenys
  • - Improper zero calibration
  • - Tested wire not centered in jaw
  • - External electromagnetic interference
  • - Multiple conductors in jaw
  • - Perform zero calibration before measurement.
  • - Ensure wire is centered.
  • - Move away from strong magnetic fields.
  • - Ensure only one conductor is clampred.
Nėra išėjimo signalo
  • - Loose or faulty output cable connection
  • - Measuring instrument not configured correctly
  • - Check cable connection to both sensor and measuring instrument.
  • - Verify measuring instrument settings (e.g., input type, range).

10. Garantija ir palaikymas

This VTSYIQI ETCR007 AC/DC Clamp Leakage Current Sensor comes with a 1 metų garantija nuo įsigijimo datos, apimanti medžiagų ir gamybos defektus įprasto naudojimo sąlygomis.

For technical support, warranty claims, or service inquiries, please contact the manufacturer:

Prašome išsaugoti pirkimo kvitą kaip pirkimo įrodymą garantijos tikslais.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.