Simon F1090397030

SIMON Series 10 Double Switch-Commutator Instruction Manual

Modelis: F1090397030

1. Produktas baigtasview

The SIMON Series 10 Double Switch-Commutator is designed to control two independent light points from a single location. It can function as a standard ON/OFF switch or as a commutator, redirecting electrical current to connect different circuits. This unit is supplied as a pre-assembled component, including the mechanism, cover, and frame, to simplify the installation process. Its minimalist design with straight lines allows for seamless integration into various interior spaces.

SIMON Series 10 Double Switch-Commutator, front view

1 pav.: priekis view of the SIMON Series 10 Double Switch-Commutator.

2. Saugos įspėjimai

  • Elektros pavojus: Installation should only be performed by a qualified electrician or a person with adequate knowledge of electrical systems. Always disconnect the main power supply before beginning any installation or maintenance work.
  • Do not drill into the device or expose it to fire.
  • This product is designed for indoor use (IP20 rating). Do not install in environments with high humidity or direct water exposure.
  • Įsitikinkite, kad visi laidų sujungimai yra tvirti ir atitinka vietinius elektros kodeksus.
  • Under no circumstances shall Simon be liable for any indirect, special, incidental, punitive, or consequential damages of any kind arising from improper installation or misuse of the product.

3. Sudedamosios dalys

The SIMON Series 10 Double Switch-Commutator package includes the following components:

  • Double Switch-Commutator Mechanism
  • Decorative Cover (White)
  • Montavimo rėmas
SIMON Series 10 Double Switch-Commutator in packaging

Figure 2: Product as supplied in its packaging.

4. Sąranka ir diegimas

The SIMON Series 10 Double Switch-Commutator is designed for straightforward installation. The metallic frame provides robustness, while the polypropylene frame offers flexibility during mounting.

4.1. Laidų schema ir jungtys

This device uses screw terminals for secure wiring connections. Refer to the diagram below for proper wiring. If you are unfamiliar with electrical wiring, consult a professional electrician.

Sprogo view of SIMON Series 10 Double Switch-Commutator showing mechanism and frame

3 pav.: sprogo view showing the mechanism, frame, and cover assembly.

  1. Paruošimas: Ensure the main power supply to the circuit is turned OFF at the consumer unit/fuse box.
  2. Mechanizmo montavimas: Place the switch mechanism into the wall box. The flexible polypropylene frame aids in positioning.
  3. Laidai: Connect the electrical wires to the screw terminals. For a double switch-commutator, typically you will have a common phase wire (L) and two switched phase wires (L1, L2) for each light point, along with neutral and earth connections if applicable to the installation type. Ensure all connections are tight.
  4. Apsauga: Use the metallic claws to firmly secure the mechanism to the wall box.
  5. Attaching the Cover and Frame: Snap the decorative cover and frame onto the mechanism until they are securely in place.
  6. Galutinis patikrinimas: Once installation is complete, restore power and test the functionality of both switches.

5. Naudojimo instrukcijos

The SIMON Series 10 Double Switch-Commutator features two independent rocker switches. Each switch can control a separate light point or circuit.

  • Jungiklio funkcija: Press the top part of the rocker to turn the connected light/circuit ON. Press the bottom part to turn it OFF.
  • Commutator Function: When configured as a commutator, pressing the rocker will switch the current path between two different conductors, allowing control of a light from multiple locations (e.g., at the top and bottom of a staircase).

6. Priežiūra

The SIMON Series 10 Double Switch-Commutator requires minimal maintenance.

  • Valymas: To clean the surface, gently wipe with a soft, dry cloth. For stubborn marks, use a slightly damp šluoste su švelniu muilu, tada nedelsdami nusausinkite.
  • Venkite: Nenaudokite abrazyvinių valiklių, tirpiklių ar stiprių cheminių medžiagų, nes jos gali pažeisti apdailą.
  • Patikra: Periodically check for any loose connections or signs of wear. If any damage is observed, disconnect power and replace the unit.

7. Problemų sprendimas

If the switch-commutator is not functioning as expected, consider the following:

  • Nėra galios: Check the main power supply and the circuit breaker. Ensure power is restored to the circuit.
  • Šviesa neįsijungia/neišsijungia: Verify that the light bulb is functional. Check all wiring connections at the switch and the light fixture for looseness or incorrect wiring.
  • Operacija su pertraukomis: This could indicate a loose connection. Disconnect power and re-check all screw terminals.
  • Difficulty in Wiring: The wiring diagram on the mechanism can be complex for some users. If you encounter difficulties, it is recommended to consult a qualified electrician.

8. Specifikacijos

Modelio numerisF1090397030
Prekės ženklasSimonas
TipasDouble Switch-Commutator
ttage230 V (DC)
Dabartinis reitingas10 Amperes
Grandinės tipas2 krypčių
Kontakto tipasPaprastai atidarytas
Terminalo tipasVaržtas Clamp
MedžiagaMetalas, polipropilenas
SpalvaBaltas
Matmenys (I x P x A)8.4 x 8.4 x 4.5 cm
Svoris86 g
Veikimo režimasĮJUNGTI IŠJUNGTI
IP reitingasIP20 (naudoti patalpose)

9. Garantija ir palaikymas

For warranty information or technical support, please contact Simon customer service. Keep your purchase receipt as proof of purchase.

Visit the official Simon website for additional resources, FAQs, or to locate authorized service centers.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.