1. Įvadas

This manual provides detailed instructions for the setup, operation, maintenance, and troubleshooting of the Assistive Technology Services Life Guardian Medical Alarm Emergency Alert Phone System HD700. This system is designed to provide an independent emergency alert solution, utilizing a standard home phone line to contact pre-programmed individuals or emergency services without monthly monitoring fees.

2. Pakuotės turinys

Patikrinkite, ar jūsų pakuotėje yra visi toliau išvardyti daiktai:

  • HD700 Base Unit
  • Wrist Panic Button
  • Necklace Panic Button
  • Maitinimo adapteris
  • Telefono linijos laidas
  • CR123A Battery (pre-installed or included separately for base unit)
HD700 Medical Alarm System components

2.1 vaizdas: Baigtaview of the HD700 base unit, wrist panic button, and necklace panic button.

3. Sąrankos instrukcijos

Follow these steps to set up your HD700 system:

  1. Prijunkite maitinimą: Plug the power adapter into the HD700 base unit and then into a standard electrical outlet.
  2. Prisijungimas prie telefono linijos: Connect one end of the telephone line cord to the 'LINE' port on the HD700 base unit and the other end to your home phone wall jack. If you have an existing phone, connect it to the 'PHONE' port on the HD700 base unit. The system requires a standard landline phone connection.
  3. Įdėkite akumuliatorių: Ensure the CR123A battery is correctly installed in the base unit. This battery provides backup power during outages.
  4. Record Emergency Message: Press and hold the 'RECORD' button on the base unit. Speak your personalized emergency message clearly into the microphone for up to 7 seconds. A typical message might be: "This is [Your Name], I need help. Please respond." Release the 'RECORD' button when finished.
  5. Program Phone Numbers: The system can store up to three emergency contact numbers. Refer to the detailed programming section in the full manual for specific key sequences to enter and save each number. It is recommended to program 911 as the third number.
  6. Bandymo sistema: After programming, perform a test by pressing one of the panic buttons. Verify that the system dials the programmed numbers and plays your recorded message. Ensure the recipient can press a key to establish two-way communication.
HD700 Medical Alarm System with power adapter and phone cables

Image 3.1: The HD700 system showing the base unit, panic buttons, power adapter, and phone cables for connection.

4. Naudojimo instrukcijos

The HD700 system is designed for simple operation during an emergency.

4.1 Activating an Emergency Alert

To activate an emergency alert, press and hold the large red button on either the wrist panic button or the necklace panic button for approximately 2 seconds. The base unit will then initiate the emergency call sequence.

Close-up of the wrist panic button with red SOS button

Image 4.1: The wrist panic button, featuring a prominent red SOS button for emergency activation.

Close-up of the necklace panic button with blue button

Image 4.2: The necklace panic button, designed for easy access and activation.

4.2 Emergency Call Sequence

  • Upon activation, the HD700 base unit will sequentially dial the pre-programmed phone numbers.
  • When a call is answered, the system plays your personalized emergency message.
  • The recipient must press any key on their phone to acknowledge the call and open two-way communication through the base unit's speakerphone.
  • If no key is pressed, or if the line is busy/unanswered, the system will hang up and dial the next programmed number in sequence.
  • The panic buttons have a range of approximately 100 feet from the base unit.

4.3 Panic Button Features

  • Wrist Panic Button: This button is water-resistant, allowing it to be worn during showering or bathing. It is also pacemaker safe.
  • Necklace Panic Button: This button is not waterproof and should not be exposed to water. It is also pacemaker safe.

5. Priežiūra

5.1 Akumuliatoriaus keitimas

The HD700 base unit uses one CR123A battery for backup power. Replace this battery periodically or when the low battery indicator illuminates. Refer to the base unit's battery compartment for specific replacement instructions. Panic button batteries are typically long-lasting and may require professional replacement or a new unit if depleted.

5.2 Valymas

Clean the base unit and panic buttons with a soft, dry cloth. Do not use abrasive cleaners or immerse any part of the system in water (except for the water-resistant wrist button as specified).

5.3 Reguliarus testavimas

It is recommended to test the system monthly to ensure proper functionality. This includes verifying that the panic buttons activate the base unit, the system dials the correct numbers, and two-way communication can be established.

6. Problemų sprendimas

  • System Not Dialing:
    • Ensure the base unit is powered on and connected to a working phone line.
    • Verify that emergency numbers are correctly programmed.
    • Check for a dial tone on the phone line.
  • Poor Audio Quality During Two-Way Communication:
    • Ensure the microphone was close to your mouth when recording the emergency message.
    • Adjust the volume on the base unit if applicable.
    • Ensure there are no obstructions near the base unit's speaker or microphone.
  • Klaidingi pavojaus signalai:
    • Ensure panic buttons are stored or worn in a way that prevents accidental pressing.
  • No Direct 911 Call:
    • The system dials pre-programmed numbers sequentially. To contact 911, it must be programmed as one of the emergency contact numbers.
    • Note that if using a VOIP phone service, 911 calls may not automatically provide your exact location to the operator.

7. Specifikacijos

Prekės ženklasAssistive Technology Services
ModelisHD700
Maitinimo šaltinisAdapteris
Baterijų skaičius1 CR123A (pridedama)
Baterijos aprašymasLičio
Kontrolės metodasPalieskite
Montavimo tipasStalviršio laikiklis
Maximum Range (Panic Buttons)100 pėdų
Prekės svoris1.26 svaro
Pakuotės matmenys12.91 x 5.94 x 2.36 colio

8. Garantija ir palaikymas

For information regarding product warranty or technical support, please contact Assistive Technology Services directly. Refer to the product packaging or the manufacturer's websvetainė, kurioje pateikiami naujausi kontaktiniai duomenys.

© 2023 Pagalbinių technologijų paslaugos. Visos teisės saugomos.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.