Hantek DSO2C10/2C15/2D10/2D15

Hantek Digital Storage Oscilloscope User Manual

Models: DSO2C10, DSO2C15, DSO2D10, DSO2D15

1. Įvadas

This manual provides detailed instructions for the Hantek DSO2C10, DSO2C15, DSO2D10, and DSO2D15 Digital Storage Oscilloscopes. These devices are designed for precise measurement and analysis of electronic signals, offering advanced features for various applications in electrical engineering and DIY projects. Please read this manual thoroughly before operating the device to ensure safe and efficient use.

2. Pagrindinės savybės

  • 2 channels, each controlled by independent knobs.
  • 100 MHz or 150 MHz analog channel bandwidth.
  • 1 GSa/s realiu laiku sample norma.
  • 8M memory depth.
  • Vertical range: 2mV/div ~ 10V/div.
  • Built-in 1 CH 5MHz waveform generator (DSO2D10 and DSO2D15 models only).
  • Vertical resolution: 8-bit.
  • Multiple trigger types: Edge, Pulse width, Video, Slope, Overtime, Window, Pattern, Interval, Delay, UART, LIN, CAN, SPI, IIC.
  • CAN decode and protocol analysis: RS232/UART, I2C, SPI, CAN, LIN.
  • Ability to save data in multiple formats: setting, waveform, reference waveform, CSV, picture.
  • 5-bit digital voltage meter and 6-bit hardware frequency indicator function.
  • 32 kinds of auto measurements with statistics, including real-time statistics of maximum, minimum, standard deviation, etc.
  • 2 sets of digital voltmeter.
  • Support for threshold testing and free measurements within the screen.
  • Abundant SCPI remote command control.
  • Multiple external interfaces: USB Host/Device.

Note: DSO2C10 and DSO2C15 models do not include the waveform generator function.

3. Specifikacijos

3.1 General Device Information

  • Prekinis ženklas: Hantekas
  • Modelių numeriai: DSO2C10, DSO2C15, DSO2D10, DSO2D15
  • Sertifikavimas: CE
  • Kilmė: Žemyninė Kinija
  • DIY Supplies Category: Elektros
  • Skaitmeniniai kanalai: 2
  • Ekrano skiriamoji geba: 800*480 pikselių
  • Ekrano dydis: 7 colių ir daugiau
  • Įtraukta baterija: Nr
  • IS Battery Demountable: Nr
  • Didelį susirūpinimą kelianti cheminė medžiaga: Nėra
  • Max Waveform Capture Rate: 50 000 WFM/s
  • Įrašo ilgis: 8M
  • Realiu laiku S.amplingo kaina: 1GSa/S

3.2 Veikimo specifikacijos

ParametrasDSO2D15DSO2D10DSO2C15DSO2C10
Pralaidumas150 MHz100 MHz150 MHz100 MHz
Rising time in BNC position (typical)2.3ns3.5ns2.3ns3.5ns
Vertikali skiriamoji geba8 bits resolution, each channel samples simultaneously
Vertikalus jautrumas2mV/div to 10V/div
Poslinkio diapazonas2mV/div to 20mV/div, ±100mV; 50mV/div to 200mV/div, ±1V; 500mV/div to 2V/div, ±10V; 5V/div to 10V/div, ±50V
Matematinis veiksmas+, -, ×, ÷, FFT
FFTWindow: Rectangle, Hanning, Hamming, Blackman, Bartlett, Flattop
Pralaidumo riba20 MHz
Bass response(-3db)In BNC position ≤ 10Hz
Vertical gain accuracyIn "normal" or "average" acquisition mode, the accuracy of 10V/div to 10mV/div is ±3%; In "normal" or "average" acquisition mode, the accuracy of 5mV/div to 2mV/div is ±4%
DC offset accuracy±0.1 div±2 mV±1% offset value
ttage measurement repeatability, average acquisition modeUnder the same setting and environment, ≥16 waveforms are sampled, △V of any two averages: ±(3%×value+ 0.05 div)
Note: Bandwidth reduced to 6MHz when using a 1X probe

For a visual representation of these specifications, refer to the image below:

Table of general oscilloscope specifications including bandwidth, rising time, vertical resolution, and trigger types.
Figure 3.1: Performance Specifications Table

3.3 Trigger Specifications

ParametrasAprašymas
Trigerio tipasEdge, Pulse width, Video, Slope, Overtime, Window, Pattern, Interval, Delay, UART, LIN, CAN, SPI, IIC
Trigerio lygio diapazonas±5 divisions from the center of the screen
Trigerio režimasAuto, general, single
LygisCH1-CH2±4 divisions from the center of the screen
EXT0~3.3V
Holdoff range8ns ~ 10s
Trigerio lygio tikslumasCH1-CH20.2 div×volts/div within ±4 divisions from the center of the screen
EXT±(Set value× 6%+40mV)
Krašto gaidukasŠlaitasRising edge, falling edge, rising or falling edge
Signalo šaltinisCH1, CH2, EXT
Impulso pločio trigerisPoliškumasPositive polarity, negative polarity
Condition (When)<, >, !=, =
Signalo šaltinisCH1-CH2
Impulsų pločio diapazonas8 ns ~ 10 s
Tikslumas8ns
Vaizdo įrašo aktyviklisSignalo standartasNTSC, PAL
Signalo šaltinisCH1-CH2
SinchronizavimasScanning line, line number, odd field, even field, all field
Nuolydžio gaidukasŠlaitasrise, fall
Condition (When)<, >, !=, =
Signalo šaltinisCH1 ~ CH2
Laiko intervalas8 ns ~ 10 s
Tikslumas8ns
Overtime triggerSignalo šaltinisCH1-CH2
PoliškumasPositive polarity, negative polarity
Laiko intervalas8 ns ~ 10 s
Tikslumas8ns

For a visual representation of these trigger specifications, refer to the image below:

Table of detailed trigger specifications including trigger types, levels, and ranges.
Figure 3.2: Trigger Specifications Table

3.4 Modelių palyginimas

ModelisKanalasPralaidumasSample normaAtminties gylisAFG
DSO2C102 CH100 MHz1GSa/S8MBe
DSO2C152 CH150 MHz1GSa/S8MBe
DSO2D102 CH+1CH100 MHz1GSa/S8M1 CH
DSO2D152 CH+1CH150 MHz1GSa/S8M1 CH

For a visual comparison of the models, refer to the image below:

Table comparing Hantek oscilloscope models DSO2C10, DSO2C15, DSO2D10, DSO2D15 by channel, bandwidth, sample rate, memory depth, and AFG.
3.3 pav.: Modelių palyginimo lentelė

4. Pakuotės turinys

The package contents vary slightly depending on the specific model (C-series vs. D-series). Please check your package against the relevant list below.

4.1 DSO2C10 / DSO2C15 Package

  • Hantek Digital Storage Oscilloscope (DSO2C10 or DSO2C15 model)
  • Maitinimo laidas
  • USB kabelis
  • Oscilloscope Probes (quantity may vary)
  • User Manual / Certification
Package contents for Hantek DSO2C10 and DSO2C15 oscilloscopes, showing the device, power cord, USB cable, probes, and manual.
Figure 4.1: DSO2C10 / DSO2C15 Package Contents

4.2 DSO2D10 / DSO2D15 Package

  • Hantek Digital Storage Oscilloscope (DSO2D10 or DSO2D15 model)
  • Maitinimo laidas
  • USB kabelis
  • Oscilloscope Probes (quantity may vary)
  • BNC to Alligator Clip Cables (for waveform generator output)
  • User Manual / Certification
Package contents for Hantek DSO2D10 and DSO2D15 oscilloscopes, showing the device, power cord, USB cable, probes, BNC to alligator clip cables, and manual.
Figure 4.2: DSO2D10 / DSO2D15 Package Contents

5. Sąranka

  1. Išpakavimas: Carefully remove the oscilloscope and all accessories from the packaging. Inspect for any signs of damage.
  2. Maitinimo jungtis: Connect the provided power cord to the power input on the rear panel of the oscilloscope and then to a suitable AC power outlet.
    Galinis view of the Hantek DSO2D15 oscilloscope showing the power input and USB port. A warning label indicates hazardous voltage and advises against removing the cover.
    5.1 pav.: Galinio skydelio jungtys

    ĮSPĖJIMAS: Pavojingas ttage inside. Do not remove the cover unless by specified personnel.

  3. Zondo jungtis: Connect the oscilloscope probes to the CH1 and CH2 BNC inputs on the front panel. Ensure a secure connection.
  4. Įžeminimas: Always connect the probe's ground clip to the circuit's ground point to ensure accurate measurements and safety.
  5. Maitinimas: Press the power button to turn on the oscilloscope.
Priekyje view of the Hantek DSO2D15 oscilloscope displaying a waveform and control panel.
5.2 pav.: Priekinis skydelisview

6. Naudojimo instrukcijos

This section covers the basic operation and key functions of your Hantek Digital Storage Oscilloscope.

6.1 Pagrindinės operacijos

  1. Automatinis nustatymas: For a quick setup, press the AUTOMATINIS NUSTATYMAS button. The oscilloscope will automatically adjust the vertical, horizontal, and trigger settings to display a stable waveform.
  2. Vertikalūs valdikliai: Naudokite VOLTS/DIV knobs for CH1 and CH2 to adjust the vertical scale (voltage per division). Use the POZICIJA knobs to shift the waveform vertically.
  3. Horizontalūs valdikliai: Naudokite SEC/DIV knob to adjust the horizontal scale (time per division). Use the POZICIJA knob to shift the waveform horizontally.
  4. Trigerio sistema: Trigerių sistema stabilizuoja pasikartojančias bangų formas ir fiksuoja vienkartinius įvykius.
    • Trigerio lygis: Sureguliuokite TRIGGER LEVEL rankenėlę garsumui nustatytitage level at which the trigger occurs.
    • Aktyviklio režimas: Select between Auto, Normal, and Single trigger modes using the menu options.
    • Trigerio tipas: Access the trigger menu to select various trigger types such as Edge, Pulse Width, Video, Slope, etc.
Priekyje view of the Hantek DSO2D15 oscilloscope showing a waveform with various measurement parameters displayed on screen.
Figure 6.1: Oscilloscope Display with Measurements

6.2 Išplėstinės funkcijos

  • Išmatavimai: The oscilloscope supports 32 types of automatic measurements. Access the measurement menu to select and display parameters like Vpp, Vmax, Vmin, Freq, Period, etc.
  • Waveform Generator (DSO2D10/DSO2D15 only): Use the built-in 1 CH 5MHz waveform generator to output various test signals. Connect the output to your circuit under test.
  • Protocol Analysis: Utilize the decoding and protocol analysis features for RS232/UART, I2C, SPI, CAN, and LIN signals. Refer to the on-screen menu for specific setup and analysis options.
  • Duomenų išsaugojimas: Waveforms, settings, and screenshots can be saved to a USB drive connected to the USB Host port. Use the SAVE/RECALL menu for these operations.

Watch the product overview video for a demonstration of key features and operation:

Video 6.1: Hantek Oscilloscope Product Overview

7. Priežiūra

  • Valymas: Regularly clean the exterior of the oscilloscope with a soft, damp šluoste. Nenaudokite abrazyvinių valiklių ar tirpiklių. Prieš valydami įsitikinkite, kad įrenginys išjungtas ir atjungtas nuo elektros tinklo.
  • Saugykla: Store the oscilloscope in a dry, dust-free environment away from direct sunlight and extreme temperatures.
  • Zondų priežiūra: Handle probes carefully. Avoid bending or stressing the probe tips. Calibrate probes periodically as per the on-screen utility menu.
  • Vėdinimas: Ensure the ventilation openings on the device are not blocked to prevent overheating.

8. Problemų sprendimas

Jei kyla problemų dėl osciloskopo, žr. šias dažniausiai pasitaikančias problemas ir sprendimus:

  • Nerodoma bangos forma:
    • Check probe connections to the oscilloscope and the circuit.
    • Ensure the input signal is within the oscilloscope's voltage asortimentas.
    • Paspauskite AUTOMATINIS NUSTATYMAS mygtuką.
    • Sureguliuokite VOLTS/DIV ir SEC/DIV nustatymus.
    • Verify the trigger level is set correctly and the trigger mode is appropriate for the signal.
  • Nestabili bangos forma:
    • Sureguliuokite TRIGGER LEVEL.
    • Ensure the trigger source is correctly selected.
    • Check for noise in the signal or poor grounding.
  • Įrenginys neįsijungia:
    • Verify the power cord is securely connected to both the oscilloscope and the power outlet.
    • Patikrinkite, ar maitinimo lizdas veikia.

Dėl sudėtingesnių problemų kreipkitės į klientų aptarnavimo tarnybą.

9. Vartotojo patarimai

  • Always perform a probe compensation adjustment when using new probes or if measurements seem inaccurate. This can usually be found in the Utility menu.
  • When measuring high-frequency signals, use the shortest possible ground lead on your probe to minimize inductance and ringing.
  • Familiarize yourself with the various trigger types. Using the correct trigger can significantly simplify capturing complex or intermittent signals.
  • Utilize the internal memory or a USB drive to save important waveforms for later analysis or documentation.

10. Garantija ir palaikymas

All delivered products are tested before shipping to ensure full functionality. We offer after-sales service within 1 year of purchase. In case of missing or defective parts, please notify us no later than 5 days after receiving the item for arrangement of re-shipment.

For technical support or warranty claims, please contact your retailer or the manufacturer directly. Please have your model number and purchase date available when contacting support.