1. Įvadas
This manual provides essential information for the proper installation, operation, and maintenance of the Simplex 4090-9001 IAM Supervised IDNet Module. Please read this manual thoroughly before attempting to install or operate the device. Retain this manual for future reference.
2. Saugos informacija
ĮSPĖJIMAS: Installation and servicing of this device must be performed by qualified personnel only. Failure to follow these instructions could result in property damage, serious injury, or death. Always disconnect power before servicing.
- Laikykitės visų vietinių ir nacionalinių elektros instaliacijos kodeksų ir reglamentų.
- Užtikrinkite tinkamą įžeminimą ir laidų jungtis.
- Nenaudokite prietaiso, jei jis atrodo pažeistas.
- Saugokite nuo drėgmės ir ekstremalių temperatūrų.
3. Produktas baigtasview
The Simplex 4090-9001 is an Individual Addressable Module (IAM) designed for use within a supervised IDNet system. It is housed in a durable thermoplastic casing, providing protection for its internal components. This module facilitates communication and supervision of connected devices within a fire alarm or security system.

3.1 paveikslas: Line drawing of the Simplex 4090-9001 IAM Supervised IDNet Module. This image shows the front view of the module with its label, indicating the model number and "SUPERVISED IAM" text.

3.2 paveikslas: The Simplex 4090-9001 module shown within its clear plastic packaging. The packaging includes a label with "PID: 4090-9001", "DESCRIPTION: IAM SUPERVISED IDNET", and "PART NUMBER: 0617952". Small resistors are also visible in the package.
4. Sąranka ir diegimas
The Simplex 4090-9001 module is designed for screw mount installation. Detailed installation instructions are provided in the separate document "INST. INSTR. 574-331", which typically accompanies the product. Always refer to this document for specific wiring diagrams and mounting procedures.
4.1. Patikrinimai prieš montavimą
- Verify that the module is the correct model (4090-9001) for your system.
- Inspect the module for any signs of physical damage.
- Ensure all necessary tools and additional components (e.g., screws, wiring) are available.
4.2. Montavimas
The module features a screw mount design. Select a suitable, secure location for mounting, ensuring it is free from excessive vibration, moisture, and extreme temperatures. Use appropriate fasteners for the mounting surface.
4.3. Laidai
The module utilizes screw-type connectors for wiring. Refer to the "INST. INSTR. 574-331" document for detailed wiring diagrams specific to your system configuration. Ensure all connections are secure and comply with applicable electrical codes. The module operates at 40 Volts.
5. Operacija
Once properly installed and connected to a compatible Simplex IDNet control panel, the 4090-9001 module functions as an interface for supervising and monitoring various devices. It communicates the status of these devices back to the control panel, allowing for centralized monitoring and response in a fire safety or security system. The module's operation is largely automatic once configured within the IDNet system.
6. Priežiūra
Regular maintenance is crucial to ensure the continued reliable operation of the Simplex 4090-9001 module and the overall fire safety system. It is recommended that a qualified technician perform periodic inspections and tests.
- Vizuali apžiūra: Periodically check the module and its wiring for any signs of damage, corrosion, or loose connections.
- Sistemos testavimas: Follow the testing procedures outlined in your fire alarm system's documentation to ensure the module is communicating correctly with the control panel.
- Valymas: If necessary, gently clean the exterior of the thermoplastic housing with a dry, soft cloth. Do not use abrasive cleaners or solvents.
7. Problemų sprendimas
If the Simplex 4090-9001 module is not functioning as expected, consider the following basic troubleshooting steps. For complex issues, contact qualified service personnel.
- Nėra ryšio:
- Verify all wiring connections are secure and correct according to "INST. INSTR. 574-331".
- Check power supply to the IDNet system.
- Ensure the module's address is correctly configured in the control panel.
- Gedimo indikacija:
- Consult your IDNet control panel's manual for specific fault codes and their meanings.
- Inspect the connected device(s) for faults.
- Fizinė žala: If the module shows signs of physical damage, it should be replaced by a qualified technician.
8. Specifikacijos
| Funkcija | Detalė |
|---|---|
| Modelio numeris | 4090-9001 |
| Prekės ženklas | Paprastas |
| Aprašymas | IAM Supervised IDNet Module |
| Būsto medžiaga | Termoplastinis (plastikas) |
| Spalva | JUODAS |
| Gaminio matmenys | 8 x 8 x 4 colio |
| Prekės svoris | 0.01 uncijos |
| ttage | 40 voltų |
| Jungties tipas | Varžtas |
| Montavimo tipas | Sraigtinis kalnas |
| UPC | 683194549410 |
9. Garantija ir palaikymas
Specific warranty information for the Simplex 4090-9001 module is typically provided at the point of purchase or can be obtained directly from Simplex or an authorized distributor. For technical support, service, or warranty claims, please contact your Simplex supplier or an authorized service center. Always provide the model number (4090-9001) and any relevant serial numbers when seeking support.
For further assistance, you may visit the official Simplex website or consult the documentation provided with your complete fire alarm system.