1. Įvadas
This manual provides essential information for the safe and efficient operation of your Voltcraft VLP-1602 USB Laboratory Power Supply. The VLP-1602 is a versatile, adjustable power supply designed for laboratory and development applications, offering precise control over voltage ir srovė.
Pagrindinės funkcijos:
- Electronic linear regulation for stable output without ripple.
- Three independent outputs.
- Overvoltage apsauga (OVP).
- Integrated USB test and development socket for stressing connected USB devices.
- Reguliuojamas tūristage from 0 to 60 V and current from 0.01 to 1.5 A.
2. Saugos informacija
Prieš naudodami įrenginį, perskaitykite ir supraskite visas saugos instrukcijas. Nesilaikant šių instrukcijų, gali kilti elektros smūgis, gaisras arba sunkūs sužalojimai.
- Elektros sauga: Always connect the power supply to a grounded outlet. Do not operate the device with damaged power cords or if the casing yra atidarytas.
- Vėdinimas: Užtikrinkite tinkamą vėdinimą aplink įrenginį. Neužblokuokite ventiliacijos angų.
- Aplinka: Use the device in a dry environment, away from moisture, dust, and direct sunlight.
- Apsauga nuo perkrovos: Neviršykite nurodyto tūriotage and current ratings. The device includes Overvoltage apsauga (OVP).
- Aptarnavimas: Visus techninės priežiūros darbus patikėkite kvalifikuotiems darbuotojams. Nebandykite taisyti įrenginio patys.
- Vaikai: Prietaisą laikykite vaikams nepasiekiamoje vietoje.
3. Sąranka
3.1 Išpakavimas ir patikrinimas
Carefully remove the power supply from its packaging. Inspect the unit for any signs of damage that may have occurred during transit. If any damage is found, do not operate the device and contact your supplier.
3.2 Prijungimas prie elektros tinklo
- Įsitikinkite, kad priekiniame skydelyje esantis maitinimo jungiklis yra padėtyje „OFF“ (išjungta).
- Connect the provided power cord to the AC inlet on the rear panel of the power supply.
- Plug the other end of the power cord into a standard 230V AC, 50Hz grounded electrical outlet.

3.3 Pradinis įjungimas
After connecting the power cord, switch the power supply ON using the main power switch on the front panel. The display should illuminate, indicating the device is ready for operation.
4. Naudojimo instrukcijos
4.1 Priekinio skydelio viršusview

The front panel features digital displays for voltage and current, control knobs for precise adjustment, and multiple output terminals.
4.2 Garsumo reguliavimastage and Current (Output A)
- Connect your load to the main output terminals (Output A). Use the red terminal for positive (+) and the black terminal for negative (-). The yellow terminal is for ground.
- Turn the "VOLT" knob to set the desired output voltage. The digital display will show the set voltage.
- Turn the "AMPERE" knob to set the desired current limit. This acts as a current limiter to protect your circuit.
- The "C-LIMIT" indicator will illuminate if the current limit is reached.
- The "OVP" (Overvoltage Protection) indicator will illuminate if an overvoltage condition occurs.

4.3 Using the USB Outputs (Output B-USB)
The VLP-1602 includes dedicated USB outputs for testing and development purposes. These outputs can be used to stress connected USB devices.
- Connect your USB device to one of the USB-B1 or USB-B2 ports.
- Use the "MODE" switch to select the desired USB output mode (e.g., 4.8-5.2V, 4.5-4.7V, Normal).
- The "ADJ" knob allows for fine adjustment of the USB output voltage within the selected mode.
- Refer to the labels near the USB ports for specific voltage and current ratings (e.g., USB-B1: 5V/2A, USB-B2: 12V/0.5A).
5. Priežiūra
5.1 Valymas
To clean the exterior of the power supply, use a soft, damp šluoste. Nenaudokite abrazyvinių valiklių ar tirpiklių. Prieš valydami įsitikinkite, kad įrenginys išjungtas ir atjungtas nuo elektros tinklo.
5.2 Saugiklio keitimas
If the power supply does not turn on, check the fuse located on the rear panel near the AC inlet.
- Atjunkite maitinimo laidą nuo kintamosios srovės lizdo.
- Use a flat-head screwdriver to open the fuse holder.
- Replace the blown fuse with a new fuse of the same type and rating (T 1.6A / 250V).
- Close the fuse holder securely.
Įspėjimas: Always replace fuses with the specified type and rating to prevent damage to the unit or risk of fire.
6. Problemų sprendimas
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| Įrenginys neįsijungia. | No power from outlet, power cord disconnected, blown fuse. | Check power outlet, ensure power cord is securely connected, replace fuse (see Section 5.2). |
| Nėra išėjimo tūriotage/dabartinis. | Output terminals not connected, voltage/current knobs set to zero, OVP/OCP triggered. | Ensure load is properly connected, adjust voltage/current knobs, check for OVP/OCP indicators and reset if necessary. |
| Išėjimo tūristage/current is unstable. | Poor connection, faulty load, internal issue. | Check all connections, test with a different load. If problem persists, contact support. |
| Overvoltage Protection (OVP) indicator is on. | Išėjimo tūristage exceeded a safe limit. | Reduce the set voltage or check the load for issues. Power cycle the unit to reset OVP. |
7. Specifikacijos
| Parametras | Vertė |
|---|---|
| Modelio numeris | VLP-1602 |
| Gamintojas | VOLTRAFTAS |
| Išėjimas ttage (pagrindinis) | 0–60 V |
| Output Current (Main) | 0.01–1.5 A |
| Išėjimų skaičius | 3 (Main + 2 USB) |
| Išėjimo galia | 123 W |
| Įvesties tomastage | 230 voltų |
| Matmenys (I x P x A) | 27 x 26 x 11.5 cm |
| Svoris | 6.6 kilogramo |
| Ypatingos savybės | High-precision multi-speed potentiometer, USB development port |
| Jungties tipas | USB |
8. Garantija ir palaikymas
8.1 Informacija apie garantiją
The Voltcraft VLP-1602 USB Laboratory Power Supply comes with a 1-year availability of spare parts. For specific warranty terms and conditions, please refer to the documentation provided with your purchase or contact your retailer.
8.2 Pagalba klientams
For technical assistance, troubleshooting, or service inquiries, please contact Voltcraft customer support or your authorized dealer. Please have your model number (VLP-1602) and purchase information ready when contacting support.