Rectorseal 83114

RectorSeal EZ Trap 83114 3/4 inch Condensate Trap Instruction Manual

Model: 83114 | Brand: RectorSeal

1. Produktas baigtasview

The RectorSeal EZ Trap 83114 is a 3/4 inch light-duty condensate trap designed for HVAC systems. It ensures proper condensate management and is suitable for applications where pressure or specific code requirements are a concern. This trap features durable Schedule 40 PVC fittings and a clear U-bend for easy inspection.

RectorSeal EZ Trap Overview

1 vaizdas: Baigtaview of the RectorSeal EZ Trap system, highlighting its purpose for condensate management in HVAC systems.

2. Kas yra dėžutėje

  • 3/4" EZ Trap
  • Valymo šepetys

3. Svarbios pastabos

  • Install in strict accordance with RectorSeal instructions and all applicable local plumbing, drainage, and electrical codes.
  • Insulation is required when the trap is installed in an unconditioned space where sweating may occur.

4. Taikymo sritys ir funkcijos

Programos:

This trap is designed for HVAC systems to manage condensate where pressure or proper drainage is critical, or as required by code and equipment manufacturers.

Savybės:

  • Easy maintenance and access.
  • Kompaktiškas dizainas.
  • Quality construction with durable Schedule 40 PVC fittings.
  • Transparent trap for easy inspection and cleaning.
  • Watertight red caps provide easy access for cleaning the trap and drain pan outlet.
RectorSeal EZ Trap Product Data Sheet

Image 2: Product data sheet providing detailed information on the EZ Trap, including its description, important notes, applications, and kit contents.

5. Sąranka ir diegimas

Follow these steps for proper installation of the EZ Trap:

  1. Dry Fit and Mark: Dry fit all components and mark the required angles for the U-Bend and Outlet Tee for proper alignment.
  2. Glue Components: Apply appropriate PVC glue to components (Inlet Cross, U-Bend, Outlet Tee) using the dry fit markings as a guide. Glue the assembly into the drain pan line.
  3. Prijunkite kanalizacijos liniją: Glue the main drain line into the center leg of the Outlet Tee. Ensure the drain line exits the building with at least a 5-degree downward angle for proper flow.
  4. Saugūs dangteliai: Verify that all red caps are tightly secured to prevent leaks.
  5. Attach Label: Affix the cleaning label as indicated for future maintenance reference.
Installed RectorSeal EZ Trap

3 pav.: Buvęs asmuoample of the RectorSeal EZ Trap installed in an HVAC system, showing its connection to the condensate drain line.

Video 1: Official product video demonstrating the RectorSeal 83114 2 EZ 113B Trap Kit with Brush, showcasing jo savybes ir komponentus.

6. Operacija

The EZ Trap functions passively to create a water seal in the condensate drain line, preventing air from being drawn into or pushed out of the HVAC system. The clear U-bend allows for visual confirmation of water presence and flow.

7. Priežiūra

Regular maintenance is crucial for optimal performance and to prevent blockages.

  • The clear U-bend allows for easy visual inspection of the trap for any debris or blockages.
  • The watertight red caps provide convenient access points to clean the trap and the drain pan outlet.
  • Use the included cleaning brush to clear any buildup within the trap.
RectorSeal EZ Trap with Cleaning Brush

Image 4: The RectorSeal EZ Trap kit, including the clear U-bend and the flexible cleaning brush for easy maintenance.

EZ Trap 100 Series Clear Trap Kits Diagram

Image 5: Diagram illustrating various EZ Trap configurations and highlighting features like the transparent trap and watertight caps for maintenance.

8. Problemų sprendimas

No specific troubleshooting steps are provided in the product information. If you encounter issues with your EZ Trap, ensure proper installation, check for blockages, and verify that the drain line has adequate slope. Consult a qualified HVAC technician if problems persist.

9. Specifikacijos

SpecifikacijaDetalė
Modelio numeris83114
Prekės skersmuo0.75 colių
MedžiagaPlastic (Schedule 40 PVC fittings)
SpalvaRed, White, and Clear
Prekės svoris7 uncijos
Gaminio matmenys2 colio ilgio x 8.5 colio pločio
Rekomenduojamas naudojimasCondensate Management for A/C drain lines

10. Garantija

Šis produktas tiekiamas su a 3 metų ribota garantija. For more detailed information regarding the product's limited warranty, please visit the official RectorSeal websvetainę.

11. Pagalba ir kontaktinė informacija

Gamintojas:

„RectorSeal“, LLC
2601 Spenwick Drive
Hiustonas, TX 77055, JAV
Telefonas: 800-231-3345
Faksas: 800-441-0051
Websvetainė: rectorseal.com

Kanados adresas:
3255 Wyandotte St. East
Windsor, ON N8Y 1E9, Canada
Telefonas: 519-966-4901

Susiję dokumentai - 83114

Preview „RectorSeal AquaGuard AG-3180E“ montavimo instrukcijos ir garantija
Išsamus „RectorSeal AquaGuard AG-3180E“ – apsauginio jungiklio, skirto užkirsti kelią ŠVOK sistemos perpildymui, išjungiant įrenginį, kai susikaupia kondensatas, – įrengimo vadovas ir garantijos informacija. Apima saugos įspėjimus, laidų schemas ir garantijos sąlygas.
Preview „RectorSeal AQUAGUARD® 4200E“ vandens jutiklio ir išleidimo angos montavimo vadovas
Išsamios „RectorSeal AQUAGUARD® 4200E“ vandens jutiklio ir išleidimo angos montavimo instrukcijos, įskaitant laidų schemas ir išleidimo padėklo montavimo informaciją, skirtos „Titan“, „Goliath“ ir „Goliath“ krosnių modeliams.
Preview „RectorSeal AquaGuard AG-1100+“ magnetinio plūdinio jungiklio montavimo vadovas
Išsamios „RectorSeal AquaGuard AG-1100+“ magnetinio plūdinio jungiklio, skirto apsaugoti ŠVOK sistemą nuo kondensato perpildymo, įrengimo ir laidų sujungimo instrukcijos. Apima saugos įspėjimus ir diagramas.
Preview „RectorSeal AquaGuard AG-1200+“ montavimo instrukcijos
Išsamios „RectorSeal AquaGuard AG-1200+“ magnetinio plūdinio jungiklio montavimo instrukcijos, įskaitant saugos priemones, montavimo ir laidų schemas įprastinėms ir bendraujančioms ŠVOK sistemoms.
Preview „RectorSeal AG-9100 AquaGuard“ nuotolinio signalizavimo įrengimo ir garantijos vadovas
Išsamios „RectorSeal AG-9100 AquaGuard“ nuotolinio pavojaus signalizavimo sistemos įrengimo instrukcijos, laidų schemos, saugos gairės ir ribotos garantijos informacija. Sužinokite, kaip tinkamai sumontuoti, prijungti ir išbandyti AG-9100 signalizaciją.
Preview „RectorSeal AquaGuard AG-1200+“ įrengimo ir laidų sujungimo vadovas
Išsamios „RectorSeal AquaGuard AG-1200+“ magnetinio plūdinio jungiklio įrengimo ir laidų sujungimo instrukcijos, kuriose išsamiai aprašomas įprastų ir bendraujančių ŠVOK sistemų įrengimas, įskaitant saugos įspėjimus ir bandymo procedūras.