1. Įvadas
This user manual provides essential information for the safe and efficient operation, installation, and maintenance of your OHAUS Pioneer PA213 Precision Balance. Please read this manual thoroughly before operating the balance to ensure correct usage and to prevent damage or injury. Keep this manual for future reference.
2. Saugos informacija
Visada laikykitės šių saugos priemonių:
- Operate the balance only as described in this manual.
- Užtikrinkite maitinimo šaltinio ttage matches the requirements specified on the balance's rating label.
- Do not operate the balance in hazardous environments or with unstable power sources.
- Venkite svarstyklių veikimo esant ekstremalioms temperatūroms, drėgmei ar tiesioginiams saulės spinduliams.
- Do not attempt to open or service the balance yourself. Refer all servicing to qualified personnel.
- Laikykite svarstykles švarias, be dulkių ir šiukšlių.
3. Pakuotės turinys
Išpakuodami patikrinkite, ar visos prekės yra ir nepažeistos:
- OHAUS Pioneer PA213 Precision Balance
- Maitinimo adapteris
- Svėrimo indas
- Draft Shield (for models with 0.1mg and 1mg readability)
- Vartotojo vadovas
4. Sąranka
4.1 Išpakavimas ir įdėjimas
- Atsargiai išimkite svarstykles iš pakuotės.
- Place the balance on a stable, level, and vibration-free surface, away from drafts, direct heat, and strong electromagnetic fields.
- Ensure adequate space around the balance for operation and ventilation.
4.2 Assembling the Weighing Pan and Draft Shield
- Place the weighing pan support onto the balance.
- Carefully place the weighing pan onto the support.
- For models equipped with a draft shield, assemble the glass panels according to the diagrams provided in the separate assembly guide (if applicable). The sliding doors are designed for easy removal and re-attachment for cleaning.
4.3 Pusiausvyros išlyginimas
The balance features a front bubble level for quick verification:
- Adjust the two leveling feet located at the rear of the balance until the air bubble is centered within the red circle of the level indicator.
- Check the level periodically, especially after moving the balance.
4.4 Maitinimo jungtis
- Connect the power adapter to the balance's power input jack.
- Įkiškite maitinimo adapterį į tinkamą elektros lizdą.
5. Naudojimo instrukcijos
5.1 Įjungimas / išjungimas
- Norėdami įjungti: paspauskite [ON/OFF] button. The balance will perform a self-test.
- Norėdami išjungti: paspauskite ir palaikykite [ON/OFF] mygtuką, kol ekranas išsijungs.
5.2 Ekranas baigtasview
The balance features a digital LCD display without backlight. Key indicators include:
- Svorio vertė
- Unit of measure (e.g., g, mg)
- Stabilumo indikatorius
- Taros indikatorius
5.3 Internal Calibration
The Pioneer PA213 balance features internal calibration for optimal accuracy:
- Ensure the balance is level and stable, with no weight on the pan.
- Refer to the balance's on-screen menu or specific button sequence (usually involving a CAL button or menu option) to initiate internal calibration.
- The balance will perform the calibration automatically. Do not disturb the balance during this process.
- A confirmation message will appear upon successful completion.
5.4 Basic Weighing Procedure
- Turn on the balance and allow it to warm up for a few minutes (typically 15-30 minutes for precision balances).
- Paspauskite [ZERO] or [TARA] mygtuką, kad rodmenis nustatytumėte į nulį.
- Place the item to be weighed on the center of the weighing pan.
- Wait for the stability indicator to appear, then read the weight value on the display.
- To weigh another item in the same container, place the container on the pan, press [TARA], then add the new item.
5.5 Selecting Environmental Parameters
The balance allows selection of environmental parameters for optimal adaptation to external conditions:
- Access the balance's menu settings (refer to the on-screen prompts or specific menu button).
- Navigate to the 'Environmental Settings' or similar option.
- Choose the setting that best matches your operating environment (e.g., stable, unstable, fast). This adjusts the balance's response time and stability filtering.
6. Priežiūra
6.1 Valymas
- Prieš valydami visada atjunkite svarstykles nuo maitinimo šaltinio.
- Clean the exterior of the balance with a soft, damp cloth and a mild detergent. Do not use abrasive cleaners or solvents.
- The weighing pan and draft shield components can be removed for thorough cleaning.
- Ensure no liquids enter the balance housing.
6.2 Saugykla
- When not in use for extended periods, store the balance in a clean, dry, and stable environment.
- Protect the balance from dust using a cover.
7. Problemų sprendimas
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| Balansas neįsijungia | No power supply; faulty power adapter | Check power connection; try a different outlet; replace adapter if necessary. |
| Nestabilūs rodmenys | Drafts; vibrations; unstable surface; unlevel balance; electromagnetic interference | Close draft shield doors; move balance to a stable location; re-level the balance; adjust environmental settings. |
| Netikslūs rodmenys | Balance not calibrated; temperature changes | Perform internal calibration; allow balance to stabilize at ambient temperature. |
| Display shows 'Error' message | Overload; internal fault | Remove excess weight; turn balance off and on; if error persists, contact support. |
8. Specifikacijos
| Funkcija | Specifikacija |
|---|---|
| Modelis | PA213 |
| Prekės kodas | 001519 |
| Talpa | 210 g |
| Ekranas | Digital LCD (no backlight) |
| Kalibravimas | Vidinis kalibravimas |
| Išlyginimas | Front Bubble Level |
| Skydo juodraštis | Included (with easily removable sliding doors) |
| Aplinkos nustatymai | Selectable for optimal adaptation |
| Matmenys (paketas) | 10 x 10 x 10 cm |
| Svoris (prekė) | 10 kilogramo |
| Galios reikalavimai | Battery(s) / Pile(s) required: Yes (Batteries not included) |
9. Informacija žiniasklaidai
No product images or official product videos were provided for inclusion in this manual.
10. Garantija ir palaikymas
OHAUS products are manufactured under stringent quality controls. For warranty information, technical support, or service, please contact your local OHAUS representative or visit the official OHAUS website. Please have your model number (PA213) and product code (001519) available when contacting support.