1. Įvadas
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Atlantic Water Gardens Tidal Wave L-310 Pump. The Tidal Wave L-310 is a low-head, high-volume axial flow pump designed for water garden and pond applications, offering a capacity of 13500 GPH. Please read all instructions carefully before installation and use to ensure proper function and longevity of the product.
2. Svarbios saugos instrukcijos
ĮSPĖJIMAS: To avoid serious injury, always disconnect power to the pump before performing any maintenance or installation procedures.
- Ensure the pump is connected to a Ground Fault Circuit Interrupter (GFCI) protected outlet.
- Do not operate the pump if the power cord is damaged. Contact a qualified electrician for repair or replacement.
- Never run the pump dry. Ensure it is fully submerged in water during operation to prevent overheating and damage.
- Do not lift or carry the pump by its power cord. Use the designated handle or body of the pump.
- Veikiant siurbliui ir vandens funkcionavimui, laikykite vaikus ir naminius gyvūnus atokiau nuo jo.
- This pump is designed for water garden use only. Do not use with flammable liquids or in swimming pools.
3. Pakuotės turinys
Atidarę pakuotę, patikrinkite, ar yra visi komponentai ir ar jie nepažeisti:
- Atlantic Water Gardens Tidal Wave L-310 Pump Unit
- Maitinimo laidas
- Instrukcijų vadovas

Image 1: Atlantic Water Gardens Tidal Wave L-310 Pump. This image shows the main pump unit, typically black or dark gray, with a robust housing and a power cord extending from it. The pump is designed for submersible use in water features.
4. Diegimas ir sąranka
4.1. Įdėjimas
Place the pump on a stable, level surface within your pond or water feature. Ensure it is fully submerged and positioned to draw water effectively without pulling in excessive debris from the bottom. Avoid placing the pump directly in heavy sludge or loose gravel.
4.2. Santechnikos prijungimas
Connect the appropriate plumbing (e.g., flexible tubing or PVC pipe) to the pump's discharge outlet. Ensure all connections are secure and watertight to prevent leaks and maintain optimal flow. Refer to your specific plumbing requirements for proper sizing and sealing.
4.3. Elektrinis sujungimas
Route the power cord to a GFCI-protected outdoor electrical outlet. Ensure the cord is protected from damage and is not pinched or strained. Do not use extension cords unless absolutely necessary and ensure they are rated for outdoor use and properly grounded.
5. Operacija
Once the pump is properly installed and submerged, plug the power cord into the GFCI-protected outlet. The pump should start immediately, circulating water. Monitor the initial operation to ensure proper flow and check for any unusual noises or vibrations. The Tidal Wave L-310 is designed for continuous operation.
6. Priežiūra
6.1. Reguliarus valymas
Periodically inspect the pump intake for debris accumulation. Disconnect power before removing the pump from the water. Clean the pump housing and impeller area to remove any leaves, algae, or other obstructions that may reduce flow or strain the motor. Use a soft brush and clean water.
6.2. Pasiruošimas žiemai
In regions with freezing temperatures, remove the pump from the pond before the first hard freeze. Clean the pump thoroughly and store it in a frost-free location, submerged in a bucket of water to keep seals lubricated, or follow manufacturer recommendations for dry storage.
7. Problemų sprendimas
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| Siurblys neįsijungia | No power; GFCI tripped; Impeller jammed | Check power connection; Reset GFCI; Disconnect power and clear impeller |
| Sumažintas vandens srautas | Clogged intake/impeller; Kinked hose; Low water level | Disconnect power and clean pump; Straighten hose; Add water to pond |
| Siurblys skleidžia neįprastą triukšmą | Debris in impeller; Pump running dry; Worn bearings | Disconnect power and clear debris; Ensure full submersion; Contact support if noise persists |
| GFCI trips repeatedly | Faulty wiring; Water in electrical connections; Damaged pump motor | Inspect wiring; Ensure dry connections; Discontinue use and contact support |
8. Specifikacijos
| Funkcija | Detalė |
|---|---|
| Modelis | L-310 |
| Talpa | 13500 GPH |
| Maksimalus kėlimo aukštis | 28 pėdų |
| ttage | 115 voltų |
| Medžiaga | Ketaus, Nerūdijantis plienas |
| Gaminio matmenys (I x P x A) | 19.25" x 9" x 19.25" |
| Prekės svoris | 95 svaro |
| Maitinimo šaltinis | Su laidu elektra |
| UPC | 727429003060 |
9. Garantija ir palaikymas
9.1. Gamintojo garantija
The Atlantic Water Gardens Tidal Wave L-310 Pump is covered by a 2 metų gamintojo garantija nuo įsigijimo datos. Ši garantija taikoma medžiagų ir gamybos defektams įprasto naudojimo sąlygomis. Išsaugokite pirkimo įrodymą, jei norėtumėte pateikti pretenzijas dėl garantijos.
9.2. Pagalba klientams
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Atlantic Water Gardens customer support. Refer to the official Atlantic Water Gardens webDabartinę kontaktinę informaciją rasite svetainėje arba produkto pakuotėje.