Temtop PMD371 & Airing2000 Bundle

„Temtop PMD371“ ir „Airing2000“ profesionalių oro kokybės stebėjimo rinkinių naudotojo vadovas

Model: PMD371 & Airing2000 | Brand: Temtop

1. Įvadas

This user manual provides detailed instructions for the operation and maintenance of the Temtop PMD371 and Airing2000 Professional Air Quality Monitoring Bundle. This bundle offers a comprehensive solution for precise particle and air quality monitoring in various environments, including laboratories, cleanrooms, and field applications. The PMD371 is designed for detailed particle detection and environmental monitoring, while the Airing2000 extends capabilities with advanced particulate and formaldehyde detection. Please read this manual thoroughly before using the devices to ensure proper function and safety.

2. Saugos informacija

  • Nelaikykite prietaisų ekstremalioje temperatūroje, drėgmėje ar tiesioginiuose saulės spinduliuose.
  • Venkite prietaisų numetimo ar stiprių smūgių.
  • Do not attempt to disassemble or modify the devices. Refer all servicing to qualified personnel.
  • Keep the devices away from water and other liquids.
  • Dirbant uždarose patalpose, užtikrinkite tinkamą vėdinimą.
  • Use only the specified power adapters and accessories provided by Temtop.

3. Pakuotės turinys

Patikrinkite, ar pakuotėje yra visi reikalingi daiktai:

  • Temtop PMD371 Particle Counter
  • Temtop Airing2000 Particulate Monitor
  • USB Charging Cables (x2)
  • Maitinimo adapteriai (x2)
  • Vartotojo vadovas (šis dokumentas)
  • Calibration Certificate (if applicable)

4. Produktas baigtasview

Temtop PMD371 and Airing2000 devices side-by-side

Image: The Temtop PMD371 (right) and Airing2000 (left) air quality monitors, showcasing their distinct designs and displays.

Temtop PMD371 Particle Counter front view

Vaizdas: priekis view of the Temtop PMD371 Particle Counter, highlighting its display and control buttons.

Temtop Airing2000 Particulate Monitor front view

Vaizdas: priekis view of the Temtop Airing2000 Particulate Monitor, showing its ergonomic design and display.

4.1 Temtop PMD371 Particle Counter

The PMD371 is a precision instrument designed for multi-size particle detection and environmental monitoring. It features a robust all-metal construction for durability and reliable data collection.

  • Ekranas: Shows real-time particle counts (0.3µm, 0.5µm, 1.0µm, 2.5µm, 5.0µm, 10.0µm), PM2.5, PM10, temperature, and humidity.
  • Maitinimo mygtukas: Įjungia/išjungia įrenginį.
  • Funkciniai mygtukai: Navigation and selection for various modes and settings.
  • Įleidimo anga: Kur orasamples are drawn in for analysis.
  • USB prievadas: Įkrovimui ir duomenų perdavimui.
Temtop PMD371 showing all-metal construction

Image: The Temtop PMD371 highlighting its durable all-metal casing, ensuring robust performance.

Temtop PMD371 dimensions and weight

Image: The Temtop PMD371 illustrating its compact size (170 x 110 x 48 mm) and lightweight design (1.76 lbs), emphasizing its portability.

4.2 Temtop Airing2000 Particulate Monitor

The Airing2000 is designed for comprehensive field monitoring, providing accurate measurements of PM2.5, PM10, TSP, temperature, humidity, and formaldehyde.

  • Ekranas: Shows real-time readings for PM2.5, PM10, TSP, temperature, humidity, and HCHO.
  • Maitinimo mygtukas: Įrenginio įjungimui / išjungimui.
  • Naršymo mygtukai: Meniu naršymui ir nustatymų koregavimui.
  • Oro įleidimo/išleidimo anga: Ports for air sampmolva.
  • Įkrovimo prievadas: Skirta vidinei baterijai įkrauti.
Temtop Airing2000 with features listed

Image: The Temtop Airing2000 showcasing its enterprise-grade precision, industrial-grade pumping sensor, comprehensive monitoring, instant data access, user-friendly operation, and portable design.

Temtop Airing2000 comprehensive monitoring capabilities

Image: The Temtop Airing2000 demonstrating its comprehensive monitoring capabilities, including particulate concentration (PM2.5, PM10, TSP), particle count (0.3µm, 0.5µm, 1.0µm), and environmental conditions (temperature, humidity).

Temtop Airing2000 internal pump-suction sensor

Paveikslėlis: detalus view of the Temtop Airing2000's internal pump-suction sensor, highlighting its advanced optics and wide particle size detection capabilities.

5. Sąranka

5.1 Pradinis įkrovimas

Before first use, fully charge both the PMD371 and Airing2000 devices. Connect the provided USB charging cables to the respective devices and plug them into the power adapters. A full charge typically takes 3-4 hours. The battery indicator on the screen will show charging status.

5.2 Įjungimas / išjungimas

  • Norėdami įjungti: paspauskite ir palaikykite Galia mygtuką, kol ekranas įsijungs.
  • Norėdami išjungti: paspauskite ir palaikykite Galia mygtuką, kol ekranas išsijungs.

5.3 Pagrindiniai nustatymai

Upon first power-on, you may need to set the date, time, and preferred units. Navigate through the menu using the arrow buttons and confirm selections with the OK mygtuką.

  • Data ir laikas: Set current date and time for accurate data logging.
  • Vienetai: Select preferred units for temperature (°C/°F) and particulate matter (µg/m³).

6. Naudojimo instrukcijos

6.1 Taking Measurements with PMD371

  1. Vieta: Position the PMD371 in the area you wish to monitor. Ensure the air inlet is unobstructed.
  2. Pradėti matavimą: Paspauskite START/STOP button to begin continuous monitoring. The screen will display real-time particle counts and environmental data.
  3. Skaitymų vertimas:
    • Particle Counts: Displays the number of particles per liter for various sizes (0.3µm, 0.5µm, 1.0µm, 2.5µm, 5.0µm, 10.0µm).
    • PM2.5/PM10: Shows the concentration of particulate matter in micrograms per cubic meter (µg/m³).
    • Temperatūra/drėgmė: Displays ambient temperature and relative humidity.
  4. Stop Measurement: Paspauskite START/STOP button again to pause or stop monitoring.
  5. Duomenų registravimas: The device automatically logs data. You can access historical data through the menu.
Temtop PMD371 display showing particle count data

Image: The Temtop PMD371's screen displaying detailed particle count data for various sizes (0.3µm, 0.5µm, 0.7µm, 1.0µm, 2.5µm, 5.0µm, 10.0µm) and PM2.5/PM10 concentrations.

6.2 Taking Measurements with Airing2000

  1. Vieta: Hold the Airing2000 or place it in the desired monitoring location. Ensure the air inlet is clear.
  2. Pradėti matavimą: The device typically starts measuring automatically upon power-on. Observe the real-time readings on the display.
  3. Skaitymų vertimas:
    • PM2.5/PM10/TSP: Displays concentrations of various particulate matters.
    • HCHO: Shows formaldehyde concentration.
    • Temperatūra/drėgmė: Displays ambient temperature and relative humidity.
  4. Duomenų valdymas: Use the navigation buttons to review historical data or adjust settings.

6.3 Duomenų perdavimas ir analizė

Both devices support data export. Connect the devices to a computer using the provided USB cables. The devices will appear as a removable storage device, allowing you to access logged data files (e.g., CSV format) for further analysis using spreadsheet software.

7. Priežiūra

7.1 Valymas

  • Wipe the exterior of the devices with a soft, dry cloth.
  • Nenaudokite abrazyvinių valiklių, tirpiklių ar stiprių cheminių medžiagų.
  • Ensure the air inlet and outlet ports are free from dust and debris. Use a soft brush or compressed air if necessary, but avoid forcing anything into the ports.

7.2 Saugykla

  • Store the devices in a cool, dry place, away from direct sunlight and extreme temperatures.
  • If storing for an extended period, ensure the batteries are partially charged (around 50%) to prolong battery life. Recharge every 3-6 months.

7.3 Kalibravimas

The devices are factory calibrated. For professional applications requiring high accuracy, periodic re-calibration by authorized service centers is recommended. Refer to Temtop's official websvetainėje arba susisiekite su klientų aptarnavimo tarnyba dėl kalibravimo paslaugų.

8. Problemų sprendimas

ProblemaGalima priežastisSprendimas
Įrenginys neįsijungia.Žema akumuliatoriaus įkrova; įrenginio gedimas.Visiškai įkraukite įrenginį. Jei problema išlieka, susisiekite su palaikymo tarnyba.
Netikslūs rodmenys.Sensor obstruction; environmental interference; need for calibration.Ensure air inlets are clear. Move away from strong air currents or dust sources. Consider professional calibration.
Ekranas tuščias arba užstrigo.Software error; low battery.Recharge the device. Perform a hard reset (refer to specific device manual for button combination, usually holding power for 10+ seconds).
Nepavyksta prisijungti prie kompiuterio.Faulty USB cable; driver issue; device not in data transfer mode.Try a different USB cable or port. Ensure the device is powered on and in data transfer mode if applicable.

9. Specifikacijos

9.1 Temtop PMD371 Particle Counter

  • Particle Size Channels: 0.3µm, 0.5µm, 1.0µm, 2.5µm, 5.0µm, 10.0µm
  • Measurement Range (PM2.5/PM10): 0–999 µg/m³
  • Temperatūros diapazonas: -10°C iki 50°C (14°F iki 122°F)
  • Drėgmės diapazonas: 0-99 % santykinis drėgnis
  • Baterija: Įkraunamas ličio jonų
  • Matmenys: Apytiksliai 170 x 110 x 48 mm (6.7 x 4.3 x 1.9 colio)
  • Svoris: Apytiksliai 0.8 kg (1.76 svaro)
  • Duomenų saugykla: Up to 5000 sets of data

9.2 Temtop Airing2000 Particulate Monitor

  • Particulate Measurement: PM2.5, PM10, TSP
  • Formaldehyde (HCHO) Range: 0-1.0 mg/m³
  • Temperatūros diapazonas: -10°C iki 50°C (14°F iki 122°F)
  • Drėgmės diapazonas: 0-99 % santykinis drėgnis
  • Baterija: Rechargeable Lithium-ion (Extended battery life)
  • Duomenų saugykla: Ample storage for continuous logging
  • Jutiklio tipas: Industrial-grade pumping sensor

10. Garantija ir palaikymas

10.1 Informacija apie garantiją

Temtop products typically come with a standard manufacturer's warranty covering defects in materials and workmanship. Please refer to the warranty card included with your product or visit the official Temtop webKonkrečias garantijos sąlygas ir nuostatas rasite svetainėje. Išsaugokite pirkimo kvitą kaip pirkimo įrodymą.

10.2 Pagalba klientams

For technical assistance, troubleshooting, or service inquiries, please contact Temtop customer support:

  • Websvetainė: www.temtop.com
  • El. paštas: Žr. kontaktų skiltį oficialioje svetainėje websvetainę.
  • Telefonas: Žr. kontaktų skiltį oficialioje svetainėje websvetainę.

When contacting support, please have your product model number (PMD371 & Airing2000) and purchase date ready.

© 2024 Temtop. Visos teisės saugomos.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.