The DX-Smart LR02 is a low-power LoRa module designed for wireless data transmission. It integrates an ASR6601 RF chip and supports UART serial communication, enabling transparent data transfer between devices. This module operates within the 433~475MHz frequency range and is suitable for various Internet of Things (IoT) applications requiring long-range and low-power connectivity.
Pagrindinės funkcijos:
- ASR6601 SOC Chip with 32-bit ARM STAR Core.
- Maximum Frequency: 48MHz.
- UART Serial Communication with configurable baud rates (1200 to 128000).
- Extensive AT command set for module configuration.
- Support for 410~493MHz frequency range, ensuring global compatibility.
- High power PA with +22dBm output.
- Maximum Receiver Sensitivity: -138dBm.
- Supports sleep mode and wake-on-air mode.
- Line-of-sight distance up to 5km in open areas.
- Veikimo ttage: 3.3V-5.5V (typical: 5V).
- Module Size: 36(L)x16.5(W)x4(H)mm.
- CE, FCC, RoHS certified.
2. Setup and Hardware Connection
This section details the physical connection of the LR02 module, including pinout and wiring diagrams. Ensure correct polarity when connecting the module to an adapter board or development environment.
2.1 Module Pinout
The LR02 module features a standard pinout for easy integration. Refer to the diagram below for pin identification and function.

2.1 paveikslas: LR02 Module Pinout and Example Wiring Diagram. The diagram illustrates the pin assignments for the LR02 module and a typical connection to an adapter plate, showing connections for M0, M1, PXD, TXD, RXD, AUX, VCC, and GND.
- M0, M1: Reserved, customizable IO ports.
- PXD: Not explicitly defined in the diagram, but typically related to data transmission.
- TXD: UART Transmit Data.
- RXD: UART Receive Data.
- AUX: Auxiliary pin (refer to detailed documentation for specific functions).
- VCC: Power Supply (3.3V-5.5V).
- BND: Žemė.
2.2 Rodiklio būsena
The module includes an indicator light to show its operational status:
- Darbinė būsena: Red light blinking.
- Hibernacijos režimas: Light off when hibernating, red light flashing when waking up.
3. Operating Modes and AT Commands
The LR02 module supports various working modes and is configured using a comprehensive set of AT commands via its UART serial interface. This allows for flexible integration into different applications without requiring custom LoRa programming.
3.1 Supported Working Modes
The module can operate in three primary data transmission modes:

3.1 paveikslas: Illustration of LR02 Module Working Modes (Transparent, Fixed-Point, Broadcast) and a partial AT Command Set. The diagram visually explains how data is transmitted in each mode and lists common AT commands for configuration.
- Module and Module Transparent Transmission: Requires the same channel for both sender and receiver to transmit data.
- Module and Module Fixed-Point Transmission: Communicates with modules using specified addresses and channels. Data format is hexadecimal: receiving address + receiving channel + data.
- Modules and Module Broadcast Transmission: Communicates with designated channel modules. Data format is hexadecimal: receiver channel + data.
3.2 AT Command Set
AT commands are used to configure and query the module's parameters. A serial port testing software can be used for this purpose.

3.2 paveikslas: Screenshot of a UART Assistant Tools software demonstrating serial port testing and a table of common AT commands. This image shows how to interact with the module using AT commands and a software interface.
Įprastos AT komandos apima:
- AT: Test command (responds with OK).
- +++: Enter/exit AT command mode.
- AT+BAUD: Set/query baud rate.
- AT+MODE: Set/query operating mode.
- AT+SLEEP: Set/query power consumption mode.
- AT+CHANNEL: Set/query working channels.
- AT+MAC: Set/query device address.
- AT+POWE: Set/query transmit power.
- AT+IQ: Setting the IQ signal flip-flop.
For a complete list and detailed usage of AT commands, please consult the product information packages and technical documentation provided by DX-SMART.
4. Priežiūra
The DX-Smart LR02 module is designed for robust operation. To ensure its longevity and reliable performance, consider the following general maintenance guidelines:
- Aplinkos sąlygos: Operate the module within its specified temperature and humidity ranges. Avoid exposure to extreme temperatures, moisture, or corrosive environments.
- Fizinis valdymas: Handle the module with care to prevent physical damage to components or solder joints. Avoid excessive force when connecting or disconnecting antennas and cables.
- Maitinimas: Ensure a stable and clean power supply within the specified voltage range (3.3V-5.5V). Unstable power can affect performance and module lifespan.
- Valymas: If necessary, gently clean the module with a soft, dry cloth. Avoid using liquids or harsh chemicals.
- Firmware atnaujinimai: Periodiškai tikrinkite gamintojo websvetainėje ieškokite visų galimų programinės įrangos atnaujinimų, kurie gali pagerinti našumą arba pridėti naujų funkcijų. Atidžiai laikykitės pateiktų instrukcijų, kad atliktumėte bet kokias atnaujinimo procedūras.
5. Problemų sprendimas
If you encounter issues with your DX-Smart LR02 module, consider the following troubleshooting steps:
- No Power/Indicator Off:
- Patikrinkite maitinimo šaltinio tūrįtage yra 3.3–5.5 V ribose.
- Patikrinkite visus maitinimo laidus, ar jie tinkamai kontaktuoja ir yra poliški.
- Ensure the module is not in hibernation mode (indicator light off).
- Communication Failure (UART):
- Confirm TXD and RXD lines are correctly connected (TX of one device to RX of the other).
- Verify that the baud rate settings on both the module (via AT commands) and the host device match.
- Patikrinkite, ar nėra atsilaisvinusių jungčių ar pažeistų laidų.
- Ensure the module is not in sleep mode, which would prevent communication.
- Poor Wireless Range/Connectivity:
- Ensure the antenna is securely connected and appropriate for the operating frequency.
- Check for obstructions between modules (e.g., thick walls, metal objects).
- Verify that both modules are configured to the same frequency and channel.
- Confirm transmit power settings using AT commands.
- Module Not Responding to AT Commands:
- Ensure you are sending the correct AT command prefix (e.g., '+++' to enter command mode).
- Check serial port settings (baud rate, data bits, parity, stop bits).
- Confirm the module is powered on and not in a deep sleep state.
If problems persist after following these steps, please refer to the technical support section for further assistance.
6. Specifikacijos
Detailed technical specifications for the DX-Smart LR02 LoRa Module:

6.1 paveikslas: Visual representation of the LR02 module highlighting key features and physical dimensions (35.6mm length, 18mm width, 2.54mm pin pitch).
| Parametras | Detalė |
|---|---|
| Chip modelis | ASR6601 |
| Ryšio sąsaja | UART nuoseklusis prievadas |
| Belaidis tipas | Radio Frequency (LoRa) |
| Dažnių juosta | 433~475MHz (Supports 410~493MHz) |
| Perduoti galią | +22dBm |
| Imtuvo jautrumas | -138dBm |
| Bendravimo atstumas | Up to 5km (line-of-sight in open areas) |
| Baudų spartos palaikymas | 1200, 2400, 9600, 19200, 38400, 57600, 115200, 128000 |
| Veiklos ttage | 3.3V-5.5V (Typical: 5V) |
| Darbinė temperatūra | -40°C iki +85°C |
| Modulio matmenys (I x P x A) | 36 mm x 16.5 mm x 4 mm |
| Sertifikatai | CE, FCC, RoHS |

6.2 paveikslas: Image illustrating a drone-measured communication distance test, showing the LR02 module achieving a visible range of up to 5km in an open environment. Note: Actual performance may vary based on environmental factors.
7. Informacija apie garantiją
Specific warranty terms for the DX-Smart LR02 LoRa Module are typically provided at the point of purchase or within the product packaging. For detailed warranty information, including coverage period and conditions, please refer to the documentation supplied by your seller or contact DX-SMART directly.
8. Technical Support and Resources
DX-SMART provides comprehensive technical support and resources to assist with the integration and operation of the LR02 module. These resources include:
- Techninė dokumentacija: Detailed datasheets, user guides, and application notes.
- AT Command Sets: Full documentation of all available AT commands for advanced configuration.
- Module Footprints and Reference Design Schematics: For hardware integration.
- Development/Test Tools: Software and hardware tools to aid in development and testing.
For further assistance or to access these resources, please contact DX-SMART customer service. You can typically find contact information through the 'User Guide', 'Product Information', or 'Service Support' sections on the manufacturer's official websvetainėje arba per savo produkto tiekėją.