1. Įvadas
The Apera Instruments Value Series EC850 Portable Conductivity Meter Kit is engineered for precise conductivity and TDS measurements in various field applications. Its robust design and practical features ensure reliable performance and ease of use for professionals.
2. Produktas baigtasview
2.1 Pagrindinės savybės
- Reliable conductivity/TDS measurements for quick and easy analysis.
- IP57 rugged structure, ideal for field use, with a foldable stand for benchtop operation.
- Automatic 1- to 3-point calibration, with included calibration solutions.
- Built-in temperature sensor for automatic temperature compensation (ATC).
- Self-diagnosis function to ensure proper calibration and assist with common issues.
2.2 Kas yra dėžutėje
- Apera Instruments EC850 Portable Conductivity Meter Kit
2.3 Produkto komponentai

Figure 1: The EC850 meter with its conductivity probe, displaying a measurement of 1413 µS at 25.0°C. The meter is waterproof and features clear buttons for calibration, mode, setup, and power.

Figure 2: The EC850 meter shown with its integrated kickstand extended, allowing for convenient benchtop use. The display shows a reading of 1413 µS and 25.0°C.

3 pav. Iš arti view of the conductivity probe's connector, designed for secure attachment to the EC850 meter.

Figure 4: The complete EC850 Portable Conductivity Meter Kit neatly organized within its durable carrying case, including the meter, probe, and calibration solutions.

5 pav. Išsamus view of the conductivity probe tip, showing the electrodes responsible for accurate measurements.
3. Sąranka
3.1 Pirminė apžiūra
Upon receiving your EC850 kit, carefully inspect all components for any signs of damage during transit. Ensure all listed items in "What's in the Box" are present.
3.2 Akumuliatoriaus įdėjimas
Locate the battery compartment on the back of the meter. Insert the required batteries (typically AA or AAA, refer to the meter's battery compartment for specific type and polarity) ensuring correct orientation. Close the compartment securely.
3.3 Zondo jungtis
Connect the conductivity probe to the meter's input port. Ensure the connection is firm and secure to prevent measurement inaccuracies.
3.4 Pradinis kalibravimas
For optimal accuracy, perform an initial calibration. The EC850 supports 1- to 3-point automatic calibration. Refer to the included quick start guide for detailed steps on using the provided calibration solutions.
4. Naudojimo instrukcijos
4.1 Pagrindinis matavimas
- Įjunkite matuoklį paspausdami maitinimo mygtuką.
- Rinse the probe thoroughly with distilled or deionized water before each measurement.
- Panardinkite zondą į sample solution, ensuring the sensor area is fully submerged.
- Allow the reading to stabilize on the display. The meter will show conductivity/TDS and temperature.
- Užrašykite matavimą.
- Rinse the probe again after use.
4.2 Ekrano rodmenų supratimas
The EC850 display shows the primary measurement (Conductivity in µS/cm or mS/cm, or TDS in ppm) and the temperature in °C. The meter automatically compensates for temperature variations (ATC) to provide accurate readings.
4.3 Self-Diagnosis
The meter features a self-diagnosis function that can alert you to common issues such as calibration errors or probe problems. Follow the on-screen prompts or consult the troubleshooting section for guidance.
5. Priežiūra
5.1 Zondo valymas
Regularly clean the conductivity probe to prevent buildup that can affect accuracy. Rinse the probe with distilled water after each use. For stubborn deposits, refer to the detailed cleaning instructions in the full manual or Apera Instruments' support resources.
5.2 Saugykla
When not in use, store the probe in its protective cap with a small amount of storage solution (or appropriate calibration solution if storage solution is unavailable). Store the meter and probe in a cool, dry place, preferably in its original carrying case.
5.3 Akumuliatoriaus keitimas
Replace batteries when the low battery indicator appears on the display. Ensure the meter is turned off before opening the battery compartment. Dispose of old batteries responsibly.
6. Problemų sprendimas
If you encounter issues with your EC850 meter, consult the following common problems and solutions:
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| Netikslūs rodmenys | Dirty probe, expired calibration, incorrect calibration. | Clean the probe, recalibrate the meter with fresh solutions, ensure correct calibration procedure. |
| Matuoklis neįsijungia | Išsikrovusios baterijos, neteisingas baterijų įdėjimas. | Replace batteries, check battery polarity. |
| Klaidingi rodmenys | Air bubbles on probe, damaged probe, electrical interference. | Gently tap the probe to dislodge bubbles, inspect probe for damage, move away from strong electrical fields. |
For more complex issues or persistent problems, please contact Apera Instruments customer support.
7. Specifikacijos
| Atributas | Detalė |
|---|---|
| Gaminio matmenys | 13.78 x 10.63 x 3.15 colio; 2.6 svaro |
| Prekės modelio numeris | AI5512 |
| Gamintojas | Apera instrumentai |
| ASIN | B083RC3441 |
| Pirmas prieinamas | 11 m. sausio 2020 d |
| Apsaugos nuo patekimo (IP) įvertinimas | IP57 (atsparus vandeniui) |
| Kalibravimas | Automatic 1- to 3-point |
| Temperatūros kompensavimas | Automatic (ATC) |
8. Garantija ir palaikymas
Apera Instruments products are backed by a manufacturer's warranty. For detailed information regarding your product's warranty period, terms, and conditions, please visit the official Apera Instruments websvetainėje arba susisiekite tiesiogiai su jų klientų aptarnavimo tarnyba.
For technical assistance, troubleshooting, or to purchase replacement parts and accessories, please reach out to Apera Instruments customer service. Contact information can typically be found on their official websvetainėje arba produkto pakuotėje.
Gamintojas: Apera instrumentai
Websvetainė: www.aperainst.com
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.