FireAngel HT-630R

FireAngel HT-630 Heat Alarm

Naudotojo instrukcija

Model: HT-630R | Brand: FireAngel

1. Įvadas

The FireAngel HT-630 Heat Alarm is designed to provide early warning of fires by detecting rapid increases in temperature. Unlike smoke alarms, this heat alarm utilizes Thermistek technology to react to heat rather than smoke, making it ideal for installation in environments where smoke alarms might frequently trigger false alarms, such as kitchens, garages, and lofts.

This alarm features a sealed 10-year battery, ensuring continuous protection without the need for battery replacement throughout its operational lifespan. It is equipped with a test/silence button for easy functional checks and temporary silencing.

Pagrindinės funkcijos:

  • Thermistek heat sensing technology for rapid temperature increase detection.
  • 10-year sealed battery life, eliminating battery changes.
  • Integrated power indicator and test/silence button.
  • Suitable for kitchens, garages, and lofts where smoke alarms are not recommended.
  • Audible alarm with 85 decibels sound level.
FireAngel HT-630 Heat Alarm front view

1 paveikslas: Priekyje view of the FireAngel HT-630 Heat Alarm, showing the central test button and warning text.

2. Saugos informacija

Prieš montuodami ir naudodami atidžiai perskaitykite visas instrukcijas. Išsaugokite šį vadovą ateičiai.

  • This heat alarm is designed for domestic use only.
  • Do not paint the alarm. Paint can block the sensor and prevent proper operation.
  • Nemontuokite vietose, kuriose yra itin aukšta temperatūra ar didelė drėgmė.
  • Regularly test the alarm as described in the 'Operation' section.
  • The battery is sealed and not replaceable. Do not attempt to open the unit.
  • Upon activation, the alarm produces a loud sound. Avoid prolonged exposure to the alarm sound at close range.

3. Montavimas ir išdėstymas

Rekomenduojama vieta:

Heat alarms are specifically recommended for areas where smoke alarms are unsuitable due to potential false alarms. These areas include:

  • Virtuvės: To detect fires from cooking without reacting to cooking fumes.
  • Garažai: To detect fires from vehicles or stored flammable materials without reacting to vehicle exhaust.
  • Lofts/Attics: Where dust or temperature fluctuations might affect smoke alarms.

Install the alarm on the ceiling, centrally in the room if possible, and at least 30cm (12 inches) away from walls or light fittings. Avoid placing near air vents, fans, or areas with high airflow that could interfere with heat detection.

Diagram of recommended alarm placement in a home

2 paveikslas: Diagram illustrating recommended placement of various alarms within a home, specifically showing heat alarms in the kitchen, garage, and loft.

Diegimo žingsniai:

  1. Paruoškite tvirtinimo plokštę: Separate the mounting plate from the alarm unit by twisting the alarm counter-clockwise.
  2. Pažymėkite ir gręžkite: Hold the mounting plate against the ceiling at your desired installation point. Mark the positions for the screw holes. Drill holes and insert wall plugs if necessary.
  3. Pritvirtinkite montavimo plokštę: Secure the mounting plate to the ceiling using the provided screws. Ensure it is firmly attached.
  4. Attach Alarm Unit: Align the alarm unit with the mounting plate and twist it clockwise until it clicks securely into place. This action will activate the sealed battery.
  5. Patikrinkite žadintuvą: Press and hold the test button for a few seconds until the alarm sounds. This confirms proper installation and functionality.
Three-step installation diagram for heat alarm

3 paveikslas: Diagram showing the three-step installation process for the heat alarm: preparing the mounting plate, attaching it to the ceiling, and twisting the alarm onto the plate.

4. Operacija

Signalizacijos testavimas:

It is crucial to test your heat alarm regularly to ensure it is functioning correctly. Test the alarm weekly or at least monthly.

  • Press and hold the large 'TEST / x' button located on the front of the alarm.
  • The alarm will emit a loud, continuous sound. Release the button when the sound stops.
  • If the alarm does not sound, refer to the 'Troubleshooting' section.

Pavojaus signalai:

  • Loud, Continuous Alarm: Indicates a rapid rise in temperature has been detected, signaling a potential fire. Evacuate the premises immediately.
  • Short Chirp (every 45 seconds): Indicates a low battery warning. Since the battery is sealed, the entire unit must be replaced.
  • Short Chirp (every 30 seconds): Indicates a fault with the alarm. The unit should be replaced.
Infographic explaining Thermistek technology

4 paveikslas: Infographic explaining Thermistek technology, comparing its rapid heat detection to conventional heat alarms with diagrams of convection currents and radiant energy.

5. Priežiūra

The FireAngel HT-630 Heat Alarm requires minimal maintenance due to its sealed battery and design.

  • Reguliarus testavimas: As mentioned in the 'Operation' section, test the alarm weekly or monthly.
  • Valymas: Gently vacuum the alarm's exterior with a soft brush attachment once a month to remove dust and debris. Do not use cleaning solvents or spray chemicals directly on the alarm.
  • Baterija: The 10-year sealed battery is designed to last the lifetime of the alarm. If a low battery chirp occurs, the entire unit must be replaced.
  • Gyvenimo pabaiga: After 10 years from activation, the alarm will indicate its end-of-life. Replace the unit promptly.

6. Problemų sprendimas

  • Alarm does not sound during test:
    Ensure the alarm is correctly twisted onto its mounting plate, activating the battery. If it still doesn't sound, the unit may be faulty and requires replacement.
  • Alarm chirps every 45 seconds:
    This indicates a low battery. The sealed battery cannot be replaced. The entire alarm unit must be replaced.
  • Alarm chirps every 30 seconds:
    This indicates a fault with the alarm unit. The alarm should be replaced immediately.
  • Klaidingi aliarmai:
    While less common with heat alarms, ensure the alarm is not installed directly above heat sources (e.g., stove burners, ovens) or in areas with extreme temperature fluctuations. If false alarms persist, review placement and consider if the environment is suitable for a heat alarm.

7. Specifikacijos

FunkcijaDetalė
Modelio numerisHT-630R
Aptikimo technologijaThermistek Heat Sensing
Maitinimo šaltinisSealed 10-Year Lithium Battery
Aliarmo garso lygis85 Decibels at 3 meters
Gaminio matmenys5.31 x 5.31 x 2.36 colio
Prekės svoris6.3 uncijos (180 gramų)
MedžiagaPlastikiniai
SertifikavimasCE marked, Kitemarked (BS 5446-2:2003 KM 677057)
Naudojimo aplinkaIndoor (Kitchens, Garages, Lofts)
CE and Kitemark certification logos

5 paveikslas: Image displaying the CE mark and Kitemark certification logos, indicating compliance with European safety standards (BS 5446-2:2003 KM 677057).

8. Garantija ir palaikymas

Manufacturer's Guarantee:

The FireAngel HT-630 Heat Alarm comes with a 10-year manufacturer's guarantee, covering defects in materials and workmanship under normal use and service. This guarantee period begins from the date of purchase.

Išsaugokite pirkimo įrodymą, kad galėtumėte kreiptis dėl garantijos.

Klientų aptarnavimas:

For technical assistance, warranty claims, or further information regarding your FireAngel HT-630 Heat Alarm, please contact FireAngel customer support through their official websvetainėje arba kontaktinę informaciją, pateiktą kartu su gaminio pakuote.

Websvetainė: www.fireangel.co.uk

Susiję dokumentai - HT-630R

Preview „FireAngel ZW“ modulio įrengimo vadovas
Išsamus vadovas, skirtas „FireAngel ZW-MODULE“ belaidžio sujungimo modulio, skirto su „Z-Wave“ suderinamiems dūmų ir šilumos detektoriams, diegimui ir konfigūravimui. Apima informaciją apie sąranką, baterijų keitimą, trikčių šalinimą ir garantiją.
Preview FireAngel SM-SN-1 and HM-SN-1 Mains Powered Smoke and Heat Alarm Installation and User Guide
Comprehensive guide for installing and using FireAngel SM-SN-1 (Mains Powered Smoke Alarm) and HM-SN-1 (Mains Powered Heat Alarm). Covers system grades, positioning, hardwire and wireless interlinking, alarm testing, smart silence features, troubleshooting, maintenance, and warranty information.
Preview FireAngel FA6111, FA6115, FA6120 Smoke Alarms & FA6215 Heat Alarm User Manual
Comprehensive user manual for FireAngel FA6111, FA6115, FA6120 optical smoke alarms and FA6215 heat alarm, covering installation, maintenance, troubleshooting, features like Silence and Sleep Easy, warranty, and disposal.
Preview „FireAngel“: svarbi informacija namų gyventojams apie gaisro aptikimo ir signalizacijos sistemas
Namų savininkams skirtos gairės, kaip naudoti, prižiūrėti ir suprasti „FireAngel“ gaisro aptikimo ir signalizacijos sistemas, įskaitant veiksmus signalizacijos metu, klaidingų signalizacijų vengimą ir įprastinius patikrinimus.
Preview FireAngel W2-MODULE P-LINE Installation Guide
Comprehensive installation guide for the FireAngel W2-MODULE P-LINE wireless module, detailing setup, interlinking Wi-Safe 2 alarms, troubleshooting, and warranty information for enhanced fire safety systems.
Preview „FireAngel“ dūmų ir karščio detektorių naudotojo vadovas: FA6611, FA6615, FA6620, FA6720
Išsamus „FireAngel FA6611“, „FA6615“, „FA6620“ optinių dūmų detektorių ir FA6720 šilumos detektorių naudotojo vadovas. Apima įrengimą, priežiūrą, trikčių šalinimą, garantiją ir utilizavimą.