SINOTIMER STVP936-1-80A

User Manual: Three-Phase Adjustable Over/Under Voltage gynėjas

Model: STVP936-1-80A

1. Įvadas

The SINOTIMER STVP series automatic over-voltage ir pagal ttage protector is designed for three-phase 3*127V/220VAC power systems with a rated working current of 80A. This device provides essential protection for electrical equipment by instantaneously cutting off the power supply when over-voltage, pagal ttage, or over-current conditions are detected. Once the circuit voltage returns to normal, the protector automatically restores power, ensuring continuous operation and safeguarding your appliances from damage.

This protector integrates multiple protection functions including over-voltage, pagal ttage, over-current, three-phase current (voltage) imbalance, phase sequence (reverse phase), zero-break, and phase-break protection. It also features voltmeter and ammeter functions, and the ability to restore factory settings. The device offers comprehensive features, stable performance, and ease of operation.

Išsamų naudotojo vadovą PDF formatu galima atsisiųsti: Vartotojo vadovas (PDF)

2. Pagrindinės savybės

  • Per tomastage apsauga
  • Nepakankamas tomastage apsauga
  • Apsauga nuo viršsrovių
  • Automatinis atkūrimas
  • ttage display (separate ABC phase voltage matavimas)
  • Ampere display (separate ABC phase ampere measurement)
  • Trifazis ampere unbalance protection
  • Phase sequence protection (reverse phase protection)
  • Zero line break protection
  • Fazių gedimų apsauga
  • Fault inquiry function
  • Rotation display of voltage and current for each phase
  • Adjustable over-voltage protection value and recovery value
  • Adjustable under-voltage protection value and recovery value
  • Adjustable over-current protection value and action time
  • Adjustable 3-phase ampere unbalance protection value and action time
  • Adjustable delay time after power-on
  • Adjustable fault recovery delay time
  • Factory data reset function

3. Gaminio specifikacijos

AtributasVertė
Modelio numerisSTVP936-1-80A
Maitinimo šaltinis3*127V/220VAC 60Hz
Įvertintas ttage220 V
FazėTrijų fazių
Maks. Apkrovos srovė1~80A Adjustable (default: 80A)
Per tomastage Apsaugos diapazonas121V-150V-OFF Adjustable (default: 140V)
Per tomastage Recovery Range120V-149V (default: 135V)
Per tomastage Action Time0.1~10 seconds (default: 0.2s)
Nepakankamas tomastage Apsaugos diapazonas118V-80V-OFF Adjustable (default: 90V)
Nepakankamas tomastage Recovery Range118V-91V (default: 95V)
Nepakankamas tomastage Action Time0.1~10 seconds (default: 0.2s)
3-Phase Volt Unbalance Protection10%~50%~OFF (default: 20%)
3-Phase Volt Unbalance Action Time0.1~10 seconds (default: 1s)
Delay Time After Power-on2~255 seconds (default: 2s)
Fault Recovery Delay Time2~600 seconds (default: 60s)
Ekrano modelisLCD
Matmenys71.5mm (W) * 95.2mm (H) * 65.7mm (D)
Montavimas35 mm DIN bėgis
SertifikavimasCE, RoHS

4. Saugos informacija

  • Montavimą ir techninę priežiūrą turėtų atlikti tik kvalifikuoti elektrikai.
  • Prieš bet kokius montavimo ar laidų darbus įsitikinkite, kad maitinimo šaltinis yra atjungtas.
  • The device does not provide overload or short-circuit protection. It must be used in conjunction with appropriate external circuit breakers (e.g., C45, C65 mini circuit breakers) for comprehensive protection.
  • Prieš įjungdami maitinimą, patikrinkite, ar visos laidų jungtys yra tvirtos ir teisingos.
  • Do not operate the device in wet or hazardous environments.

5. Montavimas

5.1 Fiziniai matmenys

Dimensions of the STVP936-1-80A protector, showing width 71.5mm, height 95.2mm, and depth 65.7mm.
1 pav.: Gaminio matmenys

5.2 Montavimas

The protector is designed for 35mm DIN rail installation. Snap the device onto the DIN rail securely.

Šoninė view of the protector showing its compatibility with a DIN rail for mounting.
Figure 2: DIN Rail Mounting

5.3 Sujungimo schema

Connect the input and output terminals as shown in the diagram below. Ensure correct phase (L1, L2, L3) and neutral (N) connections. The input terminals are located at the top, and output terminals at the bottom.

Priekyje view of the protector with input (N, L1, L2, L3) and output (N, L1, L2, L3) terminals clearly labeled with arrows.
Figure 3: Input/Output Terminal Labels
Detailed wiring diagram showing connections from a power switch to the voltage protector (IN terminals) and from the voltage protector (OUT terminals) to an air circuit breaker.
4 pav.: Bendroji laidų schema

6. Sąranka ir konfigūracija

Norėdami įjungti nustatymo režimą, paspauskite ir palaikykite NUSTATYTI button for 3 seconds. Then, continuously press NUSTATYTI to cycle through the parameters. Use the ir buttons to adjust the values. When "ENd" appears, press NUSTATYTI again to save the data and exit the setting mode.

If no operation is performed within 10 seconds after pressing NUSTATYTI, the device will automatically exit the setting mode, and any unsaved changes will be lost.

6.1 Parameter Settings Table

ŽingsnisTurinysLCD ekranasDescription / Range (Default)
1Per tomastage apsaugos vertėUvo 280V221V-300V-OFF (280V)
2Per tomastage atkūrimo vertėUvor 250V220 V–299 V (250 V)
3Per tomastage apsaugos veikimo laikas0.2 m0.1–10 s (0.2 s)
4Nepakankamas tomastage apsaugos vertėUve 160V219V-150V-OFF (160V)
5Nepakankamas tomastage atkūrimo vertėUver 180V151 V–220 V (180 V)
6Nepakankamas tomastage apsaugos veikimo laikas0.2 m0.1–10 s (0.2 s)
7Apsaugos nuo viršsrovės vertė>In 80A1-80A (80A)
8Over-current protection action time5S1–512 s (5 s)
93 fazės amp unbalance protection value>In %5%-90%-OFF (25%). Not active if current < 2A.
103 fazės amp unbalance protection action time1.0 S0.1–10 s (1 s)
11Fazių sekos apsaugaON ABCON or OFF (ON)
12Įjungimo delsos laikas2 S2–255 s (2 s)
13Fault recovery delay time60 S2–512 s (60 s)
14Fault inquiry codeE0Press ▲ to view last 5 fault records (E1-E5). >U for overvoltage, <U for undervoltage.
15PabaigaGalasPress SET to save and exit.

6.2 Gamyklinių parametrų atkūrimas

To reset the device to factory settings, press and hold the ir mygtukus vienu metu 3 sekundes.

7. Operacija

Once installed and configured, the device will continuously monitor the three-phase power supply. The LCD screen will automatically rotate to display the real-time voltage and current for each phase (L1, L2, L3).

Esant per dideliam tūriuitage, pagal ttage, or over-current event, the protector will automatically trip and cut off the power supply to protect connected equipment. After the fault condition clears and the recovery delay time has passed, the device will automatically restore power.

8. Problemų sprendimas

8.1 Fault Inquiry

If a fault occurs, the device will display an error code (E0). You can press the button to query the last 5 fault records (E1-E5). The display will indicate:

  • ">U" for overvoltage renginiai.
  • "<U" for undervoltage renginiai.

8.2 Phase Sequence Error

If the LCD displays "ABC" character, it indicates a phase sequence error. To correct this, arbitrarily reverse any two of the three phase lines (L1, L2, L3) at the input.

9. Priežiūra

  • Laikykite prietaisą švarų, be dulkių ir drėgmės.
  • Regularly check wiring connections for tightness and signs of wear or damage.
  • Do not attempt to repair the device yourself. Refer to qualified personnel for service.

10. Garantija ir palaikymas

For technical support, inquiries, or warranty claims, please contact the distributor:

Platintojas: XNY INTERNATIONAL LIMITED

Adresas: Room 20A, Kiu Fu Commercial Building, 300 Lockhart Road, Wanchai, Hong Kong.

Tel: 0086 57761733853

Faksas: 0086 577 89736991

WhatsApp: 0086 1565857 3377

Wechat: sinotimer

Skype: sinotimer

Web: www.sinotimer.com

El. paštas: info@sinotimer.com

Susiję dokumentai - STVP936-1-80A

Preview SINOTIMER SVP719 naudotojo vadovas: tomastage Apsauga, energijos skaitiklis ir energijos suvartojimo monitorius
Išsamus SINOTIMER SVP719 naudotojo vadovas, kuriame išsamiai aprašomos jo funkcijos, pvz., reguliuojamas virš/po garso lygio reguliatoriustage apsauga, viršįtampių apsauga, viršsrovės ribojimo relė ir vatų/kWh energijos skaitiklis energijos suvartojimui stebėti.
Preview SVP-916 išmanusis viršgarsio reguliatoriustage Ribinės srovės apsaugos naudojimo instrukcija
SINOTIMER SVP-916 išmaniojo viršįtampio jutiklio naudojimo instrukcijatage, pagal ttage ir viršsrovės apsauga vienfazėms 230 V kintamosios srovės sistemoms. Išsamios elektros įrangos apsaugos savybės, parametrai ir nustatymo metodai.
Preview SINOTIMER WiFi Smart Switch Instruction Manual
Comprehensive instruction manual for the SINOTIMER WiFi Smart Switch, detailing network setup via the Graffiti Smart APP, device unbinding and reset procedures, indicator light status, electricity consumption display, and configuration of overvoltage, nesuprantamatage, and overcurrent protection settings.
Preview SINOTIMER DTS6619 3 Phase Energy Meter | 100A DIN Rail kWh Monitor
Detaliau baigtaview of the SINOTIMER DTS6619 3 Phase Energy Meter. Features 100A capacity, DIN rail mounting, LCD display, high accuracy, and MODBUS-RTU RS485 interface for monitoring kWh, voltage, srovė ir galia.
Preview Sinotimer TM610-2 Digital Timer User Manual and Operation Guide
Comprehensive guide to operating the Sinotimer TM610-2 digital timer, covering its three independent working modes (Prog, Pulse, Countdown), setting real-time, programming schedules, and battery replacement. This manual provides detailed instructions for users to effectively utilize the timer's features for automated control.
Preview „Sinotimer MT-S PID“ temperatūros reguliatorius: funkcijos, specifikacijos ir sąrankos vadovas
Išsami informacija apie „Sinotimer MT-S“ išmaniąją PID temperatūros valdymo relę, įskaitant funkcijas, technines specifikacijas, laidų schemas ir PID bei įjungimo-išjungimo valdymo režimų nustatymo instrukcijas.