Einaus Einaus-WT03

Einaus 2-Channel Universal Wireless Radio Receiver Instruction Manual

Model: Einaus-WT03

1. Įvadas

This instruction manual provides detailed guidance for the installation, setup, and operation of your Einaus 2-Channel Universal Wireless Radio Receiver. This device is designed for wireless control of various electrical appliances, including heaters, ventilation systems, air conditioners, pumps, barriers, lighting, multi-channel electric doors and windows, electronic locks, garage doors, lifting equipment, and industrial automation systems. Please read this manual thoroughly before use to ensure proper function and safety.

2. Pakuotės turinys

Atidarius pakuotę, joje turėtų būti šie komponentai:

  • 1 x Receiver module with protective casing
  • 2 x Remote controls (each with battery installed)

Jei trūksta kokių nors komponentų arba jie pažeisti, susisiekite su klientų aptarnavimo tarnyba.

3. Specifikacijos

ParametrasVertė
Jungiklio tipasRemote control relay output
Kanalai2 kanalai
Veiklos ttageDC 12-48V
Veikimo dažnis433 MHz
Priėmimo jautrumas> -104 dBm
Maksimali darbinė srovė10 A
Darbinė temperatūra-20 °C iki 65 °C
Jungties tipasSraigtinis terminalas
Kontaktinė medžiagaVaris
Kontakto tipasNormaliai atidarytas (NO) / Normaliai uždarytas (NC)
Montavimo tipasPaviršinis montavimas
Galios įvertinimas12 vatų
Ritė Voltage12 volto (DC)
Minimalus perjungimo tūristage12 volto (DC)
Terminalų skaičius2
AtitiktisCE

4. Produktas baigtasview

Einaus 2-Channel Universal Wireless Radio Receiver module inside its protective casing.
Figure 4.1: Receiver module inside its protective casing.
Į viršų view of the Einaus 2-Channel Universal Wireless Radio Receiver circuit board, showing relays and terminals.
4.2 paveikslas: viršuje view of the receiver circuit board.
Kampuotas view of the Einaus 2-Channel Universal Wireless Radio Receiver circuit board, highlighting components and learning buttons.
4.3 pav.: Kampinis view of the receiver circuit board.

5. Sąranka ir susiejimas

5.1. Clearing Existing Codes

To clear all previously paired remote controls from the receiver's memory:

  1. Raskite Mokymosi mygtukas on the receiver board.
  2. Paspauskite ir palaikykite Mokymosi mygtukas until the indicator light turns off. This indicates that all stored codes have been successfully cleared.

5.2. Pairing a Remote Control (Learning Mode)

To pair a new remote control with the receiver:

  1. Paspauskite Mokymosi mygtukas on the receiver once. The indicator light will flash once and then turn off. This signifies the receiver is ready to learn a new code in Momentary mode.
  2. Immediately press any button on your remote control. The indicator light on the receiver will flash to confirm successful pairing.
  3. Repeat for additional remote controls if needed.

6. Veikimo režimai

The receiver supports several operating modes, which determine how the relay responds to remote control input. You can set the desired mode by pressing the Režimo mygtukas on the receiver board a specific number of times.

6.1. Momentary Mode

In Momentary mode, the relay activates only as long as the remote control button is pressed. Releasing mygtukas išjungia relę.

  • Nustatymas: Paspauskite Režimo mygtukas once. The indicator will flash once and turn off.

6.2. Latch Mode

In Latch mode, one button press activates the relay, and another distinct button press is required to deactivate it.

  • Nustatymas: Paspauskite Režimo mygtukas twice. The indicator will flash twice and turn off.

6.3. Perjungti režimą

In Toggle mode, a single button press activates the relay, and pressing the same button again deactivates it. It acts like a flip-flop switch.

  • Nustatymas: Paspauskite Režimo mygtukas three times. The indicator will flash three times and turn off.

6.4. 5-Second Delay Mode

This mode activates the relay for a fixed duration of 5 seconds after a button press, then automatically deactivates it.

  • Nustatymas: Paspauskite Režimo mygtukas four times. The indicator will flash four times and turn off.

7. Elektros instaliacijos schemos

The following diagrams illustrate common wiring configurations for the Einaus 2-Channel Universal Wireless Radio Receiver. Always ensure power is disconnected before making any wiring changes.

Wiring diagram for general 12-48V DC output, showing connections for two independent loads.
Figure 7.1: General 12-48V DC Output Wiring Diagram. This diagram shows how to connect two separate DC loads to the receiver's relay outputs.
Wiring diagram for a DC 12-48V motor, illustrating connections for motor control.
Figure 7.2: Wiring Diagram for DC 12-48V Motor. This diagram details connecting a DC motor for control via the receiver.
Wiring diagram for AC output, showing connections for an AC load with 12-36V DC power input to the receiver.
Figure 7.3: AC Output Wiring Diagram. This diagram shows how to connect an AC load, with the receiver powered by 12-36V DC.
Example of the receiver wired to LED light strips, demonstrating a practical application.
7.4 pav.: Taikymo pavyzdysample: Receiver wired to LED light strips.

8. Priežiūra

The Einaus Wireless Radio Receiver is designed for reliable operation with minimal maintenance. Follow these guidelines to ensure longevity:

  • Valymas: Keep the receiver free from dust and debris. Use a soft, dry cloth for cleaning. Do not use liquid cleaners or solvents.
  • Aplinka: Ensure the receiver is installed in a dry environment, away from direct moisture, extreme temperatures, and corrosive substances.
  • Maitinimas: Use a stable power supply within the specified voltage diapazonas (DC 12-48V).
  • Nuotolinio valdymo pulto baterijos: Replace remote control batteries when their range decreases or they stop responding.

9. Problemų sprendimas

If you encounter issues with your receiver, refer to the following troubleshooting steps:

  • Imtuvas neatsako:
    • Check the power supply to the receiver. Ensure it is within the 12-48V DC range and properly connected.
    • Patikrinkite, ar nuotolinio valdymo pulto baterijos nėra išsekusios.
    • Ensure the remote control is paired correctly. Try re-pairing the remote control (refer to Section 5.2).
    • Check for strong radio interference in the vicinity.
  • Trumpas veikimo diapazonas:
    • Pakeiskite nuotolinio valdymo pulto baterijas.
    • Ensure there are no significant obstructions (thick walls, metal structures) between the remote and the receiver.
    • Avoid installing the receiver near large metal objects or other radio-emitting devices.
  • Relė neįsijungia / neišsijungia:
    • Check the wiring to the load. Ensure connections are secure and correct according to the wiring diagrams (Section 7).
    • Verify the operating mode is set as intended (Section 6).
    • Ensure the load current does not exceed the maximum 10A rating.

Jei problema išlieka atlikus šiuos veiksmus, susisiekite su klientų aptarnavimo tarnyba.

10. Garantija ir palaikymas

This Einaus product is covered by a standard manufacturer's warranty against defects in materials and workmanship. Please refer to your purchase documentation for specific warranty terms and duration.

Dėl techninės pagalbos, trikčių šalinimo ar garantinių pretenzijų kreipkitės tiesiogiai į pardavėją arba gamintoją. Išsaugokite pirkimo kvitą kaip pirkimo įrodymą.

© 2026 Einaus. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.