Įvadas
This manual provides essential information for the safe and efficient operation of your APC Smart-UPS SMT3000C 3000VA Uninterruptible Power Supply. Please read this manual thoroughly before installation and use.
Svarbios saugos instrukcijos
Please read and follow all safety instructions carefully to prevent injury or damage to the unit. Retain this manual for future reference.
- Elektros sauga: Connect the UPS to a grounded outlet only. Do not remove the grounding prong.
- Baterijos sauga: Batteries can present a risk of electrical shock and high short-circuit current. Observe proper polarity when connecting batteries.
- Montavimas: Install the UPS indoors in a controlled environment, free from excessive dust, corrosive fumes, and conductive contaminants.
- Aptarnavimas: Refer all servicing to qualified service personnel. There are no user-serviceable parts inside the UPS.
Pakuotės turinys
Verify that all items listed below are included in your package. If any items are missing or damaged, contact your dealer or APC.
- APC Smart-UPS SMT3000C Unit
- PowerChute Business Edition Software CD
- RS-232 kabelis
- USB kabelis
- Ethernet kabelis
- Vielos raiščiai
- Valymo rinkinys

1 paveikslas: APC Smart-UPS SMT3000C unit shown with all included accessories: RS-232 cable, USB cable, Ethernet cable, wire ties, and a cleaning kit.
Produktas baigtasview
The APC Smart-UPS SMT3000C is a Line Interactive Uninterruptible Power Supply designed to provide reliable power protection for your electronic equipment. It features Automatic Voltage Regulation (AVR) and SmartConnect for remote monitoring.
Priekinis skydelis

2 paveikslas: Priekyje view of the APC Smart-UPS SMT3000C, displaying the control panel and LCD screen for status monitoring.
Galinis skydelis
The rear panel provides all necessary connections for input power, protected outlets, and communication ports.

3 paveikslas: Galinis view of the APC Smart-UPS SMT3000C, highlighting the NEMA 5-30P input, (8) NEMA 5-15R outputs, (2) NEMA 5-20R outputs, communication ports (RS-232, USB, Ethernet), and a circuit breaker.
- Įvesties galia: NEMA 5-30P
- Išvesties lizdai: (8) NEMA 5-15R, (2) NEMA 5-20R
- Ryšio prievadai: RS-232, USB, Ethernet (for SmartConnect)
- Grandinės pertraukiklis: Apsauga nuo perkrovos
Sąranka
1. Įdėjimas
Place the UPS on a flat, stable surface in a cool, dry, and well-ventilated area. Ensure adequate clearance around the unit for proper airflow. Avoid direct sunlight, heat sources, and excessive moisture.
2. Baterijos prijungimas
The UPS is shipped with the internal battery disconnected for safety. Follow these steps to connect the battery:
- Remove the front bezel of the UPS.
- Locate the battery connector.
- Firmly push the battery connector together until it clicks into place.
- Pakeiskite priekinį dangtelį.
3. Įrangos prijungimas
Connect your critical equipment (computers, servers, network devices) to the UPS output outlets. Ensure that the total load does not exceed the UPS capacity (2700W).
- Baterijos atsarginis maitinimas ir nuo viršįtampių apsaugoti lizdai: Šie lizdai tiekia energiją akumuliatoriams darbo metu.tages and surge protection. Connect critical equipment here.
4. Prijungimas prie elektros tinklo
Plug the UPS power cord (NEMA 5-30P) into a dedicated, grounded 120V wall outlet. Avoid using extension cords or surge strips with the UPS input.
5. Pradinis įjungimas
Press the power button on the front panel to turn on the UPS. The LCD display will illuminate, and the UPS will perform a self-test. Allow the UPS to charge for at least 24 hours before relying on it for extended battery backup.
6. SmartConnect Setup
The APC SmartConnect feature allows for remote monitoring of your UPS. Connect an Ethernet cable from the UPS SmartConnect port to your network. Follow the instructions provided with the SmartConnect service to register your device and enable remote monitoring, automatic notifications, and firmware updates.
UPS valdymas
Maitinimo įjungimas/išjungimas
- Norėdami įjungti: Press and hold the power button on the front panel until the display illuminates.
- Norėdami išjungti: Paspauskite ir palaikykite maitinimo mygtuką, kol ekranas išsijungs.
Automatinis ttage reglamentas (AVR)
UPS funkcija – automatinis garsumo reguliavimas.tage reguliavimas (AVR), kuris automatiškai ištaiso nedidelį garsumątage fluctuations (sags and surges) without using battery power. This helps to preserve battery life and ensures a stable power supply to connected equipment.
Veiklos trukmės informacija
The APC Smart-UPS SMT3000C provides varying runtimes depending on the connected load:
- 50W Load: Maždaug 563 minučių
- 100W Load: Maždaug 330 minučių
- 200W Load: Maždaug 172 minučių
- 300W Load: Maždaug 112 minučių
- 400W Load: Maždaug 81 minučių
- 500W Load: Maždaug 63 minučių
- 600W Load: Maždaug 51 minučių
- 700W Load: Maždaug 42.2 minučių
- 800W Load: Maždaug 35.7 minučių
- 900W Load: Maždaug 30.6 minučių
- 1000W Load: Maždaug 26.7 minučių
- 1350W (Half Load): Maždaug 17.5 minučių
- 1400W Load: Maždaug 16.6 minučių
- 1600W Load: Maždaug 13.5 minučių
- 1800W Load: Maždaug 11.2 minučių
- 2000W Load: Maždaug 9.4 minučių
- 2500W Load: Maždaug 6.1 minučių
- 2700W (Full Load): Maždaug 5.7 minučių
„PowerChute“ verslo versijos programinė įranga
Install the PowerChute Business Edition software on your connected computer to enable safe system shutdown during extended power outages, monitor UPS status, and configure various settings. Connect the UPS to your computer using the provided USB or RS-232 cable.
Priežiūra
Akumuliatoriaus priežiūra
The UPS batteries are designed for a specific lifespan. Factors such as ambient temperature, number of discharge cycles, and discharge depth affect battery life. Replace batteries when the UPS indicates a battery fault or when runtime significantly decreases.
- Perform regular self-tests (via the UPS display or PowerChute software) to assess battery health.
- Avoid operating the UPS in environments with high temperatures, as this can shorten battery life.
Valymas
Regularly clean the exterior of the UPS with a soft, dry cloth. Use the provided cleaning kit for gentle cleaning. Ensure the UPS is powered off and disconnected from utility power before cleaning. Do not use liquid or aerosol cleaners directly on the unit.
Trikčių šalinimas
This section provides solutions to common issues you may encounter with your UPS. For more complex problems, contact APC technical support.
- UPS neįsijungia: Ensure the battery is properly connected and the UPS is plugged into a live wall outlet. Check the input circuit breaker.
- UPS beeps continuously: This usually indicates an overload condition or a low battery. Reduce the connected load or allow the battery to charge.
- Prijungta įranga praranda energiją išjungimo metu.tage: The UPS may be overloaded, or the battery may be depleted or faulty. Verify the load and battery status.
- „SmartConnect“ neprisijungia: Ensure the Ethernet cable is securely connected and your network settings allow communication. Check the SmartConnect portal for device registration status.
Specifikacijos
| Funkcija | Detalė |
|---|---|
| Modelio numeris | SMT3000C |
| Talpa | 3000 2700 VA / XNUMX W |
| Įvesties tomastage | 120 voltų |
| Įvesties jungtis | NEMA 5-30P |
| Išvesties jungtys | (8) NEMA 5-15R, (2) NEMA 5-20R |
| Baterijos tipas | Švino rūgštis |
| Gaminio matmenys | 6 x 6 x 6 colio |
| Prekės svoris | 124.9 svaro |
| Spalva | Juoda |
| „Energy Star“ sertifikatas | Taip |
Garantija ir palaikymas
APC provides a standard warranty for this product. For detailed warranty information, please refer to the warranty card included with your product or visit the official APC website. For technical support, product registration, or service inquiries, please contact APC customer support through their official channels.
The APC SmartConnect feature is free during the standard warranty period of the UPS, providing advanced support services and remote monitoring.