The Reznor EMC-10-AK2-HG7 Electric Cabinet Unit Heater is designed for primary or supplementary heating, or freeze protection in various environments. This 208-volt unit features a two-speed motor and a maximum heat capacity of 34,144 BTU/hr. Its robust construction includes an 18-gauge stainless steel housing, tubular heating elements with fins, and an epoxy/polyester powder paint coating for enhanced corrosion resistance. The unit can be configured for either floor or ceiling mounting, offering flexible installation options.

Vaizdas: priekis view of the Reznor EMC-10 Electric Cabinet Unit Heater, showing its white cabinet, top and bottom grilles, and the "REZNOR" logo in red.
Saugos informacija
- Prieš valydami ar aptarnaudami įrenginį, visada atjunkite maitinimą.
- Užtikrinkite tinkamą įžeminimą, kad išvengtumėte elektros smūgio.
- Do not block air intake or exhaust grilles.
- Maintain adequate clearance around the heater as specified in installation guidelines.
- Montavimą ir techninę priežiūrą turėtų atlikti tik kvalifikuoti darbuotojai.
- This unit operates at high temperatures; avoid contact with hot surfaces.
Sąranka ir diegimas
The EMC-10 unit can be installed as a floor-mounted or ceiling-mounted system. Proper installation is crucial for safe and efficient operation. Refer to the detailed installation manual provided with the product for specific mounting instructions, electrical wiring diagrams, and clearance requirements.
Elektrinis sujungimas
- The unit requires a 208V, 1 Phase electrical supply.
- Visa instaliacija turi atitikti nacionalinius ir vietinius elektros kodeksus.
- Įsitikinkite, kad maitinimo įtampa atitinka įrenginio įtampątage ir fazės reikalavimai.
- A dedicated circuit breaker is recommended for the heater.
Naudojimo instrukcijos
The EMC-10 Electric Cabinet Unit Heater is equipped with a two-speed motor for flexible heating control. Operation is typically managed via an external thermostat or control system (not included with the unit).
Pagrindinė operacija
- Ensure the unit is properly installed and connected to the power supply.
- Set the desired temperature on your external thermostat.
- The unit will activate when the ambient temperature falls below the thermostat setting.
- The two-speed motor allows for adjustment of airflow and heat distribution. Consult your control system's manual for specific fan speed selection.
- The high-temperature control with automatic reset provides an additional safety feature, shutting off the unit if overheating occurs.
Priežiūra
Regular maintenance ensures optimal performance and longevity of your Reznor EMC-10 unit. Always disconnect power before performing any maintenance.
- Kas mėnesį: Inspect air intake and exhaust grilles for obstructions. Clean any dust or debris using a soft brush or vacuum cleaner.
- Kasmet: Have a qualified technician inspect the electrical connections, heating elements, and motor for wear or damage.
- Do not use abrasive cleaners or solvents on the unit's exterior. Use a damp cloth with mild soap if cleaning is necessary.
Trikčių šalinimas
Prieš kreipdamiesi į klientų aptarnavimo tarnybą, dar kartąview šios dažniausios problemos ir sprendimai:
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| Įrenginys neįsijungia. | No power supply; tripped circuit breaker; thermostat set too low; safety control activated. | Check power connection; reset circuit breaker; adjust thermostat setting; allow unit to cool if safety control tripped. |
| Nepakankamas šilumos išsklaidymas. | Blocked grilles; incorrect fan speed; unit undersized for space. | Clear obstructions from grilles; ensure proper fan speed setting; consult a professional for sizing verification. |
| Neįprasti garsai iš įrenginio. | Loose components; motor issue; debris in fan. | Disconnect power and inspect for loose parts; contact a qualified technician for motor inspection. |
If the issue persists after attempting these solutions, please contact Reznor customer support.
Specifikacijos
- Modelis: EMC-10-AK2-HG7
- Prekinis ženklas: Reznoras
- ttage: 208 V
- Fazė: 1 fazė
- Galia: 10 kW
- Šilumos talpa: 34,144 BTU/val
- Korpuso medžiaga: 18 dydžio, nerūdijančio plieno
- Variklis: Two-speed, direct drive, variable speed fan
- Danga: Epoxy/polyester powder paint
- Saugos savybės: High-temperature control with automatic reset
- Montavimo parinktys: Floor or Ceiling mounted
- ASIN: B014XAOY3Q
- Pirmas prieinamas: 4 m. gegužės 2012 d
Informacija apie garantiją
The Reznor EMC-10 Electric Cabinet Unit Heater comes with a 1 metų dalių garantija from the date of purchase. This warranty covers defects in materials and workmanship under normal use and service. For warranty claims or detailed terms and conditions, please refer to the official warranty document included with your product or contact Reznor customer support.
Pagalba klientams
For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Reznor customer support. Have your model number (EMC-10-AK2-HG7) and purchase date ready when you call.
Contact information for Reznor can typically be found on their official websvetainėje arba ant produkto pakuotės.