This manual provides essential instructions for the installation, operation, and maintenance of the Cisco UCS C240 M3 High-Density Rack-Mount Server. The Cisco UCS C240 M3 is a 2-socket, 2U rack server designed for a broad range of workloads, offering high performance and expandability. Please read this manual thoroughly before proceeding with any operations to ensure proper handling and to prevent damage to the equipment or injury to personnel.

2. Saugos informacija

Observe the following safety precautions to minimize the risk of injury and to prevent damage to the server:

3. Pakuotės turinys

Verify that all components are present and undamaged upon unpacking. The standard package for the Cisco UCS C240 M3 server typically includes:

If any items are missing or damaged, contact your Cisco representative or reseller immediately.

4. Fizinis viršusview

This section provides a visual guide to the external components of the Cisco UCS C240 M3 server.

4.1 Priekinis skydelis

Priekyje view of Cisco UCS C240 M3 server with 24 small form factor drive bays

4.1 paveikslas: Priekyje view of the Cisco UCS C240 M3 server. This image displays the front panel of the server, featuring 24 small form factor (SFF) hot-swappable drive bays, status LEDs, and control buttons on the left and right ears.

The front panel provides access to the hot-swappable drive bays, system status indicators, and control buttons. The C240 M3 supports up to 24 SFF 2.5-inch drives.

4.2 Galinis skydelis

Galinis view of Cisco UCS C240 M3 server showing power supplies, network ports, and expansion slots

4.2 paveikslas: Galinis view of the Cisco UCS C240 M3 server. This image illustrates the rear panel, including redundant hot-swappable power supplies, multiple Gigabit Ethernet ports, USB ports, a VGA port, and PCIe expansion slots.

The rear panel houses the power supply units, network interfaces, and various I/O ports. It typically includes:

4.3 Viršus/Šonas View

Kampuotas viršutinis priekis view of Cisco UCS C240 M3 server

4.3 paveikslas: Kampuotas viršutinis priekis view of the Cisco UCS C240 M3 server. This image provides a perspective of the server's chassis, highlighting its 2U rack-mountable form factor and overall design.

Tai view illustrates the overall 2U rack-mountable form factor of the server, designed for high-density environments.

5. Sąranka

Follow these steps to properly set up your Cisco UCS C240 M3 server.

5.1 Stovo montavimas

  1. Paruoškite stelažą: Ensure the rack is stable and has adequate space for a 2U server.
  2. Įdiekite bėgių rinkinį: Attach the provided rail kit to the rack posts according to the instructions included with the rail kit.
  3. Serverio prijungimas: Carefully slide the server onto the installed rails until it clicks into place. Secure the server to the rack using the provided screws.

5.2 Išorinių įrenginių prijungimas

5.3 Pradinis įjungimas

  1. Įsitikinkite, kad visos jungtys yra saugios.
  2. Paspauskite maitinimo mygtuką priekiniame skydelyje.
  3. Stebėkite sistemos būsenos šviesos diodus, kad įsitikintumėte, jog sistema veikia normaliai.
  4. Access the Cisco Integrated Management Controller (IMC) via a web browser using the server's management IP address for further configuration. Refer to the Cisco UCS C-Series Servers Integrated Management Controller GUI Configuration Guide for detailed instructions.

6. Serverio valdymas

This section covers basic operational procedures for the Cisco UCS C240 M3 server.

6.1 Įjungimo / išjungimo procedūros

6.2 Accessing Cisco IMC

The Cisco Integrated Management Controller (IMC) provides a web-based interface for server management. To access it:

  1. Ensure the server's management port is connected to the network.
  2. Obtain the IP address assigned to the IMC (either through DHCP or manual configuration during initial setup).
  3. Atidarykite a web browser and enter the IMC's IP address.
  4. Prisijunkite naudodami savo kredencialus.

6.3 Operacinės sistemos diegimas

Operating system installation can be performed via the Cisco IMC's KVM console, virtual media, or by booting from a physical optical drive or USB device connected to the server. Consult your chosen operating system's installation guide for specific steps.

7. Priežiūra

Reguliarus serverio aptarnavimas užtikrina optimalų našumą ir ilgaamžiškumą.

7.1 Karšto keitimo komponentai

The Cisco UCS C240 M3 features hot-swappable components, allowing replacement without powering down the server. These include:

Refer to the Cisco UCS C240 M3 Server Installation and Service Guide for detailed instructions on replacing specific components.

7.2 Valymas

Periodically inspect the server for dust accumulation, especially around air vents and fan inlets/outlets. Use compressed air to gently clean dust from internal components and external surfaces. Ensure the server is powered off and disconnected from power before cleaning internal components.

7.3 Firmware atnaujinimai

Reguliariai tikrinkite „Cisco“ palaikymo tarnybą website for firmware updates for the server, RAID controller, and other components. Firmware updates can provide performance enhancements, bug fixes, and security improvements. Follow Cisco's recommended procedures for applying firmware updates.

8. Problemų sprendimas

This section provides guidance for resolving common issues.

8.1 LED indikatoriai

The server's front panel and individual components (e.g., power supplies, drives) feature LED indicators that provide status information. Consult the Cisco UCS C240 M3 Server Installation and Service Guide for a comprehensive list of LED patterns and their meanings.

8.2 Bendrosios problemos ir sprendimai

8.3 Susisiekimas su palaikymo tarnyba

If you encounter issues that cannot be resolved using this guide, contact Cisco Technical Support. Have your server's serial number and a description of the problem ready.

9. Specifikacijos

Key technical specifications for the Cisco UCS C240 M3 High-Density Rack-Mount Server:

FunkcijaDetalė
Modelio numerisUCSC-C240-M3S-CH2
Formos faktoriusMontuojamas į stelažą, 2U
Procesoriaus palaikymas2-way (Dual Processor Capable)
Memory (Base)0 MB (Configurable)
Saugojimo sąsajaSATA/SAS, Hot-swap 2.5" bays
Grafikos valdiklisG200e
Tinklo valdiklisGigabitinis LAN
MonitoriusNone (External connection via VGA)
Gaminio matmenys39.7 x 24.1 x 10 colio
Prekės svoris54.7 svaro
BaterijosReikalingos gaminiui būdingos baterijos.
Pasiekiama pirmoji data1 m. lapkričio 2013 d

10. Garantija ir palaikymas

For detailed information regarding the product warranty, service agreements, and technical support options, please refer to the official Cisco website or contact your authorized Cisco reseller. Warranty terms and conditions may vary based on region and purchase agreement.

„Cisco“ palaikymo ištekliai:

Susiję dokumentai - UCSC-C240-M3S-CH2

Preview „Cisco UCS C240 ​​M6 LFF Rack“ serverio specifikacijų lapas
Išsamios „Cisco UCS C240 ​​M6 LFF Rack“ serverio specifikacijos ir konfigūravimo vadovas, kuriame aprašomos jo galimybės, funkcijos, techniniai duomenys ir atsarginės dalys.
Preview „Cisco UCS C“ serijos integravimas su „Cisco UCS Manager“: išsamus vadovas
Šiame vadove pateikiama išsami informacija ir procedūros, kaip integruoti „Cisco UCS C“ serijos į stovus montuojamus serverius su „Cisco UCS Manager“, apimančios ryšio režimus, aparatinės įrangos suderinamumą, tinklo topologiją, palaikomas adapterio plokštes ir RAID / saugyklos valdiklio konfigūracijas.
Preview „Cisco UCS“ programinės įrangos atnaujinimo gairės ir būtinosios sąlygos
Išsamus vadovas, kuriame išsamiai aprašoma geriausia praktika, prielaidos ir procedūros, kaip atnaujinti programinę-aparatinę įrangą „Cisco UCS“ sistemose, įskaitant tinklo jungtis, serverius ir adapterius.
Preview Cisco UCS Rack Server Software Release Notes 4.2(2)
Comprehensive release notes for Cisco UCS Rack Server Software, version 4.2(2). Includes details on new features, hardware and software compatibility matrices, upgrade paths, security fixes, resolved and open caveats, and known behaviors for Cisco UCS C-Series servers.
Preview „Cisco UCS C220 M5 Rack“ serverio specifikacijų lapas
Išsamios „Cisco UCS C220 M5 Rack“ serverio (mažo formato disko modelio) specifikacijos ir konfigūravimo vadovas, kuriame aprašomos jo funkcijos, komponentai ir sąranka.
Preview Cisco UCS C-シリーズ ソフトウェア リリースノート 3.0(4)
Cisco UCS C-シリーズ ソフトウェア リリース 3.0(4) の公式リリースノート。Cisco UCS C-シリーズ サーバの最新機能、システム要件、既知の問題、および互換性情報について解説します。