GoodTop AFGW-SWTG218ANS

GoodTop 2.5Gb Web Valdomas PoE jungiklis

Model: AFGW-SWTG218ANS

1. Įvadas

This manual is prepared for installers and system administrators responsible for network installation, configuration, and maintenance. It assumes the user has a foundational understanding of network communication, management protocols, technical terms, and practical skills related to networking devices and protocols.

2. Saugos informacija

Please read and understand all safety instructions before operating the device. Improper operations can lead to data loss or equipment damage. Always ensure proper grounding and use the provided power supply. Avoid exposing the device to extreme temperatures or humidity.

3. Pakuotės turinys

Patikrinkite, ar pakuotėje yra visi reikalingi daiktai:

  • 1 x GoodTop 2.5Gb Web Valdomas PoE jungiklis
  • 1 x maitinimo laidas
  • 1 x User Manual (PDF available at Vartotojo vadovas PDF)
  • 1 x Certification
Packing List and Specifications
Detailed specifications including packing list.

4. Produktas baigtasview

The GoodTop 2.5Gb Web Managed PoE Switch is designed for high-speed network environments, offering advanced management features and Power over Ethernet capabilities.

GoodTop 2.5G Web Valdomas PoE jungiklis
Priekyje view of the GoodTop 2.5G Web Managed PoE Switch, highlighting 100W PoE Power, 8x 2.5G POE, 1x 10G SFP+ Slots, Web Managed Functions, LACP/VLAN.

4.1 Prievado įvadas

The switch features 8x 2.5G PoE ports and 1x 10G SFP+ optical port. Each port has indicator lights for status and speed.

Port Introduction Diagram
Diagram illustrating the Reset Button, PWR/SYS indicators, 8*100/1000/2500M POE Ports, 1*10G SFP+ Optical Port, Grounding Screw, and AC 100-240V Power Supply.
  • Atkūrimo mygtukas: Naudojamas įrenginiui iš naujo nustatyti.
  • PWR: Maitinimo indikatorius.
  • SYS: System indicator light.
  • 8*100/1000/2500M POE Port: Ethernet ports supporting 100Mbps, 1Gbps, and 2.5Gbps speeds with PoE capabilities. Yellow indicator light: 10/100/1000M. Green indicator light: 2.5G.
  • 1*10G SFP+ Optical Port: High-speed fiber optic port. Blue indicator light: 10G. Green indicator light: 1G/2.5G.
  • Įžeminimo varžtas: Dėl tinkamo elektros įžeminimo.
  • Maitinimas: AC 100-240V input.

4.2 Pagrindinės savybės

  • Upgrade to 2.5G/10G Network: Supports high-speed data transmission.
  • Web Management: Intuitive web-based interface for configuration.
  • Multiple Management Functions: Includes LACP, PoE, QoS, VLAN Support, IGMP Snooping, Spanning Tree, Port Isolation, Bandwidth Control, Jumbo Frame, MAC Constraint, EEE, Storm Control.
  • High Speed PoE Chips: Efficient power delivery for connected devices.
  • Efficient Heat Dissipation: Metal casing with ventilation holes for optimal performance.
  • 100W PoE Power Budget: Provides ample power for multiple PoE devices.
  • Compatible with 2.5G Devices: Ideal for PCs, Laptops, WiFi 6 Routers, 2.5G NAS, WiFi 6 APs, and Firewalls.
Upgrade to 2.5G/10G Network
Visual representation of 2.5Gbps RJ45 ports for network upgrade.
Compatible 2.5G Network Devices
Illustrates various 2.5G network devices compatible with the switch, such as PC/Laptop, WiFi 6 Router, 2.5G NAS, WiFi 6 AP, and Firewalls.

5. Sąranka

5.1 Pradinis prisijungimas

Connect your computer to any of the switch's Ethernet ports using a standard Ethernet cable. Ensure the switch is powered on.

5.2 Web Puslapio prisijungimas

Norėdami pasiekti web valdymo sąsaja:

  1. Atidarykite a web browser (Chrome 23.0+, Firefox 20.0+, or superior to IE 9.0 is recommended).
  2. Type the default switch IP address: http://192.168.2.1 į adreso juostą ir paspauskite Enter.
  3. A login window will appear. Enter the default username admin ir slaptažodį admin.
  4. Click "Log in" to access the switch system.

Pastaba: For the first login, ensure your PC's IP address is in the same network segment as the switch (e.g., 192.168.2.x, where 1 < x ≤ 254) and the subnet mask is 255.255.255.0.

Web Management Login Interface
Ekrano kopija web management login interface with default credentials.

6. Naudojimo instrukcijos

The web management interface provides various menu items for configuring and monitoring the switch.

6.1 Sistemos nustatymai

The System menu allows you to view device information, configure IP settings, manage user accounts, and adjust port settings.

  • Informacija: Displays device model, MAC address, IP address, firmware version, etc.
  • IP nustatymas: Change the management IP address, netmask, and gateway.
  • Vartotojo paskyra: Modify the username and password for web prieiga.
  • Prievado nustatymas: Configure individual Ethernet port parameters like state (enable/disable), speed/duplex, and flow control.

6.2 POE Configuration

The POE menu allows you to configure and monitor Power over Ethernet ports.

  • PoE Port configuration: Enable/disable PoE power for individual ports.
  • PoE Port status: View the current status and power consumption of PoE ports.
PoE Total Power 100W
Illustration of the switch's 100W PoE total power capability.

6.3 Tinklo konfigūracija

The Configuration menu provides advanced network settings.

  • VLAN: Configure Virtual Local Area Networks, including 802.1Q VLAN and 802.1Q VID.
  • QoS (paslaugų kokybė): Set processing priorities for different data frame tags, including Port to Queue and Queue Weight.
  • Ciklas: Configure loop detection/prevention and Spanning Tree Protocol (STP) settings.
  • IGMP šnipinėjimas: Manage multicast groups to optimize network traffic.
  • Trunk Group Setting: Configure Link Aggregation (static or LACP) to increase bandwidth and reliability.
  • Port-based Mirroring: Copy traffic from a source port to a destination port for monitoring.
  • Uosto izoliacija: Isolate ports to prevent direct communication between them.
  • Pralaidumo valdymas: Restrict data transmission and reception rates on physical interfaces.
  • Jumbo rėmas: Set the Maximum Transmission Unit (MTU) for ports.
  • MAC Constraint: Limit MAC address learning on ports.
  • EEE (Energy Efficient Ethernet): Configure energy-saving features.
Multiple Management Functions
Diagram illustrating the range of management functions available on the switch.

6.4 Saugos nustatymai

The Security menu allows you to manage MAC addresses and control storm traffic.

  • MAC adresas: View and manage the MAC address forwarding table, including MAC search and static MAC entries.
  • Audros valdymas: Prevent broadcast, unknown multicast, and unicast storms by suppressing excessive packet rates.

7. Priežiūra

The Tools menu provides utilities for system maintenance.

  • Programinės įrangos atnaujinimas: Update the switch firmware. Do not power off during the upgrade process.
  • Konfigūracijos atsarginė kopija: Save the current switch configuration.
  • Atstatyti: Restore factory settings and reboot the system.
  • Išsaugoti: Save the current configuration changes.
  • Perkraukite: Iš naujo paleiskite jungiklį.
  • Atsijungti: Išeikite iš web valdymo sistema.

8. Problemų sprendimas

Jei kyla problemų, žr. šiuos įprastus sprendimus:

  • Negaliu prieiti web sąsaja: Ensure your PC's IP address is in the same subnet as the switch (default 192.168.2.x) and that the switch is powered on. Try clearing your browser cache.
  • Network performance issues: Check port statistics under the Monitoring menu. Verify bandwidth control settings and ensure no loops are present (refer to Loop settings).
  • PoE devices not powering on: Verify PoE port configuration and ensure the total PoE power budget (100W) is not exceeded. Check cable integrity.
  • VLAN Tagging: This switch supports VLAN tags. Access ports can be configured as tagged arba untagged. Trunk ports typically operate as hybrid types, supporting both. Ensure your VLAN configurations match your network requirements.

9. Specifikacijos

Detailed product specifications for the GoodTop AFGW-SWTG218ANS switch:

AtributasVertė
Produkto pavadinimas9 Port 10G Uplink 2.5G Managed POE Switch
Uosto apibrėžimas8*100/1000/2500M POE Port + 1*10G SFP+ Optical Port
Tiekimas ttageĮvesties tomastage: AC 100-240V, 50/60Hz; Supply Power: DC 52V 2.88A
Backplane Bandwidth60 Gbps
Paketų persiuntimo greitis44.64 Mpps
MAC adresų lentelė4K
Package Cache8 Mbit
Tinklo protokolaiIEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3ab, IEEE802.3x, IEEE802.3bz
„PoE“ standartasIEEE802.3af (15.4 W), IEEE802.3at (30 W)
PoE Port Output VoltageDC 44-57V
PoE Whole Power100W
Darbinė temperatūra0-40°C
Laikymo temperatūra-10-70°C
Darbinė drėgmė10% ~ 90%, Nekondensuojantis
Sandėliavimas Drėgmė5% ~ 95%, Nekondensuojantis
Produktas NW0.91 kg
Produktas GW1.23 kg
Produkto dydis (L × P × A)220 mm × 161 mm × 44 mm
Pakuotės dydis (I × P × A)315 mm × 215 mm × 85 mm
SertifikavimasCE, FCC, RoHS
Gaminio parametrų lentelė
Visual representation of product parameters including dimensions and performance metrics.

10. Vartotojo patarimai

  • VLAN konfigūracija: When setting up VLANs, remember that both tagged ir untagged configurations are supported on access ports. Trunk ports are designed to handle both, offering flexibility for various network designs.
  • Pradiniai nustatymai: Always ensure your computer's IP address is temporarily set within the 192.168.2.x range for the first login to the web valdymo sąsaja.
  • Firmware atnaujinimai: Regularly check for and apply firmware updates to ensure optimal performance and security. Always follow the instructions carefully and do not interrupt the process.

11. Garantija ir palaikymas

GoodTop provides a 1-year warranty for this product. Lifetime professional technical support is also available to assist with any queries or issues you may encounter.

Susiję dokumentai - AFGW-SWTG218ANS

Preview GoodTop GT-ST024M Smart-Web Perjungti Web vadovas
Tai web manual provides detailed instructions and configuration guidance for the GoodTop GT-ST024M Smart-Web Switch, covering system information, port management, VLANs, QoS, advanced features, and system administration.
Preview SODOLA SL-AFGW-242S-400 išmanusisWeb Perjungti Web vadovas
Tai web Vadove pateikiama išsami „SODOLA SL-AFGW-242S-400 Smart“ konfigūravimo ir valdymo informacija.Web Jungiklis. Tai apima sistemos informaciją, IP nustatymus, vartotojų paskyras, prievadų konfigūraciją, PoE nustatymus, VLAN, QoS, kilpų prevenciją, IGMP šnipinėjimą, SNMP, jungčių agregavimą, prievadų veidrodinį atspindėjimą, prievadų izoliavimą, pralaidumo valdymą, didelius rėmelius, MAC apribojimus, EEE, saugos funkcijas, tokias kaip MAC adresų valdymas ir „Storm Control“, stebėjimo įrankius ir sistemos įrankius, tokius kaip programinės įrangos atnaujinimas, atsarginių kopijų kūrimas, atstatymas, išsaugojimas ir perkrovimas.