1. Įvadas

The UNI-T UT693A series is a versatile 4-in-1 fiber optic tester designed for comprehensive network and fiber optic cable analysis. It integrates an optical power meter, a visual fault locator (VFL) with a red light source, a network cable detector, and an LED flashlight. This compact and portable device is ideal for technicians and engineers requiring accurate measurements and efficient troubleshooting in various fiber optic and network environments.

Pagrindinės funkcijos:

  • Optical Power Measurement with 10 wavelengths and two measurement ranges.
  • Visual Fault Locator (VFL) with 1mW or 30mW red light source for identifying fiber breaks, bends, and dirty connectors.
  • Network Cable Testing for wire order and signal checks.
  • Built-in LED Flashlight for working in dark environments.
  • Auto Calibration (Self-Adjust) for accurate loss/gain measurements.
  • Data Logging capability to store up to 500 power readings.
  • Patogumui C tipo USB įkrovimas.

2. Pakuotės turinys

Patikrinkite pakuotę, ar joje yra šie daiktai:

  • Main Unit (UT693A series Optical Multimeter)
  • Spalvų dėžutė
  • C tipo įkrovimo laidas
  • Vartotojo vadovas (šis dokumentas)
  • Sertifikatas ir garantijos kortelė
Image showing the UNI-T UT693A device, its packaging, Type-C cable, and a small user manual.
Figure 2.1: Product Family Photo - What's in the Box

3. Produktas baigtasview

Familiarize yourself with the components of your UT693A device:

Diagram of the UNI-T UT693A-T30 showing labeled parts: Optical Power Meter Interface, LED Flashlight, Type-C Charging Port, Network Cable Test Port, Cable Test Module, Red Light Source Port, Display, Keypad.
Figure 3.1: UT693A Component Diagram
  • Optical Power Meter Interface: For connecting fiber optic cables to measure optical power.
  • LED žibintuvėlis: Provides illumination for working in dark areas.
  • C tipo įkrovimo prievadas: Naudojamas vidinei baterijai įkrauti.
  • Network Cable Test Port: For connecting network cables (RJ45) to test wire order and signal.
  • Cable Test Module: A detachable module used in conjunction with the Network Cable Test Port.
  • Red Light Source Port: Output for the Visual Fault Locator (VFL).
  • Ekranas: LCD screen showing measurement readings, wavelength, battery status, and other information.
  • Klaviatūra: Buttons for ON/OFF, VFL activation, wavelength selection, saving data, and reference setting.

4. Specifikacijos

The following table details the technical specifications for the UT693A series models:

Table of product specifications for UT693A-C01, UT693A-C30, UT693A-T01, UT693A-T30 models.
4.1 pav.: Produkto specifikacijų lentelė
FunkcijaUT693A-C01 / UT693A-C30UT693A-T01 / UT693A-T30
Meter/Laser PortC-type (-50~+30dBm)T-type (-70~+10dBm)
Tikslumas*±0.4dB (1310nm/1490nm/1550nm/1625nm)
±1dB (850nm/1300nm/980nm/1270nm/1577nm/1650nm)
±0.2 dB (1550nm)
±0.3dB (1310nm/1490nm/1625nm)
±1dB (850nm/1300nm/980nm/1270nm/1577nm/1650nm)
Kalibravimo bangos ilgis850nm/980nm/1270nm/1300nm/1310nm/1490nm/1550nm/1577nm/1625nm/1650nm
Meter/Laser Port2.5mm universal interface
Detektoriaus tipas„InGaAs“
Rezoliucija0.01dBm
Fiber frequency270Hz/330Hz/1KHz/2KHz
Wave Memory
Auto Cal
LED žibintuvėlis
Foninis apšvietimas
Lazerio galia1mW (C01), 30mW (C30)1mW (T01), 30mW (T30)
Raudonos šviesos bangos ilgis650 nm ± 20 nm
Raudonos šviesos režimasCW/2 ± 1Hz flicker
Network cable sequence detection interfaceRJ45 sąsaja
Įkrovimo sąsajaC tipo sąsaja
Duomenų saugojimas500 komplektai
Maitinimas3.7 V 450 mAh ličio baterija
Darbo aplinka-10 ~ 50°C, <90%RH
Sandėliavimo aplinka-20 ~ 45°C, 65 ± 20%RH
Produkto svoris~95g
Produkto dydis100 mm x 59 mm x 28 mm

*Test Conditions: 23°C ± 2°C, 40 ~ 60% RH, FC/PC connector.
Type T Accuracy Range: -60 dBm to +3 dBm, otherwise refer to: ±0.8 dB; +3 dBm to +6 dBm, -65 dBm to -60 dBm @1550 nm test wavelength ±3.0 dB; +6 dBm to +10 dBm, -70 dBm to -65 dBm @1550 nm test wavelength.
Type C Accuracy Range: -40 dBm to +23 dBm, otherwise refer to: ±0.8 dB; +23 dBm to +26 dBm, -45 dBm to -40 dBm @1550 nm test wavelength ±3.0 dB; +26 dBm to +30 dBm, -50 dBm to -45 dBm @1550 nm test wavelength.

5. Sąranka

5.1 Įrenginio įkrovimas

The UT693A series devices are equipped with a built-in 3.7V 450mAh lithium battery. Before initial use, or when the battery indicator on the display shows low power, charge the device using the provided Type-C charging cable.

  1. Connect one end of the Type-C charging cable to the Type-C Charging Port on the device.
  2. Connect the other end of the cable to a USB power source, such as a power bank, computer USB port, or car USB charger.
  3. The device display will indicate charging status. Ensure the device is fully charged for optimal performance.
Image showing the UNI-T UT693A device connected via a Type-C cable to a power bank for charging.
Figure 5.1: Charging the UT693A

5.2 Įjungimas / išjungimas

Paspauskite ir palaikykite ĮJUNGTA/IŠJUNGTA button located on the keypad to power the device on or off.

6. Naudojimo instrukcijos

6.1 Optical Power Measurement

This function measures the optical power of fiber optic signals.

  1. Įjunkite įrenginį.
  2. Connect the fiber optic cable to the Optical Power Meter Interface (2.5mm universal interface).
  3. Paspauskite Bangos ilgis button to cycle through the available calibration wavelengths (850nm, 980nm, 1270nm, 1300nm, 1310nm, 1490nm, 1550nm, 1577nm, 1625nm, 1650nm) until the desired wavelength is selected.
  4. The display will show the measured optical power in dBm and mW.
  5. To set a reference value, press and hold the REF button. The current reading will be set as the 0dB reference.
  6. To save a reading, press and hold the >2s Save button. The device can store up to 500 sets of data.
Image showing the UNI-T UT693A device measuring optical power with a fiber optic cable connected.
Figure 6.1: Optical Power Measurement in Progress

6.2 Visual Fault Locator (VFL) / Red Light Source

The VFL function uses a strong red light to quickly identify fiber breaks, bends, and dirty connectors.

  1. Įjunkite įrenginį.
  2. Connect the fiber optic cable to the Red Light Source Port.
  3. Paspauskite VFL button to activate the red light source.
  4. Observe the fiber for any visible red light leakage, which indicates a fault.
  5. Paspauskite VFL button again to cycle between Continuous Wave (CW) mode and 2 ± 1Hz flicker mode, or to turn off the VFL.
Image showing the UNI-T UT693A device using its red light source (VFL) to detect a fault in a fiber optic cable within a network cabinet.
Figure 6.2: Using the VFL to Detect Fiber Faults

6.3 Tinklo kabelio testavimas

The device can test the wire order and signal of RJ45 network cables.

  1. Įjunkite įrenginį.
  2. Connect one end of the RJ45 network cable to the Network Cable Test Port on the main unit.
  3. Connect the other end of the network cable to the detachable Cable Test Module.
  4. The device will automatically begin testing the wire order and signal. The display will show the test results.
Image showing the UNI-T UT693A device connected to a remote cable test module via an RJ45 cable for network cable testing.
Figure 6.3: Network Cable Testing Setup

6.4 LED žibintuvėlis

To activate the built-in LED flashlight, press the Žibintuvėlio piktograma button on the keypad. Press it again to turn off the flashlight. This feature is useful for illuminating dark work areas.

Image showing the UNI-T UT693A device with its LED flashlight activated, illuminating a bundle of network cables in a dark space.
Figure 6.4: Using the LED Flashlight

6.5 Auto Calibration (Self-Adjust)

The auto-calibration feature helps in setting loss/gain and showing true values for faster testing. The offset range is [-5,5]dB.

  1. Įsitikinkite, kad įrenginys įjungtas.
  2. Connect a known stable optical signal to the Optical Power Meter Interface.
  3. Paspauskite ir palaikykite Auto Cal button (if available, or follow specific instructions in the full manual for calibration mode) to initiate self-adjustment. The device will automatically set the loss/gain.
Image showing the UNI-T UT693A device display during auto-calibration, showing '850nm' and '5.0 dB'.
Figure 6.5: Auto Calibration Feature

6.6 Duomenų registravimas

The UT693A can store up to 500 sets of power readings for later review.

  1. During an optical power measurement, once a stable reading is obtained, press and hold the >2s Save mygtuką.
  2. The device will save the current reading. Refer to the full user manual for instructions on how to access and review saugomus duomenis.
Image showing the UNI-T UT693A display with multiple data logs overlaid, indicating the 500 data logs feature.
Figure 6.6: Data Logging Capability

7. Priežiūra

7.1 Valymas

  • Nuvalykite įrenginio išorę minkštu, sausu skudurėliu.
  • Pritvirtinusius nešvarumus naudokite šiek tiek damp šluostę su švelniu plovikliu, tada nusausinkite.
  • Nenaudokite abrazyvinių valiklių ar tirpiklių.
  • Keep the optical ports clean. Use specialized fiber optic cleaning tools (e.g., lint-free wipes and isopropyl alcohol) to clean the optical interfaces before and after use to ensure accurate measurements.

7.2 Akumuliatoriaus priežiūra

  • Recharge the device when the battery indicator is low to prolong battery life.
  • If storing the device for an extended period, charge it to approximately 50% every few months.
  • Nelaikykite prietaiso ekstremaliose temperatūrose.

7.3 Saugykla

  • Prietaisą laikykite vėsioje, sausoje vietoje, toliau nuo tiesioginių saulės spindulių ir ekstremalių temperatūrų.
  • Use the original packaging or a protective case to prevent damage.

8. Problemų sprendimas

ProblemaGalima priežastisSprendimas
Įrenginys neįsijungia.Low battery or depleted battery.Įkraukite įrenginį naudodami C tipo laidą.
Inaccurate optical power readings.Dirty optical connector/port; incorrect wavelength selected; fiber damage.Clean optical connectors. Ensure correct wavelength is selected. Check fiber for damage using VFL. Perform auto-calibration.
VFL red light is dim or not visible.Dirty VFL port; fiber not properly connected; VFL not activated.Clean the VFL port. Ensure fiber is securely connected. Press the VFL button to activate.
Network cable test fails or shows incorrect wiring.Faulty cable; improper connection to test module; damaged RJ45 port.Ensure both ends of the cable are securely connected to the main unit and the remote module. Test with a known good cable. Replace faulty cable if necessary.
Ekranas tuščias arba nereaguoja.Įrenginys užstrigo; išsikrovęs akumuliatorius.Try powering off and on again. If unresponsive, charge the device. If problem persists, contact support.

9. Vartotojo patarimai

  • Laikykite jungtis švarias: Fiber optic connectors are highly sensitive to dust and dirt. Always use appropriate cleaning tools and caps to protect the ports when not in use.
  • Verify Wavelength: When performing optical power measurements, ensure the selected wavelength on the device matches the wavelength of the signal being tested for accurate results.
  • Naudokite duomenų registravimą: For projects requiring multiple measurements or historical data, make use of the 500-set data logging feature to track performance over time.
  • Nešiojama galia: The USB Type-C charging allows for convenient charging on the go. Consider carrying a small power bank for extended field work.
  • Flashlight for Efficiency: Don't underestimate the built-in LED flashlight. It can significantly improve efficiency and safety when working in dimly lit network cabinets or server rooms.

10. Garantija ir palaikymas

For warranty information, technical support, or service inquiries, please refer to the Certificate & Warranty Card included in your product package or contact UNI-T customer service directly. Keep your purchase receipt as proof of purchase for warranty claims.

Dokumentai - UNI-T – UT693A

nėra atitinkamų dokumentų