This manual provides detailed instructions for the installation, operation, and maintenance of your ELKAY 400A Columbus Pneumatic Timer. This device is designed to automatically switch off lighting after a user-defined period, offering a practical solution for energy management.
Svarbi saugos informacija
WARNING: Risk of electric shock. Installation should only be performed by a qualified electrician or competent person in accordance with national wiring regulations.
- Always disconnect power at the main circuit breaker before installing or servicing the timer.
- Įsitikinkite, kad visos laidų jungtys yra tvirtos ir tinkamai izoliuotos.
- Do not exceed the maximum load ratings specified for this device.
- Šis gaminys skirtas naudoti tik patalpose.
- Laikyti vaikams nepasiekiamoje vietoje.
Produktas baigtasview
The ELKAY 400A Columbus Pneumatic Timer is a single-contact, push-button operated timer. It is designed to replace standard single-gang wall switches and does not require a neutral connection. The timer provides an adjustable delay period, automatically turning off connected lighting after the set time has elapsed.

1 pav.: priekis view of the ELKAY 400A Columbus Pneumatic Timer. Shows the white ABS casing and the central push-button mechanism.
Pagrindinės funkcijos:
- Automatinis išsijungimas: Turns off lighting after a set time.
- Reguliuojamas delsos laikas: Configurable from approximately 5 seconds to 5 minutes.
- Lengvas montavimas: Replaces existing single-gang wall switches.
- Neutralios medžiagos nereikia: Simplifies wiring.
- Suderinamumas: Suitable for fluorescent (up to 6 fittings) and incandescent lighting.
- Patvari konstrukcija: Made from Acrylonitrile Butadiene Styrene (ABS).
Montavimo instrukcijos
- Maitinimo atjungimas: Before beginning installation, ensure the electrical supply to the circuit is completely disconnected at the consumer unit/fuse box. Verify with a suitable voltage testeris.
- Pašalinti esamą jungiklį: Carefully remove the existing wall switch from its mounting box. Note the wiring connections.
- Laidai:
- Connect the incoming live wire to the terminal marked 'L' or 'IN' on the ELKAY 400A timer.
- Connect the switched live wire (going to the light fitting) to the terminal marked 'SW' or 'OUT' on the ELKAY 400A timer.
- Note: This timer does not require a neutral connection.
- Laiko delsos reguliavimas:
The time delay is adjusted via a small screw located on the rear of the timer mechanism. Use a small screwdriver to turn this screw. Turning clockwise typically increases the time, and counter-clockwise decreases it. The timing range is approximately 5 seconds to 5 minutes. Adjust this setting before fully mounting the timer.
Note: Timings are approximate and may require fine-tuning after initial power-up.
- Montavimas: Carefully place the wired timer into the wall mounting box, ensuring no wires are pinched. Secure the timer to the box using the provided screws. Attach the faceplate.
- Maitinimo prijungimas iš naujo: Restore power to the circuit at the consumer unit/fuse box.
- Testavimas: Press the timer button to activate. Observe the connected lighting and verify that it switches off after the set delay. Adjust the time delay screw further if necessary (repeat steps 1, 4, 6, 7).
For optimal performance, ensure the mounting surface is flat and does not exert undue pressure on the timer mechanism, which could affect timing accuracy.
Naudojimo instrukcijos
To operate the ELKAY 400A Columbus Pneumatic Timer, simply press the central button. This action will switch on the connected lighting and simultaneously activate the internal pneumatic delay mechanism. The lighting will remain on for the pre-set duration (between 5 seconds and 5 minutes) and then automatically switch off.
- A single press activates the timer.
- The timer cannot be manually turned off before the delay period expires.
- Pressing the button again during an active cycle will restart the timer, extending the light-on period.
Priežiūra
The ELKAY 400A Pneumatic Timer requires minimal maintenance. To ensure longevity and proper function:
- Valymas: Wipe the surface with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure power is off before cleaning.
- Patikra: Reguliariai tikrinkite, ar nėra pažeidimų ar atsilaisvinusių jungčių. Jei aptinkama problemų, atjunkite maitinimą ir kreipkitės į kvalifikuotą elektriką.
- Nėra naudotojo aptarnaujamų dalių: Do not attempt to open or repair the internal mechanism of the timer. This will void any warranty and could lead to electric shock.
Trikčių šalinimas
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| Timer does not activate lights. |
|
|
| Lights do not turn off, or turn off too quickly/slowly. |
|
|
| Inconsistent timing. |
|
|
Gaminio specifikacijos
- Modelis: 400A
- Prekinis ženklas: Elkay
- Medžiaga: Akrilnitrilo butadieno stirenas (ABS)
- Spalva: Baltas
- Gaminio matmenys (G x P x A): 2.17 colio x 3.35 colio x 3.35 colio (apytiksliai 55 mm x 85 mm x 85 mm)
- Prekės svoris: 3.87 uncijos (apie 110 g)
- Laiko delsos diapazonas: Approximately 5 seconds to 5 minutes (adjustable)
- Jungiklio tipas: Single Contact, Pneumatic
- Neutral Requirement: Nereikia neutralaus
- Suderinamumas su apšvietimu:
- Kaitrinis apšvietimas
- Fluorescent lighting (maximum 6 fittings)
- Sertifikatai: CE, IEC 60669-2-1:2002, RoHS compliant
- Įtraukti komponentai: 1 x Columbus Pneumatic Timer - Single Contact - 400A
Garantija ir klientų aptarnavimas
For warranty information or technical assistance, please contact Elkay customer support. Keep your purchase receipt as proof of purchase.
Elkay Customer Support: Please refer to the official Elkay webKontaktinę informaciją rasite svetainėje arba produkto pakuotėje.