Fujitsu S26113-E567-V50-02 DPS-500XB A

Fujitsu S26113-E567-V50-02 DPS-500XB A Server Power Supply User Manual

Model: S26113-E567-V50-02 DPS-500XB A

Įvadas

This manual provides essential information for the proper installation, operation, and maintenance of the Fujitsu S26113-E567-V50-02 DPS-500XB A Server Power Supply. This unit is designed to provide stable and reliable power to compatible server systems. Please read this manual thoroughly before installation and use.

Fujitsu DPS-500XB A Server Power Supply front view
Priekyje view of the Fujitsu DPS-500XB A Server Power Supply, showing the main power connector.

Specifikacijos

The following table details the technical specifications of the Fujitsu S26113-E567-V50-02 DPS-500XB A Power Supply:

Product label with detailed electrical specifications for Fujitsu DPS-500XB A power supply
Detailed product label showing model, input, and output specifications.
Funkcija Detalė
Modelio numeris S26113-E567-V50-02, DPS-500XB A
Gamintojas Fujitsu Technology Solutions
Maksimali išėjimo galia 500W
AC įvestis 100-240V~, 7-3.5A, 50-60Hz
DC Output +12V1 17A (18A 20SEC)
DC Output +12V2 17A (18A 20SEC)
DC Output +12V3 15A (18A 20SEC)
DC Output +12V4 15A (18A 20SEC)
DC Output +12V5 17A (18A 20SEC)
DC Output +12V6 0.5A (1A 20SEC)
AUX DC Output +12V 1A
AUX DC Output +5V 2A
Nuolatinės srovės išvestis +11 V 2A (2.5A 1SEC)
Ventiliatoriai 1
PFC tipas Aktyvus
CPU maitinimo jungtis 4 kaištis
Taikymas Darbalaukis
Modulinis Ne modulinis
80 PLUS sertifikatas Auksas
Kilmė Žemyninė Kinija
Būklė Second hand, Tested working 100%

Sąranka ir diegimas

Proper installation is crucial for the safe and efficient operation of your power supply. Always ensure the server system is powered off and disconnected from the main power source before beginning installation.

  1. Pirmiausia sauga: Disconnect all power cables from the server and ensure no residual power remains. Wear an anti-static wrist strap to prevent electrostatic discharge (ESD) damage to components.
  2. Išimkite seną maitinimo šaltinį (jei taikoma): Carefully disconnect all cables from the existing power supply unit (PSU). Unscrew and remove the old PSU from the server chassis.
  3. Įdiekite naują maitinimo šaltinį: Gently slide the Fujitsu DPS-500XB A power supply into the designated PSU bay in your server chassis. Ensure it is seated correctly and align the screw holes.
  4. Saugus maitinimo šaltinis: Use the appropriate screws to firmly secure the power supply to the server chassis.
  5. Prijunkite maitinimo laidus:
    • Connect the main ATX power connector to the motherboard.
    • Connect the 4-pin CPU power connector to the motherboard.
    • Connect any necessary peripheral power cables (SATA, Molex, PCIe, etc.) to your drives, expansion cards, and other components. Ensure all connections are firm and correctly oriented.
  6. Kabelių valdymas: Route cables neatly to improve airflow and prevent interference with other components.
  7. Galutinis patikrinimas: Double-check all connections to ensure they are secure and correctly installed.
  8. Maitinimas: Connect the server's power cord to the PSU and then to a grounded electrical outlet. Power on the server.
Šoninė view of the power supply showing the AC input port and ventilation grill
Šoninė view of the power supply, highlighting the AC input and cooling fan area.

Naudojimo instrukcijos

Once installed, the power supply operates automatically to deliver power to your server components. No specific user interaction is typically required during normal operation.

  • Maitinimo įjungimas/išjungimas: The power supply is controlled by the server's power button and operating system. Ensure the server is properly shut down before disconnecting power.
  • Vėdinimas: Ensure the server chassis has adequate ventilation to allow proper airflow for the power supply's cooling fan. Blocked vents can lead to overheating and component failure.
  • Stabilus maitinimo šaltinis: Connect the server to a stable and grounded power outlet. Using a surge protector or Uninterruptible Power Supply (UPS) is recommended to protect against power fluctuations.
Galinis view of the power supply showing the fan and cable exit point
Galinis view of the power supply, showing the cooling fan.

Priežiūra

Regular, simple maintenance can extend the lifespan of your power supply and ensure optimal performance.

  • Dulkių šalinimas: Periodically clean dust from the power supply's fan and ventilation grilles using compressed air. Ensure the server is powered off and unplugged before cleaning.
  • Patikrinkite kabelius: Occasionally check power cables for any signs of wear, fraying, or damage. Replace damaged cables immediately.
  • Aplinkos sąlygos: Operate the server in a clean, dry, and well-ventilated environment within recommended temperature ranges to prevent overheating.

Trikčių šalinimas

Jei kyla problemų dėl maitinimo šaltinio, vadovaukitės toliau pateiktais įprastais trikčių šalinimo veiksmais.

  • Nėra galios:
    • Ensure the power cord is securely plugged into both the PSU and the wall outlet.
    • Patikrinkite, ar sieninis lizdas veikia, prijungdami prie jo kitą įrenginį.
    • Check all internal power connections (motherboard, CPU, peripherals) are firmly seated.
  • Sistemos nestabilumas / atsitiktiniai išsijungimai:
    • This could indicate an overloaded or failing PSU. Ensure your system's power requirements do not exceed the PSU's 500W capacity.
    • Check for overheating. Ensure proper ventilation and clean any dust from the PSU fan.
  • Garsus ventiliatoriaus triukšmas:
    • Excessive fan noise can be caused by dust accumulation. Clean the fan blades and grille.
    • If the noise persists, the fan bearing might be failing, which could require professional service or replacement.
  • Degimo kvapas:
    • Immediately power off and unplug the server. Do not attempt to use it. This indicates a serious electrical fault and requires professional inspection.

Naudotojo patarimai

  • Given this is a second-hand unit, it's advisable to perform a thorough visual inspection for any physical damage or signs of wear before installation.
  • Always ensure compatibility with your server's motherboard and chassis form factor before attempting installation.
  • When replacing a power supply, take note of the original cable routing to simplify the installation of the new unit.

Garantija ir palaikymas

This product comes with a 3-month warranty period, effective from the date the package is delivered. The warranty covers manufacturing defects and operational failures under normal use.

  • Garantijos išimtys: The warranty is void if the product is damaged due to improper use, unauthorized modifications, or physical abuse.
  • Techninė pagalba: For technical assistance or warranty claims, please contact your vendor or the original manufacturer, Fujitsu Technology Solutions.
  • Grąžinimo ir pinigų grąžinimo politika: For details regarding returns and refunds, please refer to the specific policy provided by your seller at the time of purchase.

„Fujitsu“ serverio maitinimo šaltinis S26113-E567-V50-02 DPS-500XB A 500W „Visual Over“view

„Fujitsu“ serverio maitinimo šaltinis S26113-E567-V50-02 DPS-500XB A 500W „Visual Over“view

0:20 • 540 × 1176 • vizualinis_perdengimasview

Susiję dokumentai - S26113-E567-V50-02 DPS-500XB A

Preview Fujitsu PRIMERGY TX1330 M3 Server System Configurator and Order Guide
This document provides detailed system configuration and order information for the Fujitsu PRIMERGY TX1330 M3 Tower or 4U Rack server. It covers various components, options, and specifications to help users build and order their desired server configuration.
Preview FUJITSU PRIMERGY TX1310 M1 Server: Operating Manual and User Guide
Official operating manual for the FUJITSU PRIMERGY TX1310 M1 server. Get detailed guidance on installation, setup, operation, safety, specifications, and troubleshooting for this Intel-based server designed for workgroups and small networks.
Preview Fujitsu PRIMERGY TX1320 M4 Tower Server Configuration and Order Guide
Comprehensive guide detailing the configuration options, components, specifications, and order codes for the Fujitsu PRIMERGY TX1320 M4 small form factor tower server.
Preview „Fujitsu PRIMERGY RX2540 M5“ sistemos konfigūratoriaus ir užsakymo informacijos vadovas
Išsamus „Fujitsu PRIMERGY RX2540 M5 2U Rack“ serverio konfigūravimo ir užsakymo vadovas. Šiame dokumente išsamiai aprašomi sistemos komponentai, parinktys ir specifikacijos, padėsiančios sukurti pritaikytą serverio sprendimą.
Preview „Fujitsu PRIMERGY RX2530 M8“ serverio konfigūravimo ir užsakymo vadovas
Explore the Fujitsu PRIMERGY RX2530 M8 1U Rack Server with this comprehensive configurator and order information guide. Discover base units, drive cages, CPU, RAM, graphics, storage, networking, power supply options, and more for optimal system building.
Preview „Fujitsu PRIMERGY RX1330 M4 Rack“ serveris: sistemos konfigūratoriaus ir užsakymo informacijos vadovas
Išsamus vadovas, kuriame išsamiai aprašomos „Fujitsu PRIMERGY RX1330 M4“ stovo serverio konfigūravimo parinktys, specifikacijos ir užsakymo informacija. Apima pagrindinius įrenginius, procesorius, atmintį, saugyklą, tinklus, maitinimo šaltinius ir kitus komponentus.