1. Įvadas
This user manual provides essential information for the correct installation, use, and maintenance of the GVS Elipse SPR492 ABEK1P3 Dust/Vapor Combination Replacement Filters. These filters are designed to be used exclusively with GVS Elipse SPR491/496 half masks. Adherence to these instructions is crucial for ensuring effective respiratory protection and prolonging the lifespan of your filters.
Svarbi saugos informacija: Always refer to the complete GVS Elipse half mask manual for comprehensive safety guidelines, limitations, and proper respirator usage. Do not use these filters in environments with unknown contaminants, oxygen-deficient atmospheres, or immediately dangerous to life or health (IDLH) conditions.
2. Produktas baigtasview
The GVS Elipse SPR492 ABEK1P3 filters are a pair of low-profile, lightweight combination filters offering protection against organic gases and vapors (A), inorganic gases and vapors (B), acid gases (E), ammonia and organic ammonia derivatives (K), and solid and liquid particulates (P3). Their compact design ensures comfort and compatibility with other personal protective equipment.
2.1 Pagrindinės savybės
- Žemas proffile design for enhanced visibility and comfort.
- Lightweight construction reduces user fatigue.
- Easy and quick replacement mechanism.
- ABEK1P3 classification for broad spectrum protection.
2.2 Pakuotės turinys
- One (1) pair of GVS Elipse SPR492 ABEK1P3 Combination Replacement Filters.

Figure 1: GVS Elipse SPR492 ABEK1P3 Combination Replacement Filters. These filters are designed to attach directly to compatible GVS Elipse half masks.
3. Sąranka ir diegimas
Proper installation of the filters is critical for ensuring a secure seal and effective protection. Always handle filters with clean hands.
- Patikrinkite filtrus: Before each use, visually inspect both filters for any signs of damage, cracks, or deformities. Ensure the filter media is intact and not visibly soiled. Do not use damaged filters.
- Prepare Half Mask: Ensure your GVS Elipse SPR491/496 half mask is clean and free from debris. Locate the filter attachment points on both sides of the mask.
- Pridėti filtrus: Align the connection point on the filter with the corresponding attachment point on the half mask. Gently push and twist the filter clockwise until it clicks securely into place. Do not overtighten.
- Repeat for Second Filter: Attach the second filter to the other side of the half mask following the same procedure.
- Atlikite sandarumo patikrinimą: After installing both filters, perform a positive and/or negative pressure seal check as described in your GVS Elipse half mask manual. A proper seal is essential for protection. If a proper seal cannot be achieved, do not enter the contaminated area.
4. Naudojimo instrukcijos
Once the filters are correctly installed and a seal check has been performed, the respirator system is ready for use.
- Respiratoriaus dėvėjimas: Don the GVS Elipse half mask with the installed SPR492 filters according to the instructions provided with your half mask. Ensure the straps are adjusted for a comfortable yet secure fit, maintaining the face seal.
- Vartojamas: Breathe normally. The filters will remove specified contaminants from the air.
- Leaving Contaminated Area: If you detect any odor or taste of contaminants, experience increased breathing resistance, or feel dizzy or nauseous, immediately leave the contaminated area and move to fresh air.
- Nenaudokite: These filters are not suitable for protection against gases or vapors with poor warning properties (e.g., odorless, tasteless), or in situations where the concentration of contaminants is unknown or exceeds the filter's capacity.
5. Priežiūra
Proper maintenance ensures the longevity and effectiveness of your filters.
5.1 Filtro keitimas
- Particulate Filters (P3): Replace when breathing resistance becomes noticeably high.
- Gas/Vapor Filters (ABEK1): Replace immediately if you detect any odor or taste of the contaminant, or if irritation occurs. The service life of gas/vapor filters depends on the concentration of contaminants, humidity, temperature, and breathing rate.
- Bendroji taisyklė: Always replace both filters simultaneously. Do not attempt to clean or reuse expired or saturated filters.
5.2 Saugykla
- Store unused filters in their original, sealed packaging in a cool, dry place, away from direct sunlight and contaminants.
- After use, if filters are not saturated, they can be stored attached to the half mask in a clean, airtight container to prolong their life, especially for gas/vapor protection.
5.3 Valymas
- The exterior of the filters can be wiped clean with a damp cloth. Do not immerse filters in water or cleaning solutions, as this can damage the filter media.
6. Problemų sprendimas
Šiame skyriuje aptariamos dažniausiai pasitaikančios problemos, su kuriomis galite susidurti.
- Problema: You detect an odor or taste of contaminants while wearing the respirator.
Sprendimas: Immediately leave the contaminated area. Check the fit of your half mask and ensure the filters are securely attached. If the issue persists, replace both filters. - Problema: Breathing becomes difficult or noticeably restricted.
Sprendimas: Immediately leave the contaminated area. This indicates that the particulate filter media may be clogged. Replace both filters. - Problema: The filters do not seem to attach securely to the half mask.
Sprendimas: Ensure you are using compatible GVS Elipse SPR491/496 half masks. Check for any debris or damage on both the filter and mask connection points. Align correctly and twist firmly until a click is heard.
7. Specifikacijos
| Atributas | Detalė |
|---|---|
| Modelio numeris | SPR492 |
| Filtro tipas | ABEK1P3 Combination Filter (Organic, Inorganic, Acid Gases, Ammonia, Particulates) |
| Suderinamumas | GVS Elipse SPR491/496 Half Masks |
| Medžiaga | Termoplastinis |
| Pakuotės matmenys | 21.5 x 18.7 x 7.5 cm |
| Pakuotės svoris | 137 g |
| Gamintojas | GVS |
| GTIN (Global Trade Item Number) | 05060233801015 |
8. Garantija ir palaikymas
For specific warranty information regarding your GVS Elipse SPR492 ABEK1P3 filters, please refer to the documentation provided with your purchase or visit the official GVS websvetainėje. Išsaugokite pirkimo įrodymą, jei prireiktų pateikti garantinį ieškinį.
For technical support, product inquiries, or further assistance, please contact your authorized GVS dealer or the GVS customer service department. Contact details can typically be found on the GVS official websvetainę.