1. Įvadas
This manual provides essential instructions for the installation, operation, and maintenance of the Cisco UCS C240 M3 High-Density Rack-Mount Server. The Cisco UCS C240 M3 is a 2-socket, 2U rack server designed for a broad range of workloads, offering high performance and expandability. Please read this manual thoroughly before proceeding with any operations to ensure proper handling and to prevent damage to the equipment or injury to personnel.
2. Saugos informacija
Observe the following safety precautions to minimize the risk of injury and to prevent damage to the server:
- Always disconnect all power cords from the server before performing any maintenance or installation procedures.
- Ensure proper grounding of the server and the rack.
- Do not operate the server with covers removed unless specifically instructed to do so for maintenance.
- Use appropriate lifting techniques when installing or removing the server from a rack due to its weight (approximately 54.7 pounds).
- Užtikrinkite tinkamą vėdinimą aplink serverį, kad jis neperkaistų.
- Montavimą ir techninę priežiūrą turėtų atlikti tik kvalifikuoti darbuotojai.
3. Pakuotės turinys
Verify that all components are present and undamaged upon unpacking. The standard package for the Cisco UCS C240 M3 server typically includes:
- Cisco UCS C240 M3 Rack Server unit
- Rack mounting rail kit
- Power cords (region-specific)
- Documentation (Quick Start Guide, Safety and Compliance Information)
- Optional components such as hard drives, memory modules, and expansion cards, if ordered.
If any items are missing or damaged, contact your Cisco representative or reseller immediately.
4. Fizinis viršusview
This section provides a visual guide to the external components of the Cisco UCS C240 M3 server.
4.1 Priekinis skydelis

4.1 paveikslas: Priekyje view of the Cisco UCS C240 M3 server. This image displays the front panel of the server, featuring 24 small form factor (SFF) hot-swappable drive bays, status LEDs, and control buttons on the left and right ears.
The front panel provides access to the hot-swappable drive bays, system status indicators, and control buttons. The C240 M3 supports up to 24 SFF 2.5-inch drives.
4.2 Galinis skydelis

4.2 paveikslas: Galinis view of the Cisco UCS C240 M3 server. This image illustrates the rear panel, including redundant hot-swappable power supplies, multiple Gigabit Ethernet ports, USB ports, a VGA port, and PCIe expansion slots.
The rear panel houses the power supply units, network interfaces, and various I/O ports. It typically includes:
- Redundant hot-swappable power supply units (e.g., 1200W AC).
- Gigabit Ethernet ports for network connectivity.
- USB ports for peripheral connections.
- VGA port for console display.
- Serial port (DB-9).
- PCIe expansion slots for additional adapters.
4.3 Viršus/Šonas View

4.3 paveikslas: Kampuotas viršutinis priekis view of the Cisco UCS C240 M3 server. This image provides a perspective of the server's chassis, highlighting its 2U rack-mountable form factor and overall design.
Tai view illustrates the overall 2U rack-mountable form factor of the server, designed for high-density environments.
5. Sąranka
Follow these steps to properly set up your Cisco UCS C240 M3 server.
5.1 Stovo montavimas
- Paruoškite stelažą: Ensure the rack is stable and has adequate space for a 2U server.
- Įdiekite bėgių rinkinį: Attach the provided rail kit to the rack posts according to the instructions included with the rail kit.
- Serverio prijungimas: Carefully slide the server onto the installed rails until it clicks into place. Secure the server to the rack using the provided screws.
5.2 Išorinių įrenginių prijungimas
- Galia: Connect the power cords from the server's power supply units to separate, grounded power outlets or a power distribution unit (PDU).
- Tinklas: Connect Ethernet cables from the server's network ports to your network switch.
- Console (Optional): For initial setup or direct access, connect a monitor to the VGA port and a keyboard/mouse to the USB ports on the rear panel.
5.3 Pradinis įjungimas
- Įsitikinkite, kad visos jungtys yra saugios.
- Paspauskite maitinimo mygtuką priekiniame skydelyje.
- Stebėkite sistemos būsenos šviesos diodus, kad įsitikintumėte, jog sistema veikia normaliai.
- Access the Cisco Integrated Management Controller (IMC) via a web browser using the server's management IP address for further configuration. Refer to the Cisco UCS C-Series Servers Integrated Management Controller GUI Configuration Guide for detailed instructions.
6. Serverio valdymas
This section covers basic operational procedures for the Cisco UCS C240 M3 server.
6.1 Įjungimo / išjungimo procedūros
- Maitinimas: Press the power button on the front panel. The system will initiate its boot sequence.
- Įprastas išjungimas: From the operating system, perform a graceful shutdown. Once the OS has shut down, the server will power off automatically.
- Priverstinis išjungimas: In an emergency, press and hold the power button for more than 4 seconds. This should only be used as a last resort to prevent data corruption.
6.2 Accessing Cisco IMC
The Cisco Integrated Management Controller (IMC) provides a web-based interface for server management. To access it:
- Ensure the server's management port is connected to the network.
- Obtain the IP address assigned to the IMC (either through DHCP or manual configuration during initial setup).
- Atidarykite a web browser and enter the IMC's IP address.
- Prisijunkite naudodami savo kredencialus.
6.3 Operacinės sistemos diegimas
Operating system installation can be performed via the Cisco IMC's KVM console, virtual media, or by booting from a physical optical drive or USB device connected to the server. Consult your chosen operating system's installation guide for specific steps.
7. Priežiūra
Reguliarus serverio aptarnavimas užtikrina optimalų našumą ir ilgaamžiškumą.
7.1 Karšto keitimo komponentai
The Cisco UCS C240 M3 features hot-swappable components, allowing replacement without powering down the server. These include:
- Kietieji diskai: Drives can be removed and inserted from the front panel. Always ensure data is backed up and the drive is properly unmounted from the operating system before removal.
- Maitinimo šaltiniai: Redundant power supplies can be replaced individually from the rear panel.
- Ventiliatoriai: Fan modules are typically hot-swappable and accessible from the top cover.
Refer to the Cisco UCS C240 M3 Server Installation and Service Guide for detailed instructions on replacing specific components.
7.2 Valymas
Periodically inspect the server for dust accumulation, especially around air vents and fan inlets/outlets. Use compressed air to gently clean dust from internal components and external surfaces. Ensure the server is powered off and disconnected from power before cleaning internal components.
7.3 Firmware atnaujinimai
Reguliariai tikrinkite „Cisco“ palaikymo tarnybą website for firmware updates for the server, RAID controller, and other components. Firmware updates can provide performance enhancements, bug fixes, and security improvements. Follow Cisco's recommended procedures for applying firmware updates.
8. Problemų sprendimas
This section provides guidance for resolving common issues.
8.1 LED indikatoriai
The server's front panel and individual components (e.g., power supplies, drives) feature LED indicators that provide status information. Consult the Cisco UCS C240 M3 Server Installation and Service Guide for a comprehensive list of LED patterns and their meanings.
- Sistemos būsenos šviesos diodas: Indicates overall server health (e.g., green for normal, amber for warning, red for critical).
- Maitinimo šaltinio šviesos diodai: Indicate power supply status (e.g., green for operational, amber for fault).
- Pavaros šviesos diodai: Indicate drive activity, status, and fault conditions.
8.2 Bendrosios problemos ir sprendimai
- Nėra galios:
- Verify power cords are securely connected to the server and power source.
- Check power supply LEDs.
- Įsitikinkite, kad maitinimo šaltinis yra aktyvus.
- Tinklo ryšio problemos:
- Patikrinkite Ethernet kabelio jungtis.
- Verify network switch port status.
- Confirm IP configuration in the operating system or IMC.
- Disko klaidos:
- Check drive LEDs for fault indications.
- Consult RAID controller utility for drive status.
- Replace faulty drives as per maintenance procedures.
8.3 Susisiekimas su palaikymo tarnyba
If you encounter issues that cannot be resolved using this guide, contact Cisco Technical Support. Have your server's serial number and a description of the problem ready.
9. Specifikacijos
Key technical specifications for the Cisco UCS C240 M3 High-Density Rack-Mount Server:
| Funkcija | Detalė |
|---|---|
| Modelio numeris | UCSC-C240-M3S-CH2 |
| Formos faktorius | Montuojamas į stelažą, 2U |
| Procesoriaus palaikymas | 2-way (Dual Processor Capable) |
| Memory (Base) | 0 MB (Configurable) |
| Saugojimo sąsaja | SATA/SAS, Hot-swap 2.5" bays |
| Grafikos valdiklis | G200e |
| Tinklo valdiklis | Gigabitinis LAN |
| Monitorius | None (External connection via VGA) |
| Gaminio matmenys | 39.7 x 24.1 x 10 colio |
| Prekės svoris | 54.7 svaro |
| Baterijos | Reikalingos gaminiui būdingos baterijos. |
| Pasiekiama pirmoji data | 1 m. lapkričio 2013 d |
10. Garantija ir palaikymas
For detailed information regarding the product warranty, service agreements, and technical support options, please refer to the official Cisco website or contact your authorized Cisco reseller. Warranty terms and conditions may vary based on region and purchase agreement.
„Cisco“ palaikymo ištekliai:
- Internetinė dokumentacija: Access comprehensive guides and manuals on the Cisco Support websvetainę.
- Technical Assistance Center (TAC): For technical issues, contact Cisco TAC.
- Programinės įrangos atsisiuntimai: Obtain the latest drivers, firmware, and software from the Cisco websvetainę.