1. Įvadas
This manual provides comprehensive instructions for the safe installation, efficient operation, and proper maintenance of your OLTEANP 2000W Sump Pump Battery Backup System. This system is designed to provide uninterrupted power to your sump pump during electrical outages, ensuring your basement remains dry. Please read this manual thoroughly before installation and operation to ensure optimal performance and safety.
2. Saugos informacija
- Always disconnect the system from all power sources before performing any maintenance or installation.
- Užtikrinkite tinkamą vėdinimą aplink įrenginį, kad išvengtumėte perkaitimo.
- Saugokite įrenginį nuo vandens, lietaus ar per didelės drėgmės.
- Use appropriate personal protective equipment (PPE) during installation, especially when handling batteries.
- Connect the system only to compatible battery types as specified in this manual.
- Įsitikinkite, kad visi laidai yra tvirtai sujungti ir tinkamai poliarizuoti, kad išvengtumėte elektros pavojų.
- Laikykite vaikus ir neįgaliotus asmenis atokiau nuo sistemos.
3. Pakuotės turinys
Patikrinkite, ar pakuotėje yra visi reikalingi daiktai:
- OLTEANP 2000W Sump Pump Battery Backup System (Main Unit)
- Battery Cables (Red and Black)
- Vartotojo vadovas (šis dokumentas)
- Remote Controller with LCD Screen
- Tvirtinimo priedai (varžtai, inkarai)
- Maitinimo kabelis
- Small Wrench (for terminals)

Figure 3.1: The OLTEANP 2000W Sump Pump Battery Backup System with its remote control, battery cables, power cable, and small wrench.
4. Produktas baigtasview
The OLTEANP 2000W Sump Pump Battery Backup System integrates a pure sine wave inverter, a 25A battery charger, and an automatic transfer switch into one unit. It features multiple output ports and a remote LCD controller for monitoring.
4.1 Priekinio skydelio funkcijos
- 3 kintamosios srovės lizdai: For connecting your sump pump and other AC devices.
- USB Port (5V/3.1A): Skirta mažiems elektroniniams prietaisams įkrauti.
- Type-C Port (30W): Greitesniam suderinamų įrenginių įkrovimui.
- AC Charge Input: Connects to grid power for charging the battery and powering loads.
- Battery Type Selection Switches (DIP Switches): Allows selection of battery chemistry (GEL, AGM/SLA, Flooded/Wet, LiFePO4).
- ĮJUNGIMO/IŠJUNGIMO jungiklis: Pagrindinis keitiklio maitinimo jungiklis.
- Fault LED (Red): Rodo sistemos gedimą.
- Maitinimo šviesos diodas (žalias): Indicates the system is powered on.
- Charge Full LED (Green): Rodo, kad baterija yra visiškai įkrauta.
- Remote Connection Port: For connecting the LCD remote controller.
- Lydusis saugiklis: Apsauga nuo viršsrovių.

Figure 4.1: Front and rear panel connections and indicators.
4.2 Remote Controller with LCD Screen
The remote controller provides real-time monitoring of the system's status, including battery voltage, kintamosios srovės išvesties ttage, power consumption, and fault indicators. This allows for convenient monitoring without direct access to the main unit.

Figure 4.2: The remote controller's LCD screen displaying operational parameters.
5. Sąranka ir diegimas
The OLTEANP Sump Pump Battery Backup System is designed for easy installation with minimal wiring. Follow these steps carefully.
5.1 Įrenginio montavimas
The unit can be placed flat on a stable surface or wall-mounted using the fixed holes on the side. Ensure the mounting location is dry, well-ventilated, and away from flammable materials. Use appropriate screws and anchors for your wall type.
5.2 Akumuliatoriaus prijungimas
- Ensure the main unit is OFF before connecting batteries.
- Prijunkite raudona akumuliatoriaus laidas prie teigiamas (+) terminal of the battery and the teigiamas (+) keitiklio terminalas.
- Prijunkite juodas akumuliatoriaus laidas prie neigiamas (-) terminal of the battery and the neigiamas (-) keitiklio terminalas.
- Tighten all connections securely using the provided wrench.
- Svarbu: The system requires a 12V deep-cycle battery (Lithium, AGM, Flooded/Wet). Do not use non-deep-cycle batteries.
5.3 Baterijos tipo pasirinkimas
Before turning on the inverter, set the DIP switches on the unit to match your battery type. Refer to the table below:

Figure 5.1: DIP switch settings for various battery chemistries.
5.4 Kintamosios srovės įvesties ir išvesties jungtys
- Plug the provided power cable into the AC Charge Input port on the inverter.
- Kitą maitinimo laido galą prijunkite prie standartinio 120 V kintamosios srovės sieninio lizdo.
- Plug your sump pump and other desired AC devices into the 3 AC Outlets on the inverter.
- For permanent installations, the L, N, PE terminals can be used for direct wiring to a breaker panel by a qualified electrician.

Figure 5.2: System diagram showing AC input, battery charging, and inverter output to a sump pump.

Figure 5.3: The 2000W system can power multiple sump pumps with a combined wattage under 2000W.
5.5 Įdiegimo vaizdo įrašas
Video 5.1: Official OLTEANP video demonstrating the Sump Pump Battery Backup System installation and operation.
6. Naudojimo instrukcijos
Once installed, the system operates largely automatically. Here's how to use and monitor it.
6.1 Įjungimas / išjungimas
- To power on the system, press the ON/OFF switch on the main unit. The green Power LED will illuminate.
- Norėdami išjungti maitinimą, dar kartą paspauskite įjungimo/išjungimo jungiklį.
6.2 Automatic Switching (UPS Function)
When grid power is available, the system charges the connected battery and passes AC power directly to your connected devices. In the event of a power outage, the system automatically switches to battery power within 12 milliseconds, ensuring continuous operation of your sump pump. When grid power is restored, it automatically switches back to grid power and resumes charging the battery.
6.3 Monitoring with Remote Controller
The remote LCD controller provides essential information:
- Baterijos lygis: Displays the current charge level of the connected battery.
- DC įėjimas ttage: Rodo baterijos talpątage.
- AC išvesties ttage: Rodo išvesties tūrįtage supplied to your devices.
- Vattage: Rodo dabartinį prijungtų įrenginių energijos suvartojimą.
- Gedimų aliarmai: The screen will flash and display relevant fault codes if an issue occurs.
6.4 Veikimo režimai
- Įkrovimo režimas: When grid power is present, the internal 25A charger replenishes the battery.
- Inverterio režimas: Per galios outage, the system converts DC battery power to AC power for your devices.
Video 6.1: Official OLTEANP video demonstrating the Pure Sine Wave Power Inverter with Charger in operation.
7. Priežiūra
Regular maintenance ensures the longevity and reliable operation of your system.
- Valymas: Periodically clean the exterior of the unit with a dry cloth. Ensure ventilation openings are free from dust and debris.
- Akumuliatoriaus patikrinimas: Regularly check battery terminals for corrosion and ensure connections are tight. For lead-acid batteries, check electrolyte levels if applicable.
- Testavimas: Periodically test the system by temporarily disconnecting grid power to ensure the automatic switching function operates correctly.
- Saugykla: If storing the unit for an extended period, ensure the battery is fully charged and disconnect it from the inverter. Store in a cool, dry place.
8. Problemų sprendimas
Jei kyla problemų, žr. toliau pateiktas dažniausiai pasitaikančias problemas ir sprendimus:
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| No power output from AC outlets. | Unit is off, low battery, overload, fault condition. | Ensure unit is ON. Check battery charge. Reduce load. Check remote controller for fault codes. |
| Akumuliatorius neįkraunamas. | AC input disconnected, incorrect battery type setting, faulty battery. | Verify AC input connection. Check DIP switch settings for battery type. Test battery. |
| Remote controller not displaying. | Loose connection, unit is off. | Ensure remote cable is securely connected. Verify main unit is powered on. |
| Sistema netikėtai išsijungia. | Perkrova, perkaitimas, maža akumuliatoriaus įtampatage, trumpasis jungimas. | Reduce connected load. Ensure adequate ventilation. Recharge battery. Check for short circuits in wiring. |
For persistent issues not covered here, please contact OLTEANP customer support.
9. Specifikacijos
| Funkcija | Detalė |
|---|---|
| Modelio numeris | UPS-TK2000W |
| Vattage | 2000 vatų |
| Įvesties tomastage (DC) | 12 voltų |
| AC išvestis | Pure Sine Wave, 120V AC |
| Akumuliatoriaus įkroviklis | 25A (DC-AC Quick Charge) |
| Medžiaga | Nerūdijantis plienas |
| Prekės svoris | 15.47 svaro |
| Pakuotės matmenys | 20.2 x 12.9 x 6.6 colio |
| Ekrano stilius | LCD (Remote Controller) |
| Įtraukti komponentai | 2000W Sump Pump Battery Backup System, Battery Cables, User Manual, Remote Controller |
| Baterijos įtrauktos | Nr |
| Reikalingos baterijos | Taip |
10. Garantija ir palaikymas
For warranty information and customer support, please refer to the documentation included with your purchase or visit the official OLTEANP websvetainę. Išsaugokite pirkimo čekį garantiniams reikalavimams.