Produktas baigtasview
The Dometic 317302400 24V DC T Series Discharge Pump is designed for efficient waste discharge in marine and RV applications. This pump operates on a 24-volt DC power supply and is engineered for reliable performance.

1 vaizdas: Dometic 317302400 24V DC T Series Discharge Pump. This image displays the white pump unit with its black motor attached, showing the inlet and outlet ports.
Svarbi saugos informacija
Please read and understand all instructions before installation, operation, maintenance, or service of this product. Failure to do so may result in property damage or personal injury. Contact Dometic Corporation for further information.
- ĮSPĖJIMAS: The motor operates automatically. Keep fingers and hair away from moving parts. Always disconnect power prior to motor testing or servicing.
- ĮSPĖJIMAS: If a toilet system is connected to through-hull fittings, disconnect these fittings when the boat is hauled, winterized, or disassembled.
- ATSARGIAI: Discharging untreated sewage into waterways is prohibited by local and federal regulations. Always check and comply with local regulations.
Sąranka ir diegimas
Proper installation is crucial for the optimal performance and longevity of your Dometic discharge pump. It is recommended that installation be performed by a qualified technician.
- Montavimas: Securely mount the pump in a location that allows for easy access for maintenance and inspection. Ensure the mounting surface is stable and can support the pump's weight.
- Santechnikos jungtys: Connect the inlet and outlet hoses to the appropriate plumbing lines. Ensure all connections are tight and leak-free. Use marine-grade hose clamps for all hose connections.
- Elektros instaliacija: Connect the pump to a 24V DC power source. Ensure proper polarity and use appropriately sized marine-grade wiring and circuit protection (fuse or circuit breaker) as specified in the detailed wiring diagram (not provided in this general manual, refer to product packaging or Dometic's official documentation).
- Sistemos patikrinimas: After installation, perform a thorough system check to ensure all connections are secure and the pump operates correctly without leaks.
Naudojimo instrukcijos
The Dometic 317302400 discharge pump is designed for straightforward operation.
- Maitinimas: Ensure the pump is connected to a stable 24V DC power supply. Activate the power switch for the pump.
- Discharge Cycle: The pump will activate to discharge waste from the holding tank. Depending on the system configuration, this may be initiated manually or automatically.
- Stebėjimas: Observe the pump's operation to ensure proper flow and discharge. Listen for unusual noises that might indicate an issue.
- Išjungti: Deactivate the power switch when the discharge cycle is complete or when the pump is not in use.
Priežiūra
Regular maintenance ensures the longevity and efficient operation of your discharge pump.
- Periodinis patikrinimas: Regularly inspect all hoses, connections, and wiring for signs of wear, corrosion, or leaks. Tighten any loose connections.
- Valymas: Periodically flush the system with fresh water to prevent buildup of solids and odors.
- Žieminimas: Before freezing temperatures, ensure the pump and associated plumbing are completely drained and winterized according to Dometic's specific guidelines for your overall system. This typically involves flushing with non-toxic antifreeze.
- Motor Servicing: Disconnect power before any motor test or servicing. Refer to a qualified technician for internal motor maintenance.
Trikčių šalinimas
If you encounter issues with your Dometic discharge pump, refer to the following common troubleshooting steps:
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| Siurblys neveikia | No power; Blown fuse/tripped breaker; Loose wiring connection; Motor fault | Check power supply; Inspect and replace fuse or reset breaker; Verify all electrical connections; Contact Dometic support if motor fault is suspected. |
| Mažas arba jo visai nėra išleidimo srauto | Clogged inlet/outlet; Air leak in suction line; Kinked hose; Low voltage | Inspect and clear any blockages; Check all hose connections for leaks; Straighten hoses; Verify 24V DC power supply. |
| Siurblys dirba nuolat | Air leak in suction line; Faulty pressure switch (if applicable); Leak in discharge line | Check all hose connections for leaks; Inspect pressure switch; Check discharge plumbing for leaks. |
| Neįprastas triukšmas veikimo metu | Debris in pump; Worn bearings; Loose mounting | Disconnect power and inspect pump for debris; Contact Dometic support for internal component issues; Ensure pump is securely mounted. |
If troubleshooting steps do not resolve the issue, contact Dometic customer support or a qualified service technician.
Specifikacijos
| Funkcija | Detalė |
|---|---|
| Prekės ženklas | Dometic |
| Modelio pavadinimas | 317302400 (T Series Discharge Pump) |
| ttage | 24 voltų DC |
| Maksimalus srautas | 300 galonų per minutę |
| Maksimalus kėlimo aukštis | 190.5 milimetrų |
| Gaminio matmenys (IxPxH) | 7 colio ilgio x 13.5 colių pločio x 7.75 colio aukščio |
| Medžiaga | Plastikiniai |
| Spalva | Baltas |
| Maitinimo šaltinis | Maitinamas baterijomis |
| UPC | 087735101868 |
Garantija ir palaikymas
This Dometic product comes with a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Dometic websvetainę.
For technical assistance, parts, or service inquiries, please contact Dometic customer support. Ensure you have your product model number (317302400) and purchase information available when contacting support.
You can find more information and contact details on the official Dometic websvetainė: www.dometic.com