Lantronix UD1100001-01

Lantronix UDS1100 UD1100001-01 Device Server Instruction Manual

Model: UD1100001-01

1. Įvadas

The Lantronix UDS1100 UD1100001-01 is a single-port serial to IP Ethernet device server designed to connect serial devices to an Ethernet network. This device enables remote management and access to equipment that traditionally uses serial communication (RS232, RS422, RS485) by converting serial data into IP packets. It offers a straightforward and cost-effective solution for integrating legacy serial devices into modern network infrastructures.

2. Saugos informacija

3. Pakuotės turinys

Patikrinkite, ar pakuotėje yra visi reikalingi daiktai:

4. Produkto ypatybės

5. Physical Description and Components

The Lantronix UDS1100 device server features a compact, grey enclosure with various ports and indicators for connectivity and status monitoring.

Lantronix UDS1100 Device Server, front-top view, showing serial port and status LEDs.

1 pav.: Priekinė-viršutinė dalis view of the Lantronix UDS1100 Device Server. This image displays the device's grey casing, the DB-25 serial port on the front, and status indicators for Power, 10/100 MB Link, 10/100 Activity, and Diagnostic Status on the top panel. The Lantronix logo and UDS1100 model name are also visible.

Lantronix UDS1100 Device Server, angled view, showing mounting bracket.

2 pav.: Kampinis view of the Lantronix UDS1100 Device Server. This image provides a slightly different perspective, highlighting the integrated mounting bracket on the side of the device, which facilitates wall or rail mounting. The DB-25 serial port is also visible from this angle.

Pagrindiniai komponentai:

6. Sąranka

Follow these steps to set up your Lantronix UDS1100 Device Server:

  1. Montavimas: Secure the device server in your desired location using the integrated mounting brackets. Ensure adequate ventilation.
  2. Connect Serial Device: Connect your serial device to the DB-25 serial port on the UDS1100 using an appropriate serial cable.
  3. Prisijunkite prie tinklo: Connect an Ethernet cable from your network switch or router to the RJ-45 Ethernet port on the UDS1100.
  4. Taikyti galią: Connect the provided power adapter to the device and then plug it into a suitable 110VAC power outlet. The Power LED should illuminate.
  5. Pradinė konfigūracija: Refer to the Lantronix UDS1100 User Guide (available on the Lantronix website) for detailed instructions on initial network configuration, including IP address assignment and serial port settings. This typically involves using a web browser or a dedicated utility.

7. Naudojimo instrukcijos

Once configured, the Lantronix UDS1100 operates as a transparent bridge between your serial device and the Ethernet network. Data sent from the serial device is encapsulated into IP packets and transmitted over the network, and vice-versa.

8. Priežiūra

The Lantronix UDS1100 is designed for reliable operation with minimal maintenance. However, periodic checks can ensure optimal performance:

9. Problemų sprendimas

If you encounter issues with your UDS1100, consider the following troubleshooting steps:

For more advanced troubleshooting, consult the comprehensive user manual available on the Lantronix support websvetainę.

10. Specifikacijos

FunkcijaSpecifikacija
Prekės ženklasLantronix
Modelio numerisUD1100001-01
Serijiniai prievadai1 x DB-25 (RS232/RS422/RS485)
Ethernet prievadai1 x RJ-45 (10/100 Mbps Fast Ethernet)
ProcesoriusLantronix DSTNI-EX 48 MHz
Maitinimo įvestis110VAC (US Domestic)
AtitiktisUL864
Montavimo parinktysWall Mountable, Rail Mountable
SpalvaPilka
Prekės svoris1.6 svaro
Pakuotės matmenys13.98 x 7.13 x 3.07 colio

11. Garantija ir palaikymas

Lantronix products typically come with a standard manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your product or visit the official Lantronix website. For technical support, product documentation, and firmware downloads, please visit the Lantronix support portal:

Lantronix palaikymas Websvetainę

Contact Lantronix customer service for assistance with product registration, warranty claims, or advanced technical issues.

Susiję dokumentai - UD1100001-01

Preview „MatchPort AR“ integravimo vadovas
Šiame vadove pateikiama išsami informacija apie „Lantronix MatchPort AR“ įterptinio įrenginio serverio integravimą į įvairius gaminius. Jame aptariamos aparatinės įrangos savybės, specifikacijos, kontaktų išdėstymas, nuosekliosios ir tinklo jungtys, demonstracinio rinkinio informacija ir atitikties informacija.
Preview „Lantronix UDS1100“ greito paleidimo vadovas: sąranka ir konfigūravimas
Greitai pradėkite dirbti su „Lantronix UDS1100“ nuosekliojo ryšio eterneto įrenginių serveriu. Šiame vadove aprašomas išpakavimas, prijungimas, IP adresų nustatymas, programinės įrangos diegimas, konfigūravimas ir trikčių šalinimas.
Preview „Lantronix XPort AR“ įterptinio įrenginio serverio duomenų lapas
Išsamus „Lantronix XPort AR“, programuojamo įterptinio procesoriaus modulio, skirto Ethernet tinklų kūrimui, techninis duomenų lapas. web serverio galimybes įrenginiuose. Ypatybės: RJ45 formos koeficientas, 3 nuoseklieji prievadai, didelio našumo DSTni SoC, 11 GPIO kontaktų, PoE palaikymas ir įmonės lygio saugumas.
Preview Lantronix SDSTX3110-121S-LRT Industrial Serial Device Server User Guide
This user guide provides comprehensive information on the Lantronix SDSTX3110-121S-LRT Industrial Serial Device Server, covering hardware overview, installation, management, technical specifications, and troubleshooting.
Preview Lantronix UDS100 User Guide: Serial to Ethernet Device Server
Explore the Lantronix UDS100 User Guide for detailed information on connecting serial devices (RS-232, RS-485/422) to Ethernet networks. Learn about setup, configuration, protocols, and troubleshooting for this essential device server.
Preview Lantronix SLC 8000 Advanced Console Manager User Guide
Comprehensive user guide for the Lantronix SLC 8000 Advanced Console Manager, detailing installation, configuration, features, and management of remote IT infrastructure via serial and USB console ports.