1. Įvadas
The Seco-Larm Enforcer EAP-5D5Q power supply is specifically designed for access control systems, providing centralized power for electronic locks and accessories. This unit integrates essential power sources into one heavy-duty, easy-to-install enclosure, replacing multiple individual power sources. It features robust fault response, supervision relays, and a built-in backup battery charger for enhanced system reliability.
2. Saugos priemonės ir svarbios pastabos
- Batteries not included: Backup batteries must be purchased separately.
- Naudoti tik patalpose: The Enforcer Power Supply is not waterproof or weatherproof. It must be mounted indoors where it will not be exposed to rain or other moisture.
- Kvalifikuotas personalas: Montavimą turi atlikti kvalifikuotas personalas.
- Kodo laikymasis: All installation procedures should conform to local and all other applicable codes.
- Overload/Short-circuit Protection: The board is designed with overload and short-circuit protection, including automatic shutdown and an LED overload indicator.
- AC Input Fuse: Over-current fuse-protected AC input (3.15 Amps glass fuse).
3. Produkto ypatybės
- Power supply for an access control system's electronic locks and accessories.
- Heavy-duty steel case protects the power connections.
- Ventilation holes prevent heat build-up.
- Built-in backup battery charger (backup battery is optional).
- Automatically switches to backup battery if AC power fails.
- Individual AC input and DC output LED status indicators.
- AC power failure supervision relay.
- Battery failure supervision relay.
- Selectable 2.2KΩ End-of-Line (EOL) resistor for AC failure and battery failure supervision relays via DIP switch.
- Selectable delay timer (5 sec., 5 min., 5 hours) for AC failure supervision relay via DIP switch.
- Field selectable for 12VDC or 24VDC output.
- Veikimo ttage input 110~240 VAC.
- Reguliuojamas tūristage range (11~15 VDC, 23~26 VDC) to compensate for voltage lašas.
4. Sąranka ir diegimas
The EAP-5D5Q power supply is designed for easy installation within its heavy-duty steel enclosure. Ensure all installations are performed by qualified personnel and adhere to local electrical codes.
- Montavimas: Select an indoor location that is dry and protected from moisture. Securely mount the enclosure to a wall or suitable surface.
- Prieiga: The removable steel cover allows for easy access to the internal components for wiring and configuration.
- Maitinimo įvestis: Connect the 110~240 VAC power input to the designated terminals. The unit includes a 6-foot power cord.
- DC Output Configuration: The unit offers 5 outputs. Select the desired output voltage (12VDC or 24VDC) via the internal DIP switch. Adjust the voltage range (11~15 VDC for 12VDC setting, 23~26 VDC for 24VDC setting) using the VR switch to compensate for voltage lašas.
- Atsarginės baterijos jungtis: If using backup batteries (not included), connect them using the provided battery leads. The enclosure has enough room for two 7AH batteries.
- Supervision Relays: Configure the AC failure and battery failure supervision relays as needed. Select the 2.2KΩ End-of-Line (EOL) resistor via DIP switch if required. Set the AC-Fail relay delay timer (5 sec, 5 min, or 5 hr) via DIP switch.
- Access Control Device Connections: Connect your electronic locks and other access control accessories to the appropriate DC output terminals.

1 pav. Vidinis view of the EAP-5D5Q power supply. The image displays the main power circuit board and the 5-output distribution board connected by wires, all housed within the open white metal enclosure. A wiring diagram and instructions are visible on the inside of the enclosure door.
5. Naudojimo instrukcijos
Once properly installed and configured, the EAP-5D5Q operates automatically to provide stable power to your access control system.
- Maitinimas: After connecting the AC input, the unit will power on.
- LED indikatoriai:
- Žalias šviesos diodas: Indicates AC input status.
- Raudonas šviesos diodas: Indicates DC output status.
- Mirksi raudonas šviesos diodas: Signals an output overload or short-circuit condition.
- Backup Battery Operation: In the event of an AC power failure, the unit will automatically switch to the connected backup battery (if installed) to maintain continuous power to the access control system.
- Fault Recovery: The system features auto-recovery; once an output short or overload condition is removed.
6. Priežiūra
The Seco-Larm Enforcer Power Supply is designed for reliable, low-maintenance operation. Regular checks can help ensure optimal performance.
- Vėdinimas: Ensure the ventilation holes on the enclosure are not obstructed to prevent heat build-up.
- Aplinkos sąlygos: Verify that the unit remains in a dry, indoor environment, free from moisture and extreme temperatures.
- Baterijos patikrinimas (jei taikoma): If backup batteries are installed, periodically check their condition and replace them according to the manufacturer's recommendations to ensure reliable backup power.
- Jungtys: Reguliariai tikrinkite visas laidų jungtis, ar nėra sandarumo ir korozijos požymių.
7. Problemų sprendimas
This section provides guidance for common issues you might encounter with your EAP-5D5Q power supply.
- Nėra maitinimo išvesties:
- Check if the AC input Green LED is illuminated. If not, verify AC power supply and the 3.15A glass fuse.
- Check if the DC output Red LED is illuminated. If not, ensure all connections are secure.
- Mirksi raudonas šviesos diodas:
- A flashing red LED indicates an output overload or short-circuit condition.
- Immediately disconnect devices from the outputs and inspect for shorts or excessive current draw.
- The unit features auto-recovery; once the fault is cleared, the output should resume normal operation.
- No Backup Battery Operation:
- Ensure backup batteries are properly connected and charged.
- Check the battery failure supervision relay status.
- Verify battery health; old or faulty batteries may not hold a charge.
- Supervision Relay Issues:
- Verify DIP switch settings for EOL resistor and delay timer.
- Ensure proper wiring to the alarm control panel or other integrated systems.
8. Techninės specifikacijos
| Modelio numeris | EAP-5D5Q |
| Įvesties tomastage | 110 ~ 240 VAC |
| Išėjimas ttage | 12 or 24VDC (selectable via DIP switch) |
| Reguliuojamas išvesties tūristage Diapazonas | 11~15VDC (@12VDC setting), 23~26VDC (@24VDC setting) via VR switch |
| Tiekimo srovė | 5A@12VDC / 2.5A@24VDC |
| Išėjimų skaičius | 5 Išėjimai |
| AC Input Fuse Rating | 3.15A (glass fuse) |
| LED būsenos indikatoriai | AC input (Green), DC Output (Red) |
| End-of-Line Resistor (EOL) | Selectable ON (2.2K-Ohm) or OFF via DIP switch |
| AC-Fail Relay Delay Timer | Selectable @ 5sec, 5min or 5hr via DIP switch |
| Supervision Relays Contact Rating | 3A@24VDC Dry Relay Output |
| Korpuso matmenys | 12-3/16" x 12-7/16" x 3-9/16" |
| Prekės svoris | 6 svaro |
| UPC | 676544011989 |
9. Garantija ir palaikymas
The Seco-Larm Enforcer Access Control DC Power Supply (EAP-5D5Q) comes with a 1 metų garantija nuo pirkimo datos.
For technical support or warranty claims, please contact your authorized Seco-Larm dealer or visit the official Seco-Larm websvetainė kontaktinei informacijai.