This manual provides detailed instructions for the installation, operation, and maintenance of your Garosa Battery Voltage Meter. This device is designed to accurately monitor battery capacity and voltage, featuring a clear LED digital display for various battery types including Lithium and Lead-Acid batteries.
2. Saugos informacija
- Always ensure the power supply is disconnected before installation or maintenance to prevent electrical shock.
- Neviršykite didžiausios įvesties tūriotage iš 120V DC.
- Elkitės su prietaisu atsargiai, kad išvengtumėte fizinės žalos.
- Keep the device away from moisture, extreme temperatures, and corrosive environments.
- Ensure proper wiring connections as indicated in the setup section to prevent damage to the meter or battery.
3. Pakuotės turinys
Į paketą įeina:
- 1 x Garosa Battery Voltage Skaitiklis
4. Produktas baigtasview
The Garosa Battery Voltage Meter is a compact and stable device designed for accurate battery monitoring. It features a high-definition LED screen for clear display of voltage and battery capacity percentage.
Pagrindinės funkcijos:
- High-definition LED Screen: Provides a clear and bright display from all viewkampų.
- Accurate Remaining Capacity: Directly displays battery capacity sign and percentage.
- Battery Capacity Monitor: Tracks battery capacity and voltage.
- Platus suderinamumas: Suitable for various applications including cars, motorcycles, scooters, bikes, power banks, and test equipment.
- Kompaktiškas ir nešiojamas: Designed for ease of use and high measurement accuracy.
Komponento identifikavimas:

4.1 pav.: priekis view of the Garosa Battery Voltage Meter displaying voltage (pvz., 51.3 V).

4.2 pav.: priekis view of the Garosa Battery Voltage Meter displaying battery percentage (pvz., 86%).

4.3 pav.: galinis view of the meter, showing the wiring terminals and battery type selection switches.
5. Sąranka ir diegimas
Follow these steps for proper installation of the battery voltage skaitiklis:
- Montavimas: The meter has a size of approximately 47x27x16mm (1.9x1.1x0.6in) and a mounting hole size of approximately 45.5x26.5mm (1.8x1.0in). Ensure you have an appropriate cutout for flush mounting.
- Laidai:
- Prijunkite raudona viela to the positive (+) terminal of the battery or power source.
- Prijunkite juoda viela to the negative (-) terminal of the battery or power source.
- Ensure connections are secure and insulated to prevent short circuits.
- Baterijos tipo pasirinkimas: Refer to the labels on the back of the meter (Figure 4.3) to select the correct battery type and voltage range using the internal switches. Options typically include 12V, 24V, 48V, 60V, 72V, 96V for Lithium or Lead-Acid batteries. Incorrect selection may lead to inaccurate readings.
- Maitinimas: Once wired correctly, the meter will power on and display the current voltage ir akumuliatoriaus talpa.

5.1 pav. Vidinis view of the meter, showing the circuit board and components. This view is for reference and not for user modification.
6. Naudojimo instrukcijos
The Garosa Battery Voltage Meter operates automatically once connected to a power source within its specified voltage asortimentas.
- Ekrano režimai: The meter typically cycles between displaying the current voltage (V) and the battery capacity percentage (%). Some models may have a button on the side (refer to Figure 6.1) to manually switch between these display modes or to adjust settings.
- Ekrano skaitymas:
- The large digital numbers indicate the voltage arba proctage.
- The battery icon graphically represents the charge level, with green segments indicating remaining capacity and red indicating depleted capacity.
- Stebėjimas: Continuously monitor the display to keep track of your battery's charge status and voltage. This helps in preventing over-discharge or over-charge, extending battery life.

6.1 pav.: šonas view of the meter, potentially showing a button for display mode selection or calibration.
7. Priežiūra
To ensure the longevity and accurate performance of your Garosa Battery Voltage Meter, follow these maintenance guidelines:
- Valymas: Ekraną ir korpusą valykite minkštu, sausu skudurėliu.asing. Nenaudokite abrazyvinių valiklių ar tirpiklių.
- Aplinkos sąlygos: Operate and store the meter within the specified working temperature of -10℃ to +65℃ and avoid high humidity (no condensation).
- Ryšio patikrinimas: Reguliariai tikrinkite laidų jungtis, kad įsitikintumėte, jog jos yra tvirtos ir be korozijos.
- Venkite poveikio: Protect the device from drops or strong impacts.
8. Problemų sprendimas
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| No display or meter does not power on. | Incorrect wiring, no power supply, or voltage outside operating range. |
|
| Netiksli ttage or capacity reading. | Incorrect battery type selection, faulty wiring, or meter malfunction. |
|
| Ekranas blankus arba mirga. | Žemos įvesties tūriotage or unstable power supply. |
|
9. Specifikacijos
| Parametras | Vertė |
|---|---|
| Prekės tipas | Baterijos monitorius |
| Battery Type (Optional) | Lithium Battery, Lead-Acid Battery |
| ttage (neprivaloma) | 12V, 24V, 48V, 60V, 72V, 96V |
| Medžiaga | ABS |
| Spalva | Kaip parodyta paveikslėliuose |
| Dydis | Apytiksliai 47 x 27 x 16 mm / 1.9 x 1.1 x 0.6 col. |
| Montavimo anga | Approx. 45.5x26.5mm / 1.8x1.0in |
| Svoris | apytiksliai 15 g / 0.5 uncijos |
| ttage Matavimo diapazonas | DC 8~120 V (wide range) |
| Maksimalus įvesties tūristage | 120 V |
| Minimum Resolution Below 100 V | 0.1 V |
| Minimum Resolution of 100 V | 1 V |
| Energy Resolution | 1% |
| Darbo srovė | < 15 mA |
| Ekrano ekranas | LED |
| Matavimo rodiklis | > 500 mS / time |
| ttage Matavimo tikslumas | 1% |
| Vielos ilgis | > 150mm / 5.91in |
| Minimali tiekimo apimtistage | + 8 V |
| Didžiausia tiekimo apimtistage | + 120 V |
| Darbinė temperatūra | -10 ℃ ~ +65 ℃ |
| Darbinė drėgmė | (nėra kondensato) |
10. Informacija apie garantiją
Garosa products are manufactured to high-quality standards. This product is covered by a standard limited warranty against defects in materials and workmanship from the date of purchase. Please retain your proof of purchase for warranty claims. The warranty does not cover damage caused by improper installation, misuse, unauthorized modifications, or natural disasters.
11. Parama
For technical assistance, troubleshooting, or warranty inquiries, please contact Garosa customer support through your retailer or the official Garosa website. Please have your product model number (Garosa7q5fcr94ae-15) and purchase details ready when contacting support.