Vertiv GXE3-1000IRT2UXL

Vertiv Liebert GXE3-1000IRT2UXL UPS User Manual

Model: GXE3-1000IRT2UXL

1. Įvadas

The Vertiv Liebert GXE UPS is an in-line dual conversion single-phase inverter designed to provide robust power protection for critical IT equipment. This system ensures continuous and reliable power, safeguarding connected devices from various AC sector disruptions through its advanced inline double conversion technology. Its flexible design allows for both rack-mount and tower configurations, making it suitable for diverse application environments.

2. Saugos informacija

Prieš įrengdami, naudodami ar atlikdami UPS techninę priežiūrą, perskaitykite ir supraskite visas saugos instrukcijas. Nesilaikant šių instrukcijų, gali kilti elektros smūgis, gaisras arba sunkūs sužalojimai.

  • Elektros sauga: UPS sudėtyje yra pavojingų tūrių.tagNeatidarykite UPS korpuso. Techninę priežiūrą turėtų atlikti tik kvalifikuoti darbuotojai.
  • Įžeminimas: Always connect the UPS to a grounded power outlet. Ensure proper grounding to prevent electric shock.
  • Baterijos sauga: Batteries can present a risk of electrical shock and high short-circuit current. Do not dispose of batteries in a fire. Batteries may explode.
  • Vėdinimas: Ensure adequate airflow around the UPS. Do not block ventilation openings. Maintain a minimum clearance of 20 cm (8 inches) from any obstruction.
  • Aplinka: Operate the UPS in a clean, dry, and temperature-controlled environment. Avoid direct sunlight, excessive heat, humidity, or corrosive contaminants.

3. Produktas baigtasview

3.1 Pagrindinės savybės

  • High Output Power Factor (0.9) for efficient power delivery.
  • High efficiency in online mode (up to 91%) and ECO mode (up to 96%).
  • Compact design, convertible for flexible rack/tower deployment.
  • User-friendly LCD interface for easy monitoring and control.
  • Fast battery recharge time (< 4 hours at 90% for internal batteries).
  • Extended battery life with support for up to 4 optional external battery cabinets (EBC).
  • UPS internal hot-swappable batteries for easy maintenance.
  • Includes Free Vertiv Power Assist software for local UPS status and shutdown.
  • Compatible with Vertiv Power Insight for remote network management.
  • Remote management capability with optional Vertiv Liebert Intellislot IS-UNITY Network Management Cards.

3.2 Vizualinis vadovas

Priekyje view of the Vertiv Liebert GXE3-1000IRT2UXL UPS in tower configuration, showing the LCD display and control buttons.
3.2.1 pav.: priekis View of the UPS. This image displays the front panel of the UPS, highlighting the LCD screen and user interface buttons for status monitoring and configuration.
Galinis view of the Vertiv Liebert GXE3-1000IRT2UXL UPS, showing input power, circuit breaker, and eight IEC C13 output receptacles.
3.2.2 pav.: galinis View of the UPS. This image shows the back panel, detailing the power input, circuit breaker, and eight IEC C13 output ports for connecting protected devices.
Trys ketvirtadaliai view of the Vertiv Liebert GXE3-1000IRT2UXL UPS in tower configuration with base stands.
Figure 3.2.3: UPS in Tower Configuration. This perspective view illustrates the UPS standing upright with its included base stands, suitable for tower deployment.
Šoninė view of the Vertiv Liebert GXE3-1000IRT2UXL UPS in tower configuration, showing the ventilation grilles.
3.2.4 pav.: šonas View of the UPS. This image provides a side profile, highlighting the ventilation grilles essential for proper heat dissipation.

4. Sąranka

4.1 Išpakavimas ir patikrinimas

Carefully unpack the UPS and its accessories. Inspect for any shipping damage. Retain the packaging for future use or return.

4.2 Įdėjimas

Place the UPS in a well-ventilated area, away from direct sunlight, heat sources, and excessive dust or moisture. Ensure sufficient clearance around the unit for proper airflow.

4.3 Configuration (Tower/Rack-Mount)

The GXE3-1000IRT2UXL can be deployed as a tower unit using the included stands or installed in a standard 19-inch rack using an optional rack-mount kit (sold separately). Follow the instructions provided with the rack-mount kit for rack installation.

4.4 Elektros jungtys

  1. Įvesties galia: Connect the UPS input power cord to a grounded electrical outlet. Ensure the outlet provides the correct voltage (230 V) ir srovės talpa.
  2. Išvesties įrenginiai: Connect your critical IT equipment (servers, networking devices, etc.) to the IEC C13 output receptacles on the rear of the UPS. Do not overload the UPS beyond its rated capacity (900W).
  3. Ryšio prievadai: For monitoring and management, connect the appropriate communication cables (USB, RS-232, or optional network card) to your computer or network.

4.5 Pradinis įjungimas

After all connections are secure, press the power button on the front panel to turn on the UPS. The LCD display will illuminate, and the UPS will perform a self-test. Allow the batteries to charge for at least 4 hours before connecting critical loads for optimal runtime.

5. UPS valdymas

5.1 LCD ekranas ir valdymas

The user-friendly LCD display provides real-time status information, including input/output voltage, load level, battery capacity, and operational mode. Use the navigation buttons next to the LCD to scroll through menus and configure settings.

5.2 Darbo režimai

  • Online Mode (Double Conversion): The UPS continuously converts incoming AC power to DC to charge the batteries, and then converts DC back to clean AC power for connected devices. This provides the highest level of power protection.
  • ECO Mode (Economy Mode): In ECO mode, the UPS operates with higher efficiency by bypassing the double conversion process when utility power is stable. It switches to online mode instantly upon detecting power anomalies.

5.3 Programinės įrangos valdymas

For enhanced monitoring and management, install the Vertiv Power Assist software on a connected computer for local control and graceful shutdown. For network-wide management, utilize Vertiv Power Insight or an optional Vertiv Liebert Intellislot IS-UNITY Network Management Card.

6. Priežiūra

6.1 Akumuliatoriaus keitimas

The Vertiv Liebert GXE3-1000IRT2UXL features hot-swappable internal batteries, allowing for replacement without powering down connected equipment. Refer to the detailed battery replacement guide available on the Vertiv support website for specific instructions. Always use genuine Vertiv replacement batteries.

6.2 Valymas

Periodically clean the exterior of the UPS with a soft, dry cloth. Ensure ventilation openings are free from dust and debris to maintain proper airflow and prevent overheating.

6.3 Reguliarūs patikrinimai

Regularly check the UPS status via the LCD display or management software. Verify that input and output connections are secure and that the UPS is operating in the desired mode.

7. Problemų sprendimas

This section provides solutions to common issues you may encounter with your UPS. For more complex problems, contact Vertiv technical support.

ProblemaGalima priežastisSprendimas
UPS neįsijungia.No input power; UPS circuit breaker tripped; Battery deeply discharged.Check power cord connection and wall outlet. Reset the circuit breaker. Allow UPS to charge for several hours.
UPS nuolat pypsi.Overload condition; Low battery.Sumažinkite prijungtą apkrovą. Leiskite baterijoms įsikrauti.
UPS dažnai persijungia į akumuliatoriaus režimą.Nestabilus elektros tiekimas; per didelis jautrumo nustatymas.Check utility power quality. Adjust UPS input sensitivity via LCD or software.

8. Specifikacijos

AtributasVertė
Modelio numerisGXE3-1000IRT2UXL
Talpa (VA/W)1000 900 VA / XNUMX W
Įvesties tomastage230 V
Išėjimo galios koeficientas0.9
Formos faktorius2U Tower / Rack-Mount Convertible
Išvesties talpyklos8 x IEC60320 C13
TechnologijosDual Conversion Online
Efficiency (Online Mode)iki 91 proc.
Efficiency (ECO Mode)iki 96 proc.
Įkrovimo laikas< 4 hours to 90% (internal batteries)
Matmenys (paketas)17.24 x 16.93 x 3.39 colio
Prekės svoris35.2 svaro
ASINB0DX6YTYFZ
UPC767041034967, 767041034394

9. Garantija ir palaikymas

The Vertiv Liebert GXE3-1000IRT2UXL UPS comes with a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official Vertiv websvetainėje, kurioje pateikiamos išsamios garantijos sąlygos.

Techninė pagalba

For technical assistance, troubleshooting, or service inquiries, please contact Vertiv customer support. Contact information and support resources can be found on the official Vertiv websvetainė: www.vertiv.com/en-us/support/

© 2024 Vertiv. All rights reserved. Information subject to change without notice.

Ask a question about this manual