Wayne CDU980E

Wayne CDU980E 3/4 HP Submersible Sump Pump

Instrukcijų vadovas

1. Įvadas

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Wayne CDU980E 3/4 HP Submersible Sump Pump. Please read all instructions carefully before use and retain this manual for future reference.

Wayne CDU980E 3/4 HP Submersible Sump Pump with integrated vertical float switch.

Figure 1: Wayne CDU980E 3/4 HP Submersible Sump Pump

2. Saugos informacija

WARNING: Risk of electric shock. This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of electric shock, be certain that it is connected only to a properly grounded grounding-type receptacle.

3. Pakuotės turinys

Patikrinkite, ar yra visi komponentai ir ar jie nepažeisti:

4. Pagrindinės savybės

Diagram highlighting key features of the Wayne CDU980E sump pump, including stainless steel construction and vertical float switch.

Figure 2: Key Features of the Wayne CDU980E

5. Sąranka ir diegimas

The Wayne CDU980E sump pump is designed for installation in 11-inch diameter or larger sump pits. Follow these steps for proper installation:

  1. Prepare the Sump Pit: Ensure the sump pit is clean and free of debris. The pump should sit on a solid, level surface.
  2. Connect Discharge Pipe: Thread a 1-1/2 inch NPT discharge pipe into the pump's outlet. Use appropriate sealant for a watertight connection.
  3. Įdiekite atbulinį vožtuvą: Install a check valve in the discharge line above the pump to prevent water from flowing back into the sump pit when the pump shuts off.
  4. Padėkite siurblį: Carefully lower the pump into the sump pit. Ensure the float switch can move freely without obstruction from the pit walls or other pipes.
  5. Elektros jungtis: Plug the pump into a properly grounded 120V, 60Hz electrical outlet protected by a GFCI. Ensure the power cord is routed to prevent damage.
  6. Bandomoji operacija: Pour water into the sump pit to verify the float switch activates the pump and discharges water correctly.
Diagram showing a submersible sump pump installed in a sump pit with discharge pipe and electrical connection.

Figure 3: Typical Sump Pump Installation

Diegimas baigtasview Vaizdo įrašas

1 vaizdo įrašas: metimas per sekundęview of a similar Wayne sump pump, demonstrating its features and installation considerations. This video is provided by the manufacturer.

6. Naudojimo instrukcijos

The Wayne CDU980E operates automatically via its integrated vertical float switch. When water in the sump pit rises and lifts the float to the 'ON' level (approximately 9 inches), the pump will activate and begin discharging water. Once the water level drops and the float returns to the 'OFF' level (approximately 4 inches), the pump will shut off. This automatic operation ensures your basement remains dry without constant manual intervention.

Close-up of the Wayne CDU980E sump pump label showing model number and electrical specifications.

Figure 4: Wayne CDU980E Sump Pump Label

7. Priežiūra

Regular maintenance helps ensure the longevity and reliable operation of your sump pump:

8. Problemų sprendimas

ProblemaGalima priežastisSprendimas
Siurblys neveikiaNo power; tripped GFCI; stuck float switch; motor failure.Check power supply and GFCI. Clear float switch. Consult a qualified technician for motor issues.
Siurblys dirba nuolatStuck float switch; check valve failure; continuous water inflow.Clear float switch. Inspect/replace check valve. Address source of continuous water.
Pump runs but no water dischargesClogged intake or discharge pipe; air lock; low water level.Clear obstructions. Ensure pump is fully submerged. Check for weep hole (not needed for this model, but common issue).
Siurblys triukšmingai veikia arba per daug vibruojaDebris in impeller; pump not stable; worn bearings.Disconnect power and inspect impeller for debris. Ensure pump is on a stable surface. Contact support for internal issues.

9. Specifikacijos

Dimensions of the Wayne CDU980E sump pump: 10.5 inches L x 9 inches W x 11 inches H.

Figure 5: Wayne CDU980E Product Dimensions

AtributasVertė
Prekės ženklasVeinas
Modelio numerisCDU980E (58321-WYN3)
Arklio jėgos0.75 AG
Maksimalus srautas5490 GPH (92 galonų per minutę)
Maksimalus kėlimo aukštis32 pėdų
ttage120 voltų
Maitinimo šaltinisSu laidu elektra
MedžiagaCast Iron and Stainless Steel
Gaminio matmenys10.5 colio ilgio x 9 colių pločio x 11 colio aukščio
Prekės svoris12 svaro
Ypatingos savybėsIntegrated Vertical Float Switch, Easy to Install
Performance chart for Wayne CDU980E sump pump showing GPH at various discharge heights.

Figure 6: Performance Data for CDU980E

10. Garantija ir palaikymas

The Wayne CDU980E Submersible Sump Pump comes with a 5 metų gamintojo garantija. For warranty claims, technical assistance, or replacement parts, please contact Wayne Water Systems customer support. Refer to the contact information provided in your product packaging or visit the official Wayne websvetainę.

Gamintojas: Wayne vandens sistemos

Susiję dokumentai - CDU980E

Preview Wayne Submersible Sump Pumps: Installation, Operation, and Maintenance Manual
Comprehensive installation manual for Wayne submersible sump pumps, covering operation, safety, troubleshooting, and limited warranty information. Includes specifications and performance data for various models.
Preview Wayne Submersible Sump Pumps: Installation, Operation, and Parts Manual
Comprehensive installation, operation, troubleshooting, and warranty guide for Wayne Submersible Sump Pumps, including specifications, performance data, and maintenance instructions.
Preview Wayne Submersible Sump Pumps: Installation and Maintenance Manual
Comprehensive guide for Wayne submersible sump pumps, covering installation, operation, troubleshooting, and maintenance. Includes specifications, diagrams, and warranty information for various models.
Preview Wayne Submersible Sump System Installation Guide and Warranty
Comprehensive installation guide and warranty information for Wayne Submersible Sump Systems, including primary and backup pump operation, unpacking, and product specifications.
Preview Wayne Submersible Sump Pump Operating Instructions and Parts Manual
This manual provides operating instructions, troubleshooting guidance, and parts lists for Wayne submersible sump pumps, including models FLS790, FLS800, SPF33, SPF50, SSCDU800, SSPF50, CDU790, CDU790HH, CDU800, and CDU980. It covers installation, operation, maintenance, safety precautions, and warranty information.
Preview Wayne Submersible Sump Pump Operating Instructions and Parts Manual
Comprehensive guide for Wayne submersible sump pumps (FLS790, FLS800, SPF33, SPF50, SSCDU800, SSPF50, CDU790, CDU790HH, CDU800, CDU980), covering operation, installation, maintenance, troubleshooting, and parts. Includes safety warnings and limited warranty information.