SENSORWORX SWX-121-WH
SENSORWORX SWX-121-WH Light Switch Motion Sensor User Manual
Model: SWX-121-WH | Brand: SENSORWORX
1. Įvadas
This manual provides detailed instructions for the installation, operation, and maintenance of the SENSORWORX SWX-121-WH Light Switch with Motion Sensor. This advanced occupancy sensor utilizes passive dual technology, combining Passive Infrared (PIR) and acoustic detection to ensure efficient and reliable lighting control in various indoor environments. Designed for ease of use and versatility, the SWX-121-WH offers an auto-on (occupancy) switch mechanism and is suitable for 120/277V applications.
2. Saugos informacija
ĮSPĖJIMAS: Risk of electric shock. Improper installation can lead to serious injury or death. Always turn off power at the circuit breaker or fuse box before installing or servicing this device. Installation should be performed by a qualified electrician in accordance with all local and national electrical codes.
- Prieš montuodami atjunkite maitinimą nuo grandinės pertraukiklio.
- Do not use with dimmers or other non-compatible devices.
- Įsitikinkite, kad visos laidų jungtys yra tvirtos ir tinkamai izoliuotos.
- Šis prietaisas skirtas naudoti tik patalpose.
- Darbinės temperatūros diapazonas: nuo 32°F iki 122°F (nuo 0°C iki 50°C).
3. Pakuotės turinys
Prieš pradėdami diegti, patikrinkite, ar yra visi komponentai:
- SWX-121-WH Motion Sensor Light Switch
- Cover Plate (typically sold separately, but implied by "Cover" in components)
- Tvirtinimo varžtai
- Montavimo instrukcijos (šis vadovas)
Note: The product specifications list "Cover, Sensor, Chase Nipple, Lock Nut, Instructions". Assuming "Cover" refers to the faceplate, and "Chase Nipple, Lock Nut" are part of the sensor assembly or mounting hardware. For simplicity, I'll list the main components a user would expect.
4. Produktas baigtasview
The SENSORWORX SWX-121-WH is a sophisticated wall switch occupancy sensor designed for efficient lighting control. It integrates Passive Infrared (PIR) technology to detect body heat and movement, along with acoustic detection to sense sound, ensuring comprehensive occupancy sensing. Its compact design allows for easy installation in standard wall boxes.

4.1 pav.: priekis view of the SENSORWORX SWX-121-WH Light Switch Motion Sensor. This image displays the white faceplate, the upper sensor lens for motion detection, and a lower manual override button. The mounting brackets are visible at the top and bottom.

Figure 4.2: Installation diagram for the SENSORWORX SWX-121-WH. This diagram provides detailed front and side views of the sensor, including dimensions (2.74" height, 1.69" width, 1.39" depth) and labels for components such as the LED indicator, sensor face, button, and break-off bracket ears. The side view emphasizes its shallow design, making it easier to fit into electrical boxes.
Pagrindinės funkcijos:
- Dviguba technologija: Combines Passive Infrared (PIR) and acoustic sensing for enhanced detection accuracy.
- Auto-On (Occupancy) Mode: Automatically turns lights on when occupancy is detected.
- Versatile Wiring: Compatible with installations with or without a neutral wire, and allows for reversed line/load connections.
- Platus ttage Suderinamumas: Supports 120V and 277V AC systems.
- Seklus dizainas: Easier installation in standard wall boxes compared to deeper sensors.
- Bat-Wing Lens: Unique lens design provides enhanced peripheral detection.
5. Montavimas
Before starting, ensure power is OFF at the circuit breaker. This device is designed for single-pole applications.
5.1 Laidų prijungimo instrukcijos
- Išjungti maitinimą: Locate the circuit breaker controlling the light switch and turn it OFF. Verify power is off using a voltage testeris.
- Seno jungiklio pašalinimas: Carefully remove the existing wall plate and unscrew the old switch from the electrical box. Disconnect the wires.
- Identifikuokite laidus:
- Linijos laidas: The incoming hot wire from the circuit breaker.
- Įkrovimo laidas: Laidas eina į šviestuvą.
- Neutralus laidas (neprivaloma): If present, typically white. The SWX-121-WH can operate with or without a neutral connection.
- Žemės viela: Plikas varis arba žalias laidas.
- Prijunkite laidus:
- Prijunkite Linija wire to the sensor's designated Line terminal.
- Prijunkite Įkelti wire to the sensor's designated Load terminal.
- Jeigu a Neutralus wire is present, connect it to the sensor's Neutral terminal. If no neutral is available, the sensor will operate in a no-neutral configuration.
- Prijunkite Žemė wire from the electrical box to the sensor's ground screw.
Note: The SWX-121-WH allows for reversal of line and load connections for installation flexibility. Refer to the wiring diagram provided with the product for specific terminal identification.
- Saugūs ryšiai: Ensure all wire connections are tight and secure using wire nuts or screw terminals as appropriate.
5.2 Jutiklio montavimas
- Padėties jutiklis: Gently push the wired sensor into the electrical box, ensuring wires are not pinched.
- Secure Sensor: Use the supplied mounting screws to secure the sensor to the electrical box. The break-off bracket ears can be removed if needed for multi-gang installations.
- Įdiekite sieninę plokštę: Attach the decorative wall plate (not included with sensor, but required for finish) over the sensor.
- Atkurti maitinimą: Įjunkite maitinimą grandinės pertraukikliu.
6. Sąranka ir konfigūracija
Upon initial power-up, the sensor will enter a warm-up period. During this time, the LED indicator may flash. Once stable, the sensor is ready for configuration.
6.1 Nustatymų reguliavimas
The SWX-121-WH typically has default settings for sensitivity and time delay. Advanced settings may be accessible via specific button press sequences or external configuration tools (if applicable, not specified in product description). For basic operation, the sensor will automatically turn lights on when occupancy is detected and off after a set time delay when the space is vacant.
- Laiko delsa: This setting determines how long the lights remain on after the last detected occupancy. Common settings range from 30 seconds to 30 minutes.
- Jautrumas: Adjusts the responsiveness of the PIR and acoustic sensors. Higher sensitivity detects minor movements and sounds, while lower sensitivity requires more significant activity.
- Perėjimo režimas: Some sensors offer a short time delay for brief occupancy, like walking through a hallway.
Consult the detailed programming guide or manufacturer's website for specific instructions on adjusting these parameters for your model.
7. Operacija
The SENSORWORX SWX-121-WH operates primarily in an auto-on (occupancy) mode, providing hands-free lighting control.
7.1 Automatinis veikimas
- When a person enters the detection zone, the PIR sensor detects motion, and the acoustic sensor detects sound.
- Upon detection, the lights will automatically turn ON.
- As long as occupancy is maintained (through continued motion or sound), the lights will remain ON.
- After the space becomes vacant for the set time delay, the lights will automatically turn OFF.
7.2 Rankinis nepaisymas
The SWX-121-WH typically includes a manual override button on the faceplate. Pressing this button allows you to:
- Turn lights ON manually if they are OFF (overriding occupancy).
- Turn lights OFF manually if they are ON (overriding occupancy).
Note: Manual override behavior may vary. Some models revert to automatic operation after a period, while others maintain the manual state until another manual press or power cycle.
8. Priežiūra
The SENSORWORX SWX-121-WH is designed for minimal maintenance. Regular cleaning can help ensure optimal performance.
- Valymas: Periodically wipe the sensor lens and faceplate with a soft, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals, as these can damage the surface or sensor components.
- Kliūtys: Ensure that there are no obstructions (e.g., furniture, curtains, tall plants) blocking the sensor's field of view, as this can impair detection.
- Dulkių kaupimasis: Excessive dust on the sensor lens can reduce sensitivity. Clean as needed.
Always turn off power at the circuit breaker before cleaning or performing any maintenance that requires touching the sensor directly.
9. Problemų sprendimas
If you experience issues with your SENSORWORX SWX-121-WH, refer to the following table for common problems and solutions.
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| Lights do not turn ON automatically. |
|
|
| Lights turn OFF too quickly or unexpectedly. |
|
|
| Lights remain ON constantly. |
|
|
| LED indikatorius neveikia. |
|
|
10. Specifikacijos
| Funkcija | Detalė |
|---|---|
| Modelio numeris | SWX-121-WH |
| Prekės ženklas | SENSORWORX |
| Technologijos | Passive Infrared (PIR) & Acoustic |
| ttage | 120 / 277V kintamosios srovės |
| Dažnis | 50/60Hz |
| Load Rating (120VAC) | 800W |
| Load Rating (277VAC) | 1200W |
| Jungiklio konfigūracija | 1-Pole, Auto-On (Occupancy) |
| Aptikimo diapazonas | Up to 48 Feet (PIR) |
| Matmenys (A x P x G) | 2.74" x 1.68" x 1.39" |
| Spalva | Baltas |
| Darbinė temperatūra | nuo 32 °F iki 122 °F (nuo 0 °C iki 50 °C) |
| Montavimo tipas | Surface Mount (Standard Wall Box) |
| Maitinimo šaltinis | Su laidu elektra |
| Prekės svoris | 3.84 uncijos (0.24 svaro) |
| Pagaminta | JAV |
11. Garantija ir palaikymas
11.1 Informacija apie garantiją
The SENSORWORX SWX-121-WH Light Switch with Motion Sensor is backed by a 5 metų garantija from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, misuse, abuse, or unauthorized modifications.
Išsaugokite pirkimo įrodymą, kad galėtumėte kreiptis dėl garantijos.
11.2 Pagalba klientams
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact SENSORWORX customer support:
- Websvetainė: www.sensorworx.com
- El. paštas: support@sensorworx.com
- Telefonas: Please refer to the SENSORWORX websvetainė, kurioje pateikiami dabartiniai kontaktiniai numeriai.
When contacting support, please have your product model number (SWX-121-WH) and date of purchase readily available.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.