This manual provides essential information for the proper installation, operation, and maintenance of your Ashly TM-360 Public Address Mixer/Amplifier. The TM-360 is a 60-watt, 3-input mixer/amplifier designed for public address applications, featuring transformer-isolated constant-voltage and 4 Ohm outputs. Please read this manual thoroughly before using the product to ensure optimal performance and safety.

Saugos informacija

Always follow basic safety precautions when using electrical products to reduce the risk of fire, electric shock, and injury to persons. This includes, but is not limited to:

  • Prieš pradėdami naudoti prietaisą, perskaitykite visas instrukcijas.
  • Nenaudokite šio prietaiso šalia vandens.
  • Valykite tik sausa šluoste.
  • Neužblokuokite jokių ventiliacijos angų. Montuokite pagal gamintojo instrukcijas.
  • Nemontuokite šalia jokių šilumos šaltinių, pvz., radiatorių, šilumokaičių, viryklių ar kitų įrenginių (įskaitant ampkeltuvai), kurie gamina šilumą.
  • Nepažeiskite poliarizuoto arba įžeminto kištuko saugos tikslo. Poliarizuotas kištukas turi du ašmenis, kurių vienas platesnis už kitą. Įžeminimo tipo kištukas turi dvi mentes ir trečią įžeminimo šakelę. Platus ašmenys arba trečioji šakelė yra jūsų saugumui. Jei pateiktas kištukas netelpa į jūsų elektros lizdą, kreipkitės į elektriką, kad pakeistų pasenusį lizdą.
  • Saugokite maitinimo laidą, kad ant jo neužeitų ar nesuspaustų, ypač prie kištukų, patogių lizdų ir toje vietoje, kur jie išeina iš aparato.
  • Naudokite tik gamintojo nurodytus priedus/priedus.
  • Atjunkite šį įrenginį žaibuojant arba kai nenaudojate ilgą laiką.
  • Visus techninės priežiūros darbus patikėkite kvalifikuotam techninės priežiūros personalui. Techninė priežiūra reikalinga, kai aparatas buvo kaip nors pažeistas, pvz., pažeistas maitinimo laidas arba kištukas, į aparatą išsiliejo skystis ar įkrito daiktai, aparatas buvo paveiktas lietaus ar drėgmės, neveikia normaliai. , arba buvo numestas.

ĮSPĖJIMAS: Kad sumažintumėte gaisro ar elektros smūgio pavojų, nelaikykite šio prietaiso nuo lietaus ar drėgmės.

Produktas baigtasview

The Ashly TM-360 is a versatile public address mixer/amplifier designed for various sound reinforcement needs. Key features include:

  • 3 microphone inputs for versatile audio source connectivity.
  • 60-watt speaker output capable of driving 4 ohm, 8 ohm, 70 volt, or 25 volt speakers.
  • Zone 2 output capable of driving external amplifiers, or a 1-watt 8 ohm speaker.
  • Two-band EQ for master output for tone shaping.
  • Easy-to-use controls located on the front panel for convenient operation.

Sąranka

Galinio skydelio jungtys

The rear panel of the TM-360 provides all necessary connections for power, audio inputs, and speaker outputs. Refer to the image below for a visual guide.

Rear panel of Ashly TM-360 Public Address Mixer/Amplifier showing all connections and controls.

1 paveikslas: Ashly TM-360 Rear Panel Layout. This image displays the AC input, amplifier output terminals, Zone 2 output, mix configuration switches, input gain controls, and various audio input jacks (RCA and terminal blocks).

  • AC INPUT (120V~ 60Hz, 24W): Connect the provided power cord here. Ensure the voltage atitinka jūsų vietinį maitinimo šaltinį.
  • AMPLIFIER OUTPUT 60W: This terminal block provides the main speaker output.
    • COM: Common ground connection.
    • 4Ω: For 4 Ohm speakers.
    • 16V OPT, 25V, 70V, 11Ω, 8Ω: Various constant voltage and low impedance output options. Connect speakers according to their impedance and desired voltage. The "LINK" terminal is for linking multiple units.
  • ZONE 2 OUT: This output provides a secondary audio feed.
    • PRE OUT LOW Z BAL 600Ω: Balanced low impedance pre-output for connecting to external ampgelbėtojai.
    • 1W 8Ω: For connecting a single 1-watt, 8 Ohm speaker directly.
  • INPUT 1 (LINE/MIC): Features a terminal block for balanced line or microphone input. Includes a gain control knob (-10 to +50 dB) and a priority over Input 2 and 3.
  • INPUT 2 (RCA/Terminal Block): Offers both RCA and terminal block connections. Includes a gain control knob (-10 to +10 dB) and priority over Input 3.
  • INPUT 3 (RCA): RCA input connection. Includes a gain control knob (-10 to +10 dB).
  • MANUAL MUTE (CONTACT CLOSURE): Terminal block for external control.
    • 1 & G = INPUT 1 TRIG: Triggers Input 1.
    • G & 2 = MASTER SYSTEM STANDBY: Puts the entire system into standby mode.

Mix Configuration Switch Settings

The TM-360 features a set of DIP switches on the rear panel to configure various mixing and input behaviors. These switches are labeled 1 through 8 under "MIX CONFIGURATION".

Close-up of Ashly TM-360 Mix Configuration DIP switches and settings table.

2 paveikslas: Mix Configuration Switch Settings. This image highlights the DIP switches and their corresponding functions for Zone 2 assignment, VOX trigger, mute, low cut, and phantom power.

Table 1: Mix Configuration Switch Settings
PerjungtiFunkcijaOFF padėtisĮJUNGTA padėtis
1Zone 2 Assign IN 1Input 1 not assigned to Zone 2Input 1 assigned to Zone 2
2Zone 2 Assign IN 2Input 2 not assigned to Zone 2Input 2 assigned to Zone 2
3Zone 2 Assign IN 3Input 3 not assigned to Zone 2Input 3 assigned to Zone 2
4VOX Trig IN 1VOX trigger for Input 1 disabledVOX trigger for Input 1 enabled
5VOX Trig IN 2VOX trigger for Input 2 disabledVOX trigger for Input 2 enabled
6MUTE LINK 2&3Inputs 2 & 3 not linked for muteInputs 2 & 3 linked for mute
7ŽEMAS PJOVIMASLow cut filter disabledLow cut filter enabled
8CH 1 MIC PHANTOMPhantom power for Input 1 disabledPhantom power for Input 1 enabled

Pastaba: Adjust these switches with the unit powered off to prevent unexpected audio behavior.

Naudojimo instrukcijos

Pagrindinė operacija

  1. Maitinimas: Ensure all connections are secure before plugging the unit into an AC outlet. The unit will power on automatically.
  2. Įvesties jungtis: Connect your audio sources (microphones, line-level devices) to the appropriate input jacks (Input 1, 2, or 3) on the rear panel.
  3. Garsiakalbio jungtis: Prijunkite garsiakalbius prie AMPLIFIER OUTPUT terminal block, matching the impedance and voltage settings. For Zone 2, connect either an external amplifier or a 1W 8Ω speaker.
  4. Adjust Input Gain: Use the GAIN knobs for each input to set the appropriate input level. Start with the gain at minimum and slowly increase until the desired level is achieved without distortion.
  5. Adjust Master Output: Use the master volume control (typically on the front panel, though not detailed in the provided image) to set the overall output level.
  6. Adjust Zone 2 Level: Use the ZONE 2 LEVEL knob on the rear panel to control the output level for Zone 2.

Įvesties stiprinimo reguliavimas

Each input (Input 1, Input 2, Input 3) has a dedicated gain control knob on the rear panel. These knobs allow you to match the input sensitivity of the amplifier to the output level of your audio source.

  • 1 įvesties stiprinimas: Adjustable from -10 dB to +50 dB, suitable for both line and microphone levels. Input 1 has priority over Input 2 and Input 3.
  • 2 įvesties stiprinimas: Adjustable from -10 dB to +10 dB. Input 2 has priority over Input 3.
  • 3 įvesties stiprinimas: Adjustable from -10 dB to +10 dB.

To set the gain, start with the knob fully counter-clockwise (minimum gain). Play your audio source at its typical operating level and slowly turn the gain knob clockwise until the signal is clear and strong without clipping or distortion. If a signal is too hot even at minimum gain, consider using an attenuator or a different input.

Zone 2 Level Control

The ZONE 2 LEVEL knob controls the output volume for the Zone 2 output. This allows for independent volume adjustment of the secondary audio zone. Turn the knob clockwise to increase the level and counter-clockwise to decrease it. The range is from OFF to MAX.

Manual Mute Function

The MANUAL MUTE terminal block allows for external control of muting functions via contact closure.

  • 1 & G = INPUT 1 TRIG: Connecting a contact closure between terminal 1 and G will trigger a specific function related to Input 1, typically muting other inputs or activating a priority override.
  • G & 2 = MASTER SYSTEM STANDBY: Connecting a contact closure between terminal G and 2 will put the entire TM-360 system into standby mode, effectively muting all outputs.

Consult specific system design documentation for detailed implementation of these contact closure functions.

Priežiūra

The Ashly TM-360 is designed for reliable operation with minimal maintenance. Follow these guidelines to ensure longevity:

  • Valymas: Disconnect power before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosol sprays.
  • Vėdinimas: Ensure that the ventilation openings on the unit are not blocked. Adequate airflow is crucial for preventing overheating.
  • Kabelių valdymas: Periodically check all cables for wear and tear. Replace damaged cables immediately.
  • Saugykla: Jei įrenginį ketinate laikyti ilgesnį laiką, laikykite jį vėsioje, sausoje vietoje, toliau nuo tiesioginių saulės spindulių ir ekstremalių temperatūrų.

Viduje nėra dalių, kurias galėtų aptarnauti vartotojas. Visus techninės priežiūros darbus patikėkite kvalifikuotiems techninės priežiūros specialistams.

Trikčių šalinimas

If you encounter issues with your TM-360, consult the following common troubleshooting steps:

2 lentelė. Bendras trikčių šalinimo vadovas
ProblemaGalima priežastisSprendimas
Nėra galiosPower cord disconnected; outlet not active; internal fuse blown.Check power cord connection. Test outlet with another device. If fuse is suspected, contact qualified service personnel.
Nėra garso išvestiesInput gain too low; master volume too low; incorrect speaker wiring; input source issue; mute engaged.Increase input gain and master volume. Verify speaker connections and impedance. Check audio source. Ensure Manual Mute is not active.
Iškreiptas garsasInput gain too high; speaker impedance mismatch; faulty cable.Reduce input gain. Verify speaker impedance matches amplifier output. Test with different cables.
Dumbo ar triukšmoĮžeminimo kilpa; sugedęs kabelis; trukdžiai iš kitų elektroninių prietaisų.Ensure all equipment is on the same electrical circuit. Use balanced cables where possible. Isolate the unit from other electronics.
Zone 2 not workingZone 2 level set to OFF; input not assigned to Zone 2; incorrect Zone 2 wiring.Adjust ZONE 2 LEVEL knob. Check DIP switches 1, 2, 3 for correct input assignment to Zone 2. Verify Zone 2 output wiring.

If the problem persists after trying these steps, contact Ashly customer support or a qualified service technician.

Specifikacijos

  • Prekinis ženklas: Ashly
  • Modelis: TM-360
  • Ampstiprintuvo išėjimas: 60 vatų
  • Įėjimų skaičius: 3 (Microphone/Line)
  • Speaker Output Options: 4 Ohm, 8 Ohm, 25 Volt, 70 Volt
  • Zone 2 Output: Pre Out Low Z Balanced 600 Ohm, 1 Watt 8 Ohm
  • Pagrindinis EQ: Two-band
  • Ryšio technologija: Bluetooth
  • Maitinimo šaltinis: Corded Electric (AC INPUT 120V~ 60Hz, 24W)
  • Audio Input Types: Mic, Line (TRS or XLR equivalent via terminal blocks, RCA)
  • UPC: 694970608528

Informacija apie garantiją

The Ashly TM-360 Public Address Mixer/Ampkeltuvas ateina su a 5 metų garantija from the date of purchase. This warranty covers defects in materials and workmanship under normal use. For specific terms, conditions, and to register your product, please refer to the official Ashly websvetainėje arba susisiekite su jų klientų aptarnavimo tarnyba.

Išsaugokite pirkimo įrodymą, kad galėtumėte kreiptis dėl garantijos.

Palaikymas

For further assistance, technical support, or service inquiries regarding your Ashly TM-360, please visit the official Ashly website or contact their customer service department. You can typically find contact information, FAQs, and additional resources on their support pages.

Ashly Audio Inc.
www.ashly.com

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.