The MEXYBE 4-in-1 Digital Water Tester is designed to accurately measure Total Dissolved Solids (TDS), Electrical Conductivity (EC), and temperature in both Celsius and Fahrenheit. This device features a high-precision chip and a premium titanium alloy probe for reliable results. It is suitable for testing drinking water, RO/DI systems, aquariums, hydroponics, pools, and more.

Pagrindinės funkcijos:

  • 4 viename funkcionalumas: Measures TDS, EC, Temperature (°C, °F).
  • Didelis, foniniu apšvietimu veikiantis LCD ekranas: 25% larger display for easy reading.
  • Automatinio užrakinimo funkcija: Simplifies usage by locking readings.
  • Gamykloje kalibruota: Ready for direct use.
  • Laikymo funkcija: Freezes the reading on the display.
  • Automatinis išjungimas: Išsijungia po 2 minučių neveiklumo, kad taupytų bateriją.
  • TDS Chart: Convenient chart on the back of the tester and in the user guide for quick PPM value interpretation.
MEXYBE 4-in-1 TDS Meter showing 4 display modes: TDS, EC, Celsius, Fahrenheit.

Image 1.1: The MEXYBE 4-in-1 TDS Meter displaying its four measurement modes: TDS (ppm), EC (µs/cm), Celsius (°C), and Fahrenheit (°F). Note that the device does not measure pH or water hardness.

2. Sąranka ir komponentai

Before first use, ensure the batteries are correctly installed. The device comes with 2 LR44 batteries included and pre-installed.

2.1 Komponentai

Diagram of MEXYBE 4-in-1 TDS Meter components including battery compartment, LCD, buttons, probe, and pen cup.

Image 2.1: Detailed diagram of the MEXYBE 4-in-1 TDS Meter, highlighting its key components: two replaceable batteries, energy-efficient chipset, large backlit LCD, MODE button, CLEAR button, ON/OFF HOLD button, immerse line, highly sensitive titanium alloy probe and sensor, and pen cup.

  1. Baterijų skyrius: Located at the top, holds two LR44 batteries.
  2. Apšviestas LCD ekranas: Rodo matavimo rodmenis.
  3. MODE mygtukas: Switches between TDS, EC, and Temperature (°C/°F) display modes.
  4. CLEAR mygtukas: Clears the current reading.
  5. ON/OFF HOLD Button: Powers the device on/off and activates the hold function.
  6. Immerse Line: Indicates the maximum immersion depth for the probe.
  7. Titanium Alloy Probe: High-precision sensor for accurate measurements.
  8. Pen Cup: Protective cover for the probe.

2.2 Akumuliatoriaus įdėjimas

The device comes with batteries pre-installed. To replace batteries:

  1. Gently slide open the battery compartment cover at the top of the device.
  2. Remove the old LR44 batteries.
  3. Insert two new LR44 batteries, ensuring correct polarity.
  4. Saugiai uždarykite akumuliatoriaus skyriaus dangtelį.

3. Naudojimo instrukcijos

Follow these steps for accurate water quality testing:

  1. Paruoškite SampLe: Pour the water to be tested into a clean container.
  2. Maitinimas: Paspauskite ON/OFF HOLD button to turn on the meter. The display will light up.
  3. Immerse the Probe: Remove the protective pen cup. Dip the probe into the water sample up to the immerse line. Do not immerse above this line.
  4. Hand immersing the TDS meter probe into a glass of water up to the immerse line.

    Image 3.1: Proper immersion of the TDS meter probe into a water sample. Ensure the water level does not exceed the indicated immerse line.

  5. Stir Gently: Gently stir the meter in the water to remove any air bubbles and ensure a stable reading.
  6. Hand gently stirring the TDS meter in a glass of water.

    Image 3.2: Gently stirring the meter in the water to ensure accurate and stable readings by removing air bubbles.

  7. Laukite skaitymo: Allow a few seconds for the reading to stabilize. The auto-lock function will typically hold the stable reading.
  8. TDS meter displaying a stable reading after a short wait.

    Image 3.3: The TDS meter displaying a stable reading after the probe has been immersed and gently stirred in the water sample.

  9. Read the Value: Read the displayed value. If the reading is not locked, press the ON/OFF HOLD button to freeze the display.
  10. Hand pressing the ON/OFF HOLD button on the TDS meter to lock the reading.

    Image 3.4: Pressing the ON/OFF HOLD button to manually freeze the displayed reading for easier recording.

  11. Perjungti režimus: Paspauskite REŽIMAS button to cycle through TDS (ppm), EC (µs/cm), Celsius (°C), and Fahrenheit (°F) measurements.
  12. Išjungti: Paspauskite ON/OFF HOLD button again to turn off the meter. The device will automatically shut off after 2 minutes of inactivity.
  13. Valyti ir laikyti: Rinse the probe with clean water and replace the protective pen cup before storing.

3.1 Interpreting TDS Readings

A colorful TDS chart is provided on the back of the tester and in this guide for quick reference:

TDS chart showing water quality levels based on PPM values.

Image 3.5: TDS chart illustrating water quality based on PPM (parts per million) values. Ranges include Ideal drinking water (0-50 ppm), Comparatively ideal drinking water (50-100 ppm), High hardness water (100-200 ppm), Marginally Acceptable (200-300 ppm), Scale will form (300-400 ppm), The taste is not very pleasant (400-500 ppm), and U.S EPA's maximum contamination level (500+ ppm).

TDS Measurement Guidelines (PPM)
PPM diapazonas Vandens kokybė
0-50 Ideal drinking water
50-100 Comparatively ideal drinking water
100-200 High hardness water
200-300 Iš dalies priimtina
300-400 Scale will form
400-500 The taste is not very pleasant
>500 U.S EPA's maximum contamination level

4. Priežiūra

Proper maintenance ensures the longevity and accuracy of your MEXYBE TDS Meter.

  • Zondo valymas: After each use, rinse the probe thoroughly with clean distilled water to prevent residue buildup. Do not use abrasive materials or harsh chemicals.
  • Saugykla: Always replace the protective pen cup after use. Store the meter in a cool, dry place away from direct sunlight and extreme temperatures.
  • Baterijos keitimas: Replace batteries when the display becomes dim or the meter fails to power on. Use only LR44 batteries.
  • Kalibravimas: The meter is factory calibrated. If you suspect inaccurate readings over time, recalibration may be necessary. Refer to the manufacturer's website or contact support for detailed calibration instructions.

5. Problemų sprendimas

If you encounter issues with your TDS meter, refer to the following common problems and solutions:

Problema Galima priežastis Sprendimas
Matuoklis neįsijungia. Neišsikrovusios arba neteisingai įdėtos baterijos. Patikrinkite baterijų poliškumą arba pakeiskite jas naujomis LR44 baterijomis.
Netikslūs arba nestabilūs rodmenys.
  • Probe not clean.
  • Air bubbles on the probe.
  • Water temperature outside operating range.
  • Meter requires recalibration.
  • Rinse probe thoroughly with distilled water.
  • Gently stir the meter in the sample to remove bubbles.
  • Ensure water temperature is within 0-80°C (32-176°F).
  • Contact customer support for recalibration guidance.
Ekranas blankus. Maža akumuliatoriaus energija. Replace batteries with new LR44 batteries.

6. Specifikacijos

Funkcija Detalė
Modelio numeris A2
Išmatavimai TDS (Total Dissolved Solids), EC (Electrical Conductivity), Temperature (°C, °F)
TDS diapazonas 0–9999 ppm
Temperatūros diapazonas 0–80 °C (32–176 °F)
Tikslumas ±2 %
Baterijos 2 x LR44 (pridedama)
Automatinis išjungimas 2 minučių
Prekės svoris 1.76 uncijos
Pakuotės matmenys 6.38 x 1.3 x 0.71 colio

7. Garantija ir palaikymas

MEXYBE is committed to providing high-quality products and excellent customer service. Your satisfaction is our priority.

  • Klientų aptarnavimas: For any questions, concerns, or technical assistance, please contact our dedicated customer support team. We offer rapid and efficient responses through live chat and email.
  • Atsiliepimai: We value our customers' feedback to continuously improve our products and services.

For further assistance, please refer to the contact information provided with your product packaging or visit the official MEXYBE websvetainę.

© 2025 MEXYBE. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.