The Greenlee CM-660 is a general-purpose AC True RMS clamp meter designed for accurate electrical measurements. This instrument is capable of measuring AC currents, DC voltages, resistance, and frequency. It incorporates a digital low-pass filter for precise readings on variable frequency drives (VFDs) and features AmpTip™ technology for enhanced accuracy on small wires carrying low currents (60 amps arba mažiau).
Key features include non-contact AC voltage detection, continuity testing, and diode testing. The meter can record average, maximum, and minimum readings, and offers two voltage detection modes: non-contact or single test lead. It is powered by two 1.5V AAA batteries and comes with test leads and a carrying case for convenience. The CM-660 has a 6000-count LCD display and a 1.18-inch jaw opening. It is UL listed, ensuring compliance with safety standards.

Figure 1.1: Greenlee CM-660 General Purpose AC Clamp Skaitiklis.
2. Saugos informacija
Always adhere to safety precautions when using electrical test equipment. Failure to do so may result in injury or damage to the meter.
- Skaitykite instrukcijas: Read and understand all instructions and safety information before operating the meter.
- Kvalifikuotas personalas: This meter should only be used by qualified personnel who are familiar with electrical hazards.
- Asmeninės apsaugos priemonės (AAP): Always wear appropriate PPE, including safety glasses and insulated gloves, when working with electrical circuits.
- ttage Ribos: Neviršykite didžiausio tūriotage ratings specified for the meter (600 VAC/DC).
- Srovės ribos: Do not exceed the maximum current ratings (600 Amps).
- Patikrinkite bandymo laidus: Before each use, inspect test leads for damage. Do not use if insulation is cracked or if the conductor is exposed.
- Nekontaktinis ttage aptikimas: Use non-contact voltage detection as a preliminary check only. Always verify with direct contact measurements.
- Baterijos keitimas: Ensure the meter is disconnected from all circuits before opening the battery compartment.
- Aplinkos sąlygos: Do not use the meter in wet conditions or in the presence of explosive gases or dust.
- Proper Function: If the meter appears to be damaged or is not operating correctly, discontinue use immediately.
3. Sąranka
3.1 Akumuliatoriaus įdėjimas
The Greenlee CM-660 requires two 1.5V AAA batteries for operation. These are typically included with the meter.
- Ensure the meter is turned OFF and disconnected from any electrical circuits.
- Suraskite baterijų skyriaus dangtelį matuoklio gale.
- Atsuktuvu atlaisvinkite varžtą, tvirtinantį akumuliatoriaus dangtelį.
- Remove the cover and insert two AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Uždėkite akumuliatoriaus dangtelį ir tvirtai priveržkite varžtą.
3.2 Pirminė apžiūra
Before first use, and periodically thereafter, perform a visual inspection of the meter and its accessories.
- Check the meter casing for any cracks, damage, or signs of wear.
- Inspect the test leads for frayed insulation, exposed wires, or damaged connectors.
- Ensure the jaw mechanism opens and closes smoothly and securely.
- Verify the display is clear and free from defects when the meter is powered on.

Figure 3.1: Included test leads and carrying case.
4. Naudojimo instrukcijos
The Greenlee CM-660 offers various measurement functions. Always select the appropriate function before making a measurement.
4.1 metro viršview

Figure 4.1: Diagram illustrating key features of the Greenlee CM-660 clamp meter, including the clamp jaw, AmpTip, non-contact AC voltage detection, AC voltage with digital filter, over-molded grip, and display.
- Clamp Žandikaulis: Used for non-contact AC current measurements.
- AmpTip™: Provides increased accuracy for low AC currents (60 amps or less) on small wires.
- Funkcinis ratukas: Selects the desired measurement mode (AC Current, DC Voltage, Resistance, Frequency, Continuity, Diode).
- Ekranas: 6000-count LCD for clear reading of measurements.
- Test Lead Inputs: Ports for connecting test leads for voltage, resistance, continuity, and diode measurements.
- Nekontaktinis AC ttage aptikimas: Integrated sensor for detecting live AC voltage be tiesioginio kontakto.
- Digital Low Pass Filter: Improves accuracy when measuring AC voltage on variable frequency drives.
4.2 Measuring AC Current (Clamp)
- Turn the function dial to the AC current (A~) position.
- Atidarykite klamp žandikaulį paspausdami svirtį.
- Apvyniokite vieną laidininką laidininkuamp žiauna. Įsitikinkite, kad žiauna visiškai uždaryta aplink laidininką.
- Nuskaitykite kintamosios srovės vertę ekrane.
- For small wires carrying 60 amps or less, the AmpTip™ feature automatically provides increased accuracy.

Figure 4.2: The CM-660 clamp meter in use, measuring current by clampaplink vieną laidininką.
4.3 DC matavimas Voltage
- Insert the red test lead into the VΩHz input and the black test lead into the COM input.
- Turn the function dial to the DC voltage (V=) padėtyje.
- Connect the red test lead to the positive side of the circuit and the black test lead to the negative side.
- Perskaitykite DC ttage reikšmė ekrane.
4.4 Atsparumo matavimas
- Prieš matuodami varžą, įsitikinkite, kad grandinė yra atjungta nuo įtampos.
- Insert the red test lead into the VΩHz input and the black test lead into the COM input.
- Turn the function dial to the Resistance (Ω) position.
- Prijunkite bandymo laidus prie matuojamo komponento arba grandinės.
- Perskaitykite pasipriešinimo vertę ekrane.
4.5 Tęstinumo testas
- Prieš atlikdami tęstinumo testą, įsitikinkite, kad grandinėje nėra įtampos.
- Insert the red test lead into the VΩHz input and the black test lead into the COM input.
- Turn the function dial to the Continuity (Buzzer symbol) position.
- Prijunkite bandymo laidus prie grandinės arba komponento.
- The meter will emit an audible tone if continuity is detected (low resistance).
4.6 Diodų bandymas
- Ensure the circuit is de-energized before performing a diode test.
- Insert the red test lead into the VΩHz input and the black test lead into the COM input.
- Turn the function dial to the Diode (Diode symbol) position.
- Prijunkite raudoną bandymo laidą prie diodo anodo, o juodą bandymo laidą – prie katodo.
- Ekrane bus rodomas garsumas pirmyntage drop. Reverse the leads; the display should show "OL" (Open Line) for a good diode.
4.7 Nekontaktinė AC ttage Aptikimas
- Turn the function dial to the NCV (Non-Contact Voltage) padėtis.
- Hold the meter with the NCV sensor near the conductor or outlet.
- Jei AC ttage is present, the meter will indicate with an audible beep and/or visual indicator.
- ĮSPĖJIMAS: This feature is for preliminary detection only. Always verify voltage presence and magnitude with direct contact measurements using test leads.
5. Priežiūra
Proper maintenance ensures the longevity and accuracy of your Greenlee CM-660 clamp metras.
5.1 Valymas
- Nuvalykite skaitiklį casing su reklamaamp skudurėliu ir švelniu plovikliu. Nenaudokite abrazyvinių valiklių ar tirpiklių.
- Ensure no moisture enters the meter's openings.
- Clean the test leads regularly, especially the probe tips, to ensure good electrical contact.
5.2 Akumuliatoriaus keitimas
Refer to Section 3.1 for battery installation instructions. Replace batteries promptly when the low battery indicator appears on the display to ensure accurate readings.
5.3 Saugykla
- Store the meter in its carrying case when not in use to protect it from dust and physical damage.
- Jei ilgesnį laiką sandėliuosite, išimkite baterijas, kad išvengtumėte jų ištekėjimo.
- Store in a cool, dry environment, away from direct sunlight and extreme temperatures.
6. Problemų sprendimas
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| Matuoklis neįsijungia. | Neišsikrovusios arba neteisingai įdėtos baterijos. | Patikrinkite baterijų poliškumą; pakeiskite baterijas. |
| Rodomas užrašas „OL“ (perkrova). | Matavimas viršija skaitiklio diapazoną. | Ensure the measurement is within the meter's specified range. |
| Netikslūs rodmenys. |
|
|
| Nėra tęstinumo pyptelėjimo. |
|
|
7. Specifikacijos
The following table outlines the key specifications for the Greenlee CM-660 General Purpose AC Clamp Skaitiklis.
| Funkcija | Specifikacija |
|---|---|
| Modelis | CM-660 |
| Matavimo tipas | AC Current, DC Voltage, Resistance, Frequency, Continuity, Diode |
| Kintamosios srovės diapazonas | Iki 600 Amps |
| DC ttage Diapazonas | Iki 600 VDC |
| AC ttage Diapazonas | Iki 600 VAC |
| Atsparumo diapazonas | Up to 60 kΩ |
| Dažnių diapazonas | 50/60 Hz (voltage/AmpTip currents), 50-400 Hz (higher currents) |
| Ekranas | 6000 skaitmenų LCD ekranas |
| Žandikaulio atidarymas | 1.18 colio (30 mm) |
| Maitinimo šaltinis | 2 x 1.5 V AAA baterijos |
| Saugos įvertinimas | UL Listed, CAT IV 300V, CAT III 600V |
| Matmenys (I x P x A) | 5.5 x 11.4 x 2.2 colių (apytiksliai) |
| Prekės svoris | 16 uncijų (1 svaras) |
| Ypatingos savybės | AmpTip™, Digital Low Pass Filter, Non-Contact AC Voltage Detection, Max/Min/Avg Recording, Data Hold, Auto Power Off |

Figure 7.1: Approximate dimensions of the CM-660 clamp meter shown in hand for scale.
8. Garantija ir palaikymas
8.1 Informacija apie garantiją
Greenlee products are manufactured to high standards and are backed by a limited warranty against defects in materials and workmanship. For specific warranty terms and conditions applicable to your CM-660 clamp meter, please refer to the warranty card included with your product or visit the official Greenlee websvetainėje. Išsaugokite pirkimo įrodymą garantiniams reikalavimams.
8.2 Pagalba klientams
For technical assistance, troubleshooting, or service inquiries, please contact Greenlee customer support. Contact information can typically be found on the Greenlee websvetainėje arba produkto pakuotėje.
Internetiniai ištekliai: For additional product information, FAQs, and support, visit the official Greenlee websvetainė: www.greenlee.com