Eaton CHFCAF120

Eaton CHFCAF120 Single Pole AFCI Circuit Breaker

Instrukcijų vadovas

Įvadas

This manual provides essential information for the safe installation, operation, and maintenance of the Eaton CHFCAF120 Single Pole Arc Fault Circuit Interrupter (AFCI) Circuit Breaker. Please read all instructions carefully before beginning any work. Proper understanding and adherence to these guidelines are crucial for safe and effective use of this electrical device.

Saugos informacija

ĮSPĖJIMAS: Risk of electric shock or electrocution. Installation and servicing of this circuit breaker must be performed by a qualified electrician. Always turn off power at the main service panel before working on electrical circuits. Failure to do so can result in serious injury or death.

ATSARGIAI: This device protects against arc faults. It is not a substitute for Ground Fault Circuit Interrupters (GFCIs) where required by electrical codes. Ensure all local and national electrical codes are followed during installation.

Produkto savybės

The Eaton CHFCAF120 AFCI Circuit Breaker is designed to provide enhanced protection against electrical fires caused by arc faults. Key features include:

Specifikacijos

Prekės ženklasEaton
ModelisCHFCAF120
Dabartinis reitingas20 Amps
ttage120 voltų
Grandinės pertraukiklio tipasAFCI (Arc Fault Circuit Interrupter)
Lenkų skaičius1
Montavimo tipasĮkišamas laikiklis
Gaminio matmenys1.3 x 3.5 x 6 colio
Prekės svoris0.8 uncijos

Montavimas

SVARBU: Ensure all power to the electrical panel is OFF before proceeding with installation. Use appropriate personal protective equipment, including safety glasses and insulated gloves. If you are not a qualified electrician, do not attempt installation.

Diegimo žingsniai:

  1. Maitinimo atjungimas: Locate the main service panel and turn off the main circuit breaker to de-energize the entire panel. Verify power is off using a non-contact voltage tester on all circuits you intend to work on.
  2. Prieiga prie skydelio: Carefully remove the cover of the electrical panel, following manufacturer guidelines.
  3. Jungiklio išdėstymas: Identify an available slot in the Eaton Type CH load center. The CHFCAF120 is a single-pole breaker and requires one slot.
  4. Laido jungtis: Connect the circuit's hot wire (typically black or red) to the terminal on the AFCI breaker labeled 'LOAD'. Tighten the screw securely to the torque specified by the panel manufacturer. Connect the neutral wire from the circuit to the neutral terminal on the AFCI breaker. Then, connect the white pigtail neutral wire from the AFCI breaker to the neutral bus bar in the panel. Refer to the wiring diagram for your specific panel for precise connections. Ensure all connections are tight and secure. For a 20 Amp breaker, use 12 gauge wire.
  5. Montavimas: Align the breaker with the bus bar and firmly push it into place until it is securely seated. Ensure the pigtail neutral is properly connected and not pinched.
  6. Skydelio dangtis: Carefully replace the electrical panel cover, ensuring no wires are pinched.
  7. Energijos atstatymas: Turn the main circuit breaker back ON.
Eaton CHFCAF120 Single Pole AFCI Circuit Breaker
Image showing the Eaton CHFCAF120 Single Pole AFCI Circuit Breaker. This breaker features a single pole design, a test button, and terminals for connecting circuit wires and a neutral pigtail. This image illustrates the general appearance of the product for identification purposes.

Operacija

The Eaton CHFCAF120 AFCI Circuit Breaker operates automatically to detect and interrupt arc faults. When an arc fault is detected, the breaker will trip, cutting off power to the affected circuit to prevent potential electrical fires.

Pertraukiklio atstatymas:

  1. Suveikusio jungiklio nustatymas: A tripped AFCI breaker will typically be in an intermediate position between ON and OFF, or fully in the OFF position.
  2. IŠJUNGTI: Firmly push the breaker handle to the full OFF position. This ensures the internal mechanism is reset.
  3. ĮJUNGTI: Tvirtai paspauskite jungiklio rankenėlę į pilną įjungimo padėtį.
  4. If the breaker immediately trips again, there may still be an arc fault or an overload condition on the circuit. Investigate and resolve the cause before attempting to reset again. Do not repeatedly reset a tripping breaker without addressing the underlying issue.

Testavimas

Regular testing of the AFCI breaker is recommended to ensure proper operation and continued protection. Test the breaker monthly.

Patikrinimo procedūra:

  1. Locate Test Button: The AFCI breaker has a 'TEST' button on its face, usually colored white or yellow.
  2. Press Test Button: With power ON to the circuit, press and hold the 'TEST' button. The breaker should immediately trip to the OFF position, cutting power to the circuit.
  3. Iš naujo nustatyti pertraukiklį: Reset the breaker by first pushing the handle to the full OFF position, then to the full ON position.
  4. If the breaker does not trip when the test button is pressed, it may be faulty and should be replaced by a qualified electrician immediately.

Priežiūra

The Eaton CHFCAF120 AFCI Circuit Breaker requires minimal maintenance. Periodically inspect the breaker for any visible damage, discoloration, or loose connections. Ensure the area around the electrical panel is clear and free from obstructions to allow for proper ventilation and access. Do not attempt to open or repair the breaker yourself.

Trikčių šalinimas

Dažnos problemos ir sprendimai:

Informacija apie garantiją

For specific warranty details, including terms, conditions, and duration, please refer to the documentation provided with your original purchase or visit the official Eaton websvetainėje. Rekomenduojama išsaugoti pirkimo įrodymą, jei prireiktų pateikti pretenziją dėl garantijos.

Pagalba klientams

For technical assistance, product inquiries, or further support, please contact Eaton customer support. Contact information, including phone numbers and online resources, can typically be found on the Eaton website or product packaging. When contacting support, please have your product model number (CHFCAF120) and any relevant purchase details available.

Susiję dokumentai - CHFCAF120

Preview „Eaton“ išleidimo angos atšakos grandinės AFCI įrengimo ir bandymo vadovas
Išsamus „Eaton“ išvadų atšakos grandinės AFCI lizdo įrengimo ir bandymo vadovas, įskaitant saugos priemones, laidų jungimo instrukcijas, bandymo procedūras, trikčių šalinimą ir garantijos informaciją.
Preview 伊顿新一代空气断路器 IZM9 系列:卓越的解决方案
了解伊顿新一代 IZM9系列空气断路器,为全球电力系统提供创新、可靠且高效的动力管理解决方案.该系列产品凭借先进的PXR 电子脱扣平台、增强的安全特性(如 ARMS 闪弧减少维护系统)以及强大的通讯能力,广泛应用于建筑、信息技术、工业机械和能源公用事业等多个领域,满足客户日益增长和多样化的需求
Preview „Eaton E-VAC HV“ vakuuminio jungiklio įrengimo ir naudojimo instrukcijos
Šiame vadove pateikiama esminė „Eaton E-VAC“ uždaros vidaus didelės įtampos sistemos įrengimo, naudojimo, priežiūros ir techninė informacija.tagVakuuminis grandinės pertraukiklis (modelis IL550-0501001E), užtikrinantis saugų ir efektyvų naudojimą pramonėje ir elektros tinkluose.
Preview „Eaton Magnum“ žemos įtampos oro grandinės pertraukiklio naudotojo vadovas (1812.900A)
Išsamus „Eaton Magnum LV-Air“ automatinio jungiklio (modelis 1812.900A) naudotojo vadovas, kuriame išsamiai aprašomas montavimas, eksploatavimas, priežiūra, trikčių šalinimas ir atnaujinamos dalys. Apima fiksuotas ir ištraukiamas konfigūracijas su elektroninėmis išjungimo sistemomis.
Preview EATON 11/25 IL019140ZU Instrukcijų lapelis: RCCB ir RCBO įrengimo vadovas
Išsamios EATON PL6, PL7, HN, PF6, PF7 ir HNC serijų liekamosios srovės jungiklių (RCCB) ir liekamosios srovės jungiklių su apsauga nuo viršsrovės (RCBO) įrengimo instrukcijos ir techninės specifikacijos, įskaitant laidų schemas ir elektros duomenis.
Preview LG ir PD3 rėminio jungiklio vaikščiojamosios sijos blokavimo įrengimo instrukcijos
Instrukcijų lapelis, kuriame išsamiai aprašomas „Eaton LG“ ir „PD3“ rėminio automatinio jungiklio su vaikščiojančia sijos blokavimo sistema montavimas, surinkimas ir reguliavimas. Įskaitant dalių sąrašą, diagramas ir saugos įspėjimus.