1. Įvadas
The AT1-4000X Variable Frequency Drive (VFD) is designed to provide precise speed control for 3-phase 4kW AC motors, operating from a single-phase 220V AC input. This VFD utilizes a unique control method to achieve high torque, high accuracy, and a wide speed regulating range, ensuring high performance in various applications.
Pagrindinės funkcijos:
- Excellent anti-trip performance and adaptability to challenging power conditions, temperature fluctuations, humidity, and dust interference, significantly enhancing stability.
- Optimized PWM control technology and electromagnetic compatibility for low noise and reduced electromagnetic interference.
- User-friendly design for easy operation and wiring.
- Fast start and stop response with substantial torque at low speeds.
2. Saugos priemonės
Failure to follow these instructions may result in death, serious injury, or significant property loss.
- Prieš atlikdami bet kokius laidų prijungimo ar priežiūros darbus, visada įsitikinkite, kad maitinimo šaltinis yra atjungtas.
- Never connect the U/V/W output terminals to the AC power supply. Doing so will cause severe damage to the inverter.
- Do not install the inverter in environments with flammable or explosive gases, as this poses a risk of explosion.
- The ground terminal (GND) of the inverter must be properly and securely grounded.
- Only qualified professionals should perform internal wiring or open the inverter's casing due to the presence of high voltage.

3. Produktas baigtasview
The AT1-4000X VFD features a clear digital display and an intuitive control panel for easy monitoring and adjustment of motor parameters. The unit is designed for efficient heat dissipation with integrated cooling fins and fans.
3.1 Valdymo skydas
Priekiniame skydelyje yra:
- Skaitmeninis ekranas: Shows operational parameters such as frequency (Hz), forward/reverse status (FWD/REV), and revolutions per minute (r/min).
- Rodikliai: Power, Hz, FWD, REV, r/min.
- Mygtukai:
DISP: Display mode selection.PROG: Program mode entry/exit.FUNC/DATA: Function/Data entry.FWD/REV: Forward/Reverse direction control.▲(Up Arrow): Increase value or navigate menus.▼(Down Arrow): Decrease value or navigate menus.RUN: Start motor operation.STOP/RESET: Stop motor operation or reset errors.
- Sukamoji rankenėlė: For fine adjustment of frequency or parameter values.
3.2 terminalų
The VFD is equipped with clearly labeled terminals for power input and motor output.

4. Specifikacijos
| Funkcija | Specifikacija |
|---|---|
| Modelis | AT1-4000X |
| Įvertintas ttage (įvestis) | AC 220V (Single Phase) |
| Suitable Motor Power | 4 kW |
| Kontrolės metodas | V/F Open Loop |
| Išėjimas ttage Adjustable Method | PWM valdymas |
| Nominali išėjimo srovė | 20A |
| Maximum Output Frequency Range | 0–400 Hz |
| Tipas | Inverter Motor Drive |
| Kilmė | Žemyninė Kinija |
| Pakuotės matmenys (I x P x A) | 23 cm x 23 cm x 16 cm |
| Pakuotės svoris | 1.498 kg |
5. Sąranka
Before proceeding with installation and wiring, ensure all safety precautions are understood and followed. Installation should be performed by qualified personnel.
5.1 Diegimo aplinka
- Install the VFD in a clean, dry, and well-ventilated area.
- Avoid direct sunlight, high temperatures, excessive humidity, and dusty environments.
- Ensure there is sufficient space around the unit for proper heat dissipation.
- Do not install near flammable or explosive materials.
5.2 Laidų prijungimo instrukcijos
The VFD is designed for simple wiring. Always ensure the power supply is OFF before connecting any wires. Connect wires after removing the terminal screws.

| Terminalas | Funkcija | Aprašymas |
|---|---|---|
| L, N | AC 220V įvestis | Connect to single-phase AC 220V power supply. |
| U, V, W | 3-Phase AC Motor Output | Connect to the three-phase AC motor terminals. |
| GND | Žemė | Connect to a reliable earth ground. |
6. Naudojimo instrukcijos
Once the VFD is correctly installed and wired, you can begin operation. Familiarize yourself with the control panel functions.
6.1 Pagrindinės operacijos
- Maitinimas: Ensure all connections are secure, then apply single-phase 220V AC power to the L and N terminals. The VFD display should illuminate.
- Variklio užvedimas: Paspauskite
RUNbutton to start the motor. The FWD or REV indicator will light up depending on the current direction setting. - Dažnio / greičio reguliavimas: Use the rotary knob to adjust the output frequency, which in turn controls the motor speed. The display will show the current frequency (Hz) or RPM (r/min).
- Keisti kryptį: Paspauskite
FWD/REVbutton to toggle the motor's rotation direction. - Variklio sustabdymas: Paspauskite
STOP/RESETmygtuką varikliui sustabdyti.
6.2 Parametrų programavimas
The PROG ir FUNC/DATA buttons, along with the arrow keys (▲, ▼), are used to access and modify various operating parameters. Refer to the detailed programming manual (if available) for specific parameter settings relevant to your application.
- Paspauskite
PROGto enter or exit programming mode. - Naudokite
▲ir▼to navigate through parameter groups or individual parameters. - Paspauskite
FUNC/DATAto select a parameter for editing or to confirm a value. - Use the rotary knob or arrow keys to change the parameter value.
- Paspauskite
FUNC/DATAdar kartą, kad išsaugotumėte naują reikšmę.
7. Priežiūra
Regular maintenance helps ensure the longevity and reliable operation of your VFD.
- Valymas: Laikykite dažnio keitiklių įrenginį švarų, be dulkių ir šiukšlių. Valymui naudokite minkštą, sausą šluostę. Nenaudokite skystų valiklių.
- Vėdinimas: Ensure that the cooling fans and ventilation openings are not obstructed to prevent overheating.
- Patikra: Periodically inspect all wiring connections for tightness and signs of wear or damage.
- Profesionalus aptarnavimas: Due to high internal voltages, any internal inspection or repair should only be performed by qualified service personnel. Do not attempt to open the VFD casinpats sau.
8. Problemų sprendimas
Šiame skyriuje pateikiamos bendros gairės, kaip išspręsti dažniausiai kylančias problemas. Sudėtingesnėms problemoms spręsti kreipkitės į techninę pagalbą.
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| VFD neįsijungia | No input power; Incorrect wiring | Check power supply and input wiring (L, N). |
| Variklis neveikia | Motor wiring incorrect; VFD in STOP mode; Parameter error | Verify motor wiring (U, V, W); Press RUN; Check programmed parameters. |
| Variklio greitis nestabilus | Incorrect V/F settings; Motor load fluctuations | Adjust V/F curve parameters; Ensure motor is suitable for load. |
| Perkrovos klaida | Motor overloaded; Incorrect overload protection setting | Reduce motor load; Check and adjust overload protection parameters. |
If an error occurs, the VFD display may show an error code. Press the STOP/RESET button to clear the error after addressing the cause.
9. Vartotojo patarimai
- For optimal performance, ensure the VFD is matched correctly to your motor's power rating (e.g., 4kW motor for this 4kW VFD).
- When adjusting frequency, make gradual changes to avoid sudden motor stress.
- Always ensure proper grounding to prevent electrical hazards and ensure stable operation.
- Keep the VFD's ventilation clear to prevent overheating, especially during continuous operation.
10. Garantija ir palaikymas
For warranty information, technical support, or service inquiries, please refer to the documentation provided at the point of purchase or contact the seller directly. Keep your purchase records handy when seeking support.