RIGOL DS1054Z

RIGOL DS1054Z Digital Oscilloscope User Manual

Model: DS1054Z

1. Įvadas

The RIGOL DS1054Z is a 4-channel digital oscilloscope offering a 50MHz bandwidth, 1GSa/s real-time sampling rate, and a 24Mpt record length. It incorporates RIGOL's innovative UltraVision technology to provide advanced display and analysis capabilities. This manual provides essential information for the proper setup, operation, and maintenance of your DS1054Z oscilloscope.

2. Pagrindinės savybės

  • 50 MHz bandwidth with 4 analog channels.
  • Up to 1 GSa/s real-time samplingo norma.
  • Standard 12 Mpts memory depth, upgradeable to 24 Mpts.
  • Innovative UltraVision technology for enhanced signal visibility.
  • Waveform capture rate up to 30,000 wfms/s.
  • 7-inch WVGA (800x480) display with multi-level intensity grading.
  • All-in-one signal debugging and emulation.
  • Accelerated analysis and debugging for I2C, RS232, and SPI designs.

3. Produktas baigtasview

This section provides a visual and functional overview of the RIGOL DS1054Z Digital Oscilloscope.

RIGOL DS1054Z Digital Oscilloscope front view

1 pav.: priekis view of the RIGOL DS1054Z Digital Oscilloscope, showing the display, control panel, and input channels.

RIGOL DS1054Z Digital Oscilloscope rear view

2 pav.: galinis view of the RIGOL DS1054Z Digital Oscilloscope, displaying power input, USB, LAN, and auxiliary output ports.

4. Sąranka

  1. Išpakavimas: Carefully remove the oscilloscope and all accessories from the packaging. Verify that all included components (power cord, USB cable, 4x 150MHz probes) are present.
  2. Maitinimo jungtis: Connect the provided power cord to the AC input on the rear panel of the oscilloscope and then to a suitable AC power outlet (100 V~240 V).
  3. Maitinimas: Press the power button located on the front panel to turn on the device. The display will illuminate, and the system will initiate its startup sequence.
  4. Zondo jungtis: Connect the 150MHz probes to the desired input channels (CH1-CH4) on the front panel. Ensure a secure connection.
  5. Initial Probe Compensation: Before taking measurements, it is recommended to perform probe compensation to ensure accurate readings. Refer to the detailed user guide for specific instructions on probe compensation.

5. Naudojimo instrukcijos

This section covers basic operational procedures for the DS1054Z oscilloscope.

5.1 Basic Waveform Acquisition

  1. Prijungimo signalas: Connect the probe to the signal source you wish to measure.
  2. Pasirinkite kanalą: Press the corresponding channel button (e.g., CH1) to enable the channel.
  3. Automatinė sąranka: For a quick display of the waveform, press the AUTO button. The oscilloscope will automatically adjust vertical, horizontal, and trigger settings.
  4. Rankinis reguliavimas: Use the vertical scale (V/div) and position knobs for each channel, and the horizontal scale (s/div) and position knobs to fine-tune the waveform display.

5.2 Trigger Functions

The DS1054Z offers various trigger types to stabilize and capture specific events.

  • Edge Trigger: Triggers on a rising or falling edge of a signal.
  • Pulse Width Trigger: Triggers on pulses of a specified width.
  • Slope Trigger: Triggers on signals with a specific rise or fall time.
  • Video Trigger: Triggers on standard video signals.
  • Pattern Trigger: Triggers when a specific logic pattern is met across multiple channels.
  • Duration Trigger: Triggers on events lasting a specified duration.

To access trigger settings, press the TRIGGER MENU button and use the soft keys and multi-function knob to configure the desired trigger type and parameters.

Oscilloscope screen showing expanded functions and trigger settings

Figure 3: Oscilloscope display illustrating various expanded functions and trigger options, including memory depth settings.

5.3 Waveform Record and Playback

The DS1054Z allows for recording and playback of waveforms, which is useful for capturing transient events or analyzing long signal sequences.

  1. Access Record Function: Navigate to the waveform record menu (refer to the full user manual for exact menu path).
  2. Configure Recording: Set the desired record length and other parameters.
  3. Pradėti / sustabdyti įrašymą: Initiate recording to capture waveforms. Stop recording when the desired data is acquired.
  4. Atkūrimas: Norėdami atkurti, naudokite atkūrimo valdikliusview the recorded waveforms.
Oscilloscope screen showing waveform record and playback interface

Figure 4: Oscilloscope display showing the interface for waveform recording and playback, including controls for starting, stopping, and reviewing captured data.

6. Specifikacijos

ParametrasSpecifikacija
Analoginis dažnių juostos plotis50 MHz
Kanalai4 analoginių kanalų
Max. Real-time Sample Įvertinkite1 GSa/s (1 channel), 500 MSa/s (2 channels), 250 MSa/s (3/4 channels)
Max. Memory Depth12 Mpts (1 channel), 6 Mpts (2 channels), 3 Mpts (3/4 channels); upgradeable
Max. Waveform Capture Rate30,000 XNUMX wfms/s
Vertical Input Impedance1 MΩ ±2 %
Vertical Input Range1 mV/div iki 10 V/div
Horizontalus laiko bazės diapazonas5 ns/div to 50 s/div
Standard Trigger FunctionsEdge, Pulse Width, Slope, Video, Pattern, Duration
Standard Bus DecodeParallel Bus
SąsajosUSB Host & Device, LAN (LXI), AUX Output (Trigger Out, Pass/Fail)
Ekranas7.0-inch WVGA (800x480) TFT LCD, 64 intensity grading levels
Maitinimo šaltinisAC: 100 V~240 V
Matmenys (PxAxG)313.1 mm x 160.8 mm x 122.4 mm
Svorisapytiksliai 3.2 kg
Pridedami priedaiPower cord, USB cable, 4x 150MHz probes

7. Priežiūra

  • Valymas: Regularly clean the exterior of the oscilloscope with a soft, dry cloth. For stubborn dirt, use a cloth lightly dampened with water or a mild, non-abrasive cleaner. Avoid using harsh chemicals or solvents.
  • Vėdinimas: Ensure that the ventilation openings on the device are not obstructed to prevent overheating.
  • Saugykla: When not in use for extended periods, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures.
  • Zondų priežiūra: Handle probes carefully. Avoid bending or stressing the cables excessively. Store probes properly to prevent damage to the tips and connectors.

8. Problemų sprendimas

Šiame skyriuje aptariamos dažniausiai pasitaikančios osciloskopo problemos.

8.1 No Display After Power On

  • Check if the power cord is securely connected to both the oscilloscope and the power outlet.
  • Patikrinkite, ar maitinimo lizdas veikia.
  • Įsitikinkite, kad maitinimo mygtukas yra iki galo nuspaustas.

8.2 Unstable Waveform

  • Adjust the trigger level to a stable point on the waveform.
  • Select an appropriate trigger type for the signal being measured (e.g., Edge trigger for periodic signals).
  • Check the probe connection and ensure it is properly compensated.
  • Verify the input signal's amplitude and frequency are within the oscilloscope's specifications.

8.3 Nerodomas signalas

  • Ensure the input channel is enabled (its corresponding button is lit).
  • Check the probe connection to the signal source and the oscilloscope.
  • Adjust the vertical scale (V/div) to a more sensitive setting.
  • Paspauskite AUTO button to allow the oscilloscope to automatically find the signal.

9. Garantija ir palaikymas

9.1 Informacija apie garantiją

The RIGOL DS1054Z main unit comes with a standard 3 metų garantija from the date of purchase when bought through Amazon. Accessories such as modules, probes, and batteries are covered by a 1 metų garantija. This warranty covers operational defects confirmed by RIGOL Japan. Parallel import products are not eligible for warranty or free support from RIGOL Japan.

In case of a suspected malfunction, after our company confirms that the event is a malfunction, we will provide a replacement with the same product or repair service, or other appropriate response as determined by our company.

9.2 Initial Defect Exchange Policy

Returns are accepted within 14 days of product arrival for initial defects. Return shipping costs for reasons other than operational defects are borne by the purchaser. Questions regarding operational defects or usage are accepted via Amazon email.

9.3 Remontas ir kalibravimas

For repair or calibration services, please contact a domestic authorized RIGOL dealer.

9.4 Papildomi ištekliai ir pagalba

User guides, datasheets, and software for the DS1054Z can be downloaded from the official RIGOL Japan website. If you require an instruction manual earlier, please contact us via Amazon message.