This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Pentair 263038 1-1/2-Inch 2-Way PVC Diverter Valve. This valve is designed for diverting, shut-off, or mixing applications in various plumbing systems, particularly in pool and spa environments. Please read these instructions thoroughly before installation and use.

2. Saugos informacija

ĮSPĖJIMAS: Always disconnect power to pumps and other equipment before working on any plumbing system. Failure to do so may result in serious injury or death.

ATSARGIAI: This valve is designed for specific applications. Ensure it is compatible with your system's pressure and chemical requirements. Maximum pressure rating is 150 PSI.

  • Montavimo ir techninės priežiūros metu dėvėkite tinkamas asmenines apsaugos priemones (AAP).
  • Įsitikinkite, kad visos jungtys yra sandariai uždarytos, kad išvengtumėte nuotėkio.
  • Do not overtighten fittings, as this can damage the valve body.
  • Laikyti vaikams nepasiekiamoje vietoje.

3. Produktas baigtasview

The Pentair 263038 is a robust 1-1/2-inch 2-way diverter valve constructed from durable PVC or CPVC material. It features a high flow rate design and a fiberglass-reinforced handle for reliable operation. The valve is equipped with a maintenance-free Teflon coated diverter seal, ensuring optimum positive sealing and longevity.

Pagrindinės funkcijos:

  • Available in PVC or CPVC construction.
  • Maintenance-free Teflon coated diverter seal for reliable performance.
  • Optimum positive-seal mechanism.
  • Designed for high flow rate applications.
  • Features a fiberglass reinforced handle for durability.
  • Withstands pressure up to 150 PSI.
  • Chemical-resistant for various applications.
  • Field-adjustable stop positions for precise control.
  • Can be plumbed with the inlet at any port.

Komponento identifikavimas:

Iš viršaus į apačią view of Pentair 263038 diverter valve with handle
3.1 paveikslas: Iš viršaus į apačią view of the Pentair 263038 diverter valve, showing the handle and port markings. The handle allows for selection of flow direction or shut-off.
Direct top view of Pentair 263038 diverter valve showing 'OFF' position
3.2 paveikslas: Direct top view of the valve, highlighting the "OFF" position indicator and the various port settings around the handle base. This view clearly shows the rotational mechanism.
Šoninė view of Pentair 263038 diverter valve
3.3 paveikslas: Šoninė view of the diverter valve, illustrating the main body and the two primary ports for plumbing connections. The robust construction is visible.
Pabaiga view of Pentair 263038 diverter valve showing one 1-1/2 inch port
3.4 paveikslas: Pabaiga view of the valve, showing one of the 1-1/2 inch connection ports. This port is designed for solvent welding to standard PVC or CPVC piping.

4. Sąranka ir diegimas

Proper installation is crucial for the optimal performance and longevity of your diverter valve. This valve is designed for 1-1/2-inch plumbing connections.

4.1 Kontrolinis sąrašas prieš diegimą:

  • Verify that the valve material (PVC or CPVC) is compatible with your existing plumbing and the chemicals used in your system.
  • Ensure you have all necessary tools and materials, including PVC/CPVC cement, primer, measuring tape, and pipe cutters.
  • Confirm that the installation location allows for easy access to the valve handle for operation and future maintenance.

4.2 Diegimo veiksmai:

  1. Plan Plumbing Layout: Determine the desired flow path for diverting, mixing, or shut-off applications. The valve can be plumbed with the inlet at any port.
  2. Paruoškite vamzdžius: Cut the existing or new pipes to the correct length, ensuring clean, straight cuts. Deburr the edges of the pipes.
  3. Sausas pritaikymas: Temporarily fit the valve and pipes together without cement to ensure proper alignment and fit. Mark the pipes and valve for correct orientation.
  4. Užtepkite gruntą ir cementą: Apply PVC/CPVC primer to both the outside of the pipe and the inside of the valve port. Follow immediately with a generous, even coat of PVC/CPVC cement to both surfaces.
  5. Join Connections: Quickly insert the pipe into the valve port with a quarter-turn twist until it bottoms out. Hold firmly for 30 seconds to allow the cement to set.
  6. Repeat for all Ports: Connect all necessary pipes to the valve ports using the same priming and cementing procedure.
  7. Kietėjimo laikas: Allow adequate cure time for the cement as recommended by the cement manufacturer before pressurizing the system.
  8. Adjust Stop Positions (Optional): The valve features field-adjustable stop positions. If specific flow limits are required, consult the markings on the valve top and adjust the internal stops as needed using a screwdriver.

Pastaba: For detailed instructions on solvent welding, refer to the specific PVC/CPVC cement manufacturer's guidelines.

5. Naudojimo instrukcijos

The Pentair 263038 diverter valve allows for easy control of water flow. The fiberglass-reinforced handle is used to select the desired flow path.

5.1 Understanding Valve Positions:

The top of the valve features markings and a rotating handle. The handle's position indicates the active flow path. Common positions include:

  • Diverting: Directs water from one inlet to one of two outlets, or from two inlets to one outlet.
  • Išjungti: Completely stops flow through the valve. This is typically indicated by an "OFF" marking on the valve body.
  • Maišymas: Combines flow from two inlets into a single outlet.

Rotate the handle to align with the desired port or function indicated on the valve body. The field-adjustable stops can be set to limit the handle's rotation to specific positions if needed.

5.2 Bendras veikimas:

  1. Ensure the system is not under excessive pressure before adjusting the valve, especially if making significant changes to flow.
  2. Grasp the fiberglass-reinforced handle firmly.
  3. Rotate the handle to the desired position. The handle should move smoothly.
  4. Verify the flow change in your system.

Pastaba: If the handle feels stiff, do not force it. Refer to the Maintenance section for lubrication or inspection.

6. Priežiūra

The Pentair 263038 diverter valve is designed for minimal maintenance due to its maintenance-free Teflon coated diverter seal. However, periodic inspection and occasional servicing can extend its lifespan.

6.1 Routine Inspection:

  • Periodically check for any signs of leaks around the valve body or connections.
  • Inspect the handle for any damage or excessive wear.
  • Ensure the handle rotates smoothly between positions.

6.2 Servicing (If Required):

While the Teflon seal is maintenance-free, if the valve becomes stiff to operate or develops a leak from the stem, it may be serviceable. The valve can typically be disassembled by removing the screws on the top cover. This allows access to the diverter and seals for cleaning or replacement if necessary. Use only manufacturer-approved lubricants for O-rings and seals if reassembly is performed.

ATSARGIAI: Disassemble the valve only if you are comfortable with plumbing repairs. Ensure the system is depressurized and drained before attempting any servicing.

7. Problemų sprendimas

This section addresses common issues you might encounter with your diverter valve.

ProblemaGalima priežastisSprendimas
Vožtuvų nuotėkiai jungtyseImproper solvent welding; cracked pipe or fitting.Ensure proper application of primer and cement during installation. If leaking persists, the connection may need to be cut out and re-plumbed.
Valve Leaks from Handle/Stem AreaWorn or damaged internal seals (O-rings).The valve may require disassembly to inspect and replace internal seals. Contact a qualified technician if unsure.
Rankena standi arba sunkiai pasukamaAccumulation of debris; lack of lubrication on internal seals; overtightened components.Disassemble the valve (if comfortable) to clean out debris and apply a silicone-based lubricant to the diverter and O-rings. Ensure screws are tightened appropriately, not excessively.
Incomplete Flow DiversionHandle not fully seated in position; internal debris obstructing flow.Ensure the handle is rotated completely to the desired stop position. If the issue persists, inspect the internal mechanism for obstructions.

8. Specifikacijos

Detailed technical specifications for the Pentair 263038 1-1/2-Inch 2-Way PVC Diverter Valve.

AtributasDetalė
Modelio numeris263038
Prekės ženklasPentair
MedžiagaPVC or CPVC
Išorinė apdailaPVC or CPVC
Prievadų skaičius2
Įleidimo angos dydis1.5 colių
Išvado jungties dydis1.5 colių
Maksimalus slėgis150 PSI
Prekės matmenys (I x P x A)7 x 7 x 6 colio
Prekės svoris1.5 svaro
GamintojasPENTAIR vandens baseinas ir SPA, IN
UPC788379644352, 797267286857, 718472683019, 797267790163

9. Garantija ir palaikymas

For specific warranty information regarding your Pentair 263038 diverter valve, please refer to the documentation included with your purchase or visit the official Pentair websvetainėje. Garantijos sąlygos gali skirtis.

For technical support, replacement parts, or further assistance, please contact Pentair customer service directly. Contact information can typically be found on the Pentair websvetainėje arba ant jūsų produkto pakuotės.

Pentair oficialus Websvetainė: www.pentair.com

Susiję dokumentai - 263038

Preview „Pentair“ automatinio apėjimo vožtuvo komplekto (P/N 462048) montavimo instrukcijos
Išsamus „Pentair“ automatinio apėjimo vožtuvo komplekto (P/N 462048), skirto „MasterTemp“ ir „Max-E-Therm“ baseinų ir SPA šildytuvams, montavimo vadovas. Apima esminius saugos įspėjimus, perkrovos instrukcijas.view sistemos privalumų, išsamios santechnikos ir pavaros montavimo nustatymo procedūros bei nuoseklios instrukcijos, kaip konfigūruoti pradinę ir galinę padėtis optimaliai baseino hidraulikai.
Preview „Pentair T40-FN“ automatinis baseino užpildymo įrenginys baseinams su nykstančiais kraštais – montavimo vadovas
Sužinokite apie automatinį baseinų užpildymo įrenginį „Pentair T40-FN“, skirtą baseinams su nykstančiais kraštais. Šiame vadove pateikiama išsami įrengimo informacija ir saugos įspėjimai, užtikrinantys tinkamą integravimą su gaudykle.asins ir armatūra.
Preview „Pentair MagicStream Laminar“: įrengimo, naudojimo ir saugos vadovas
Išsamus vadovas, skirtas „Pentair MagicStream Laminar“, 12 V kintamosios srovės LED vandens elemento, skirto baseinams ir SPA, įrengimui, naudojimui ir priežiūrai. Apima saugą, elektros jungtis, valdymo sistemos integravimą ir trikčių šalinimą.
Preview Pentair Tag„Elus“ smėlio filtro įrengimo ir naudojimo vadovas
Išsamus „Pentair“ įrengimo, naudojimo, priežiūros ir trikčių šalinimo vadovas Tag„Elus“ smėlio filtrai ir „HiFlow“ 6 padėčių vožtuvai. Į komplektą įeina saugos instrukcijos, atsarginės dalys ir techninės specifikacijos.
Preview „Pentair IntelliChlor®“ druskos ir chloro generatoriaus IC15, IC20, IC40, IC60 įrengimo ir naudojimo instrukcija
Išsamus „Pentair IntelliChlor®“ druskos ir chloro generatoriaus modelių IC15, IC20, IC40 ir IC60 įrengimo ir naudojimo vadovas. Apima saugą, įrengimą, eksploatavimą, priežiūrą, vandens cheminę medžiagą ir trikčių šalinimą gyvenamųjų namų baseinų sanitarijos srityje.
Preview „Pentair IntelliBrite“ architektūrinės serijos baseinų ir SPA šviestuvų montavimo ir naudojimo vadovas
Šiame vadove pateikiamos išsamios „Pentair IntelliBrite Architectural“ serijos baseinų ir SPA šviestuvų įrengimo, naudojimo ir priežiūros instrukcijos, apimančios saugą, elektros reikalavimus, veikimo režimus ir keičiamas dalis.