Truma 37011

Truma LevelCheck Gas Level Indicator

Modelis: 37011

Įvadas

The Truma LevelCheck is an innovative and reliable device designed to measure the filling level of gas cylinders quickly and accurately using ultrasound technology. This compact, handheld unit provides instant readings, indicating whether there is gas present at the point of measurement. It is an essential tool for anyone using steel and aluminum LPG cylinders, ensuring you always know your gas supply status.

Truma LevelCheck device

Figure 1: Truma LevelCheck Gas Level Indicator

Sąranka

The Truma LevelCheck is designed for immediate use right out of the box. No complex setup or calibration is required.

Akumuliatoriaus montavimas

The device comes with pre-installed batteries. If replacement is needed, open the battery compartment located on the side of the device and insert new batteries according to the polarity indicators.

Pradinis patikrinimas

Before first use, ensure the device is clean and free of debris, especially the measurement head. The integrated LED indicator and torch should function when the device is pressed against a surface.

Truma LevelCheck packaging

Figure 2: Truma LevelCheck in its packaging, ready for use.

Naudojimo instrukcijos

The Truma LevelCheck provides a simple and quick way to determine the gas level in your cylinder.

Matavimo procedūra

  1. Ensure the gas cylinder is upright and stable.
  2. Hold the Truma LevelCheck horizontally against the side of the gas cylinder. It is crucial to hold the device at a 90-degree angle to the cylinder surface for accurate readings.
  3. Press the measurement head firmly against the cylinder wall. The device will automatically activate and perform a measurement.
  4. Stebėkite LED indikatorių:
    • Žalia šviesa: Indicates that there is gas present at the point of measurement.
    • Raudona šviesa: Indicates that there is no gas present at the point of measurement.
  5. Move the device up or down the cylinder to find the transition point where the light changes from green to red. This point indicates the current gas level.
  6. The device automatically switches off after a few seconds of inactivity to conserve battery life.
Diagram showing Truma LevelCheck indicating gas presence with green light and no gas with red light

Figure 3: Gas level indication with green (gas present) and red (no gas) lights.

Hand holding Truma LevelCheck against a gas cylinder outdoors

Figure 4: Proper positioning of the LevelCheck on a gas cylinder.

Integrated Torch Function

The Truma LevelCheck features an integrated LED torch, useful for checking gas levels in low-light conditions or at night. The torch activates automatically when the device is in use.

Svarbūs svarstymai

Truma LevelCheck being used on gas cylinders, highlighting fast measurement, LED indication, and portability

5 pav.: Pagrindiniai privalumaitages of the Truma LevelCheck.

Produktas baigtasview Vaizdo įrašas

1 vaizdo įrašas: Oficialus produktas baigtasview of the Truma LevelCheck. This video demonstrates the ease of use and key features of the device, including how to take a measurement and the function of the LED indicator and built-in torch.

Priežiūra

To ensure the longevity and accurate performance of your Truma LevelCheck, follow these simple maintenance guidelines:

Trikčių šalinimas

If you encounter issues with your Truma LevelCheck, refer to the following common problems and solutions:

ProblemaGalima priežastisSprendimas
Device does not turn on or LED does not light up.Low or dead batteries; improper battery installation; measurement head not pressed firmly enough.Replace batteries; check battery polarity; press the measurement head firmly against the cylinder surface.
Netikslūs arba nenuoseklūs rodmenys.Cylinder surface is dirty, rusty, or icy; device not held at 90-degree angle; attempting to measure non-compatible cylinder types.Clean the cylinder surface; ensure the device is held perpendicular to the cylinder; verify cylinder material and diameter compatibility (steel/aluminum, 8-14 inch diameter).
LED always shows red.Cylinder is empty; measurement taken above the gas level; non-compatible cylinder.Move the device lower on the cylinder; ensure cylinder contains gas; check cylinder compatibility.

Specifikacijos

FunkcijaDetalė
Modelis37011
MedžiagaNerūdijantis plienas
Matmenys (I x P x A)5.43 x 1.38 x 1.18 colio (13.8 x 3.5 x 3.0 cm)
Svoris6.4 uncijos (181 g)
Ekrano dydis3.5 Centimeters (LED indicator area)
Compatible Cylinder TypesSteel and Aluminum LPG cylinders
Compatible Cylinder Diameters8–14 colių (200–350 mm)
Darbinės temperatūros diapazonas5 °F to 104 °F (-15 °C to +40 °C)
SavybėsUltrasonic measurement, LED indicator (green/red), Integrated LED torch, Automatic shut-off

Garantija ir palaikymas

Truma is committed to providing high-quality products and excellent customer service. For specific warranty details, please refer to the warranty card included with your product or visit the official Truma websvetainę.

For technical support, troubleshooting assistance beyond this manual, or spare parts inquiries, please contact Truma North America customer service. Contact information can typically be found on the product packaging or the official Truma websvetainę.

Internetiniai ištekliai:

Susiję dokumentai - 37011

Preview „Truma UltraRapid“ suskystintų dujų ir elektrinis vandens šildytuvas: naudojimo instrukcija ir specifikacijos
Šiame vadove pateikiamos išsamios „Truma UltraRapid“ suskystintų dujų ir 230 V / 240 V elektrinio vandens šildytuvo, skirto nameliams ant ratų ir kemperiams, naudojimo instrukcijos, saugos gairės, techninės priežiūros procedūros, gedimų paieškos patarimai, techninės specifikacijos ir garantijos informacija.
Preview Truma CP plus naudojimo instrukcija
Išsamios „Truma CP plus“ valdymo skydelio naudojimo instrukcijos, kuriose išsamiai aprašomos jo funkcijos, nustatymas ir trikčių šalinimas, skirti „Truma Combi“ ir „Aventa“ prietaisams.
Preview „Truma CP plus Panel de Control Digital“: valdymo ir montavimo vadovas
Skaitmeninio „Truma CP plus“ valdymo skydelio vadovas, išsamiai su operacijomis, instaliacijomis, saugikliais ir problemų sprendimo būdais „Truma Combi en vehículos recreativos“.
Preview „Truma AquaGo AU“ suskystintų dujų momentinio vandens šildytuvas: naudojimo instrukcija
Išsamios „Truma AquaGo AU“ suskystintų dujų momentinio vandens šildytuvo, skirto kemperiams (RV), naudojimo instrukcijos ir saugos gairės. Sužinokite apie įrengimą, naudojimą, priežiūrą ir trikčių šalinimą.
Preview „Truma CP plus“ naudojimo instrukcijos ir trikčių šalinimo vadovas
Išsamios „Truma CP plus“ valdymo skydelio naudojimo instrukcijos ir trikčių šalinimo vadovas, apimantis „Combi“ dujinių ir dyzelinių šildytuvų bei oro kondicionavimo sistemų įrengimą, valdymą, funkcijas ir gedimų diagnostiką.
Preview Truma CP plus Bedienungsanleitung
Umfassende Bedienungsanleitung für das Truma CP plus Bedienfeld zur Steuerung von Heizungs- und Klimasystemen in Wohnmobilen und Caravans. Enthält Anleitungen, Funktionen und Fehlerbehebung.