Arista Networks DCS-7050S-52-R

Arista Networks DCS-7050S-52-R 7050 Series Switch User Manual

Modelis: DCS-7050S-52-R

1. Įvadas

This manual provides essential information for the installation, operation, and maintenance of the Arista Networks DCS-7050S-52-R 7050 Series Switch. This high-performance switch features 52 SFP+ ports, rear-to-front airflow, and dual 460W AC power supplies, designed for demanding network environments.

Please read this manual thoroughly before attempting to install or operate the device. Retain this manual for future reference.

Saugos informacija

Always observe standard safety precautions when working with electrical equipment. Ensure proper grounding and ventilation. Only qualified personnel should perform installation and maintenance procedures. Disconnect power before servicing.

2. Sąranka ir diegimas

2.1 Komutatoriaus išpakavimas

Carefully remove the switch and all accessories from the packaging. Verify that all components listed in the packing list are present and undamaged. Report any missing or damaged items to your supplier immediately.

2.2 Fizinis įrengimas

The DCS-7050S-52-R switch is designed for rack mounting. Ensure the rack is stable and properly grounded. This model features rear-to-front airflow, meaning cool air enters from the rear of the chassis and exits through the front. Ensure adequate clearance for airflow at both the front and rear of the switch.

Arista Networks DCS-7050S-52-R Switch Front View

1 paveikslas: Priekyje view of the Arista Networks DCS-7050S-52-R switch, showing the SFP+ ports and status indicators. This image illustrates the port layout and general appearance of the device.

2.3 Maitinimo jungtis

The switch is equipped with dual 460W AC power supplies for redundancy. Connect the provided 2XC13-C14 power cords to the AC inlets on the rear of the switch and then to separate, grounded AC power sources. It is recommended to connect to different power circuits for maximum redundancy.

  • Ensure power sources match the switch's input voltage reikalavimus.
  • Connect both power supplies for redundant operation.

2.4 Tinklo ryšiai

The DCS-7050S-52-R features 52 SFP+ prievadai. Insert compatible SFP+ transceivers into the desired ports. Connect appropriate fiber optic or direct attach copper (DAC) cables to the transceivers. Ensure proper cable management to avoid strain on the ports.

2.5 Pradinis įjungimas

After all physical connections are made, power on the switch. Observe the system status LEDs for initial boot-up sequence. Refer to the LED indicators section for status interpretation.

3. Naudojimo instrukcijos

3.1 Maitinimo įjungimas/išjungimas

To power on, ensure power cords are connected. The switch will automatically power on. To power off, disconnect both power cords from their sources. For graceful shutdown, it is recommended to use the operating system commands before disconnecting power.

3.2 Prieiga prie valdymo sąsajos

The switch can be managed via a console port (RJ-45), out-of-band management (OOB) Ethernet port, or in-band management through one of the SFP+ data ports. Connect a console cable to the console port and use a terminal emulator (e.g., PuTTY, Tera Term) with settings: 9600 baud, 8 data bits, no parity, 1 stop bit, no flow control.

3.3 Arista EOS Overview

The Arista DCS-7050S-52-R runs Arista EOS (Extensible Operating System). EOS provides a command-line interface (CLI) for configuration and monitoring. For detailed configuration instructions, refer to the official Arista EOS documentation available on the Arista Networks websvetainę.

3.4 SFP+ Port Operation

The 52 SFP+ ports support 10 Gigabit Ethernet connectivity. Ensure that compatible SFP+ transceivers are used for the desired link type (e.g., SR, LR, DAC). Port status LEDs indicate link activity and speed.

4. Priežiūra

4.1 Valymas

Periodically clean the exterior of the switch with a soft, dry, lint-free cloth. Ensure ventilation openings are free from dust and obstructions. Do not use liquid or aerosol cleaners directly on the switch.

4.2 Firmware atnaujinimai

Regularly check the Arista Networks support website for the latest EOS firmware updates. Follow the provided instructions for safe and effective firmware upgrades to ensure optimal performance and security.

4.3 Komponento keitimas

The DCS-7050S-52-R is designed with hot-swappable components such as fan trays and power supplies. Refer to the Arista Networks hardware guide for specific instructions on replacing these components while the switch is operational.

5. Problemų sprendimas

This section provides basic troubleshooting steps for common issues. For more complex problems, consult the Arista Networks support resources.

5.1 LED indikatoriai

Observe the status LEDs on the front panel for diagnostic information:

  • Sistemos šviesos diodas: Rodo bendrą sistemos būklę (pvz., žalia – normali, geltona – įspėjimas, raudona – kritinė).
  • Maitinimo šaltinio šviesos diodai: Indicate the status of each power supply.
  • Fan LEDs: Indicate the status of the fan trays.
  • Prievado šviesos diodai: Indicate link status and activity for each SFP+ port.

Refer to the Arista Networks documentation for a detailed explanation of all LED states.

5.2 Bendros problemos

  • Nėra galios: Verify power cord connections, power source, and power supply LEDs.
  • Nėra nuorodos prievade: Check transceiver compatibility, cable integrity, and connection to the peer device. Verify port configuration.
  • Sistemos gedimas: Check system LED. If red, consult logs via console or management interface.

5.3 Reset Procedures

A system reboot can often resolve minor issues. Use the appropriate EOS command for a graceful reboot. In cases where the system is unresponsive, a hard power cycle (disconnecting and reconnecting power) may be necessary, but this should be a last resort.

6. Specifikacijos

FunkcijaAprašymas
Modelio numerisDCS-7050S-52-R
GamintojasArista
Sąsajos tipasSFP+
Prievadų skaičius52
Oro srauto kryptisIš galo į priekį
Maitinimo šaltiniaiDual 460W AC
Gaminio matmenys1 x 1 x 1 colio
Prekės svoris2 svaro
Viršutinės temperatūros įvertinimas40 laipsniai Celsijaus
Bylos medžiagaMetalas

7. Informacija apie garantiją

This Arista Networks product is covered by a standard manufacturer's warranty. For detailed information regarding warranty terms, conditions, and duration, please refer to the warranty statement provided with your purchase or visit the official Arista Networks websvetainėje. Išsaugokite pirkimo įrodymą garantiniams reikalavimams.

8. Techninė pagalba

For technical assistance, product documentation, and software downloads, please visit the Arista Networks support portal. You can find comprehensive resources, FAQs, and contact information for their technical support team.

  • Arista tinklai Websvetainė: www.arista.com
  • Palaikymo portalas: Refer to the Arista website for specific support contact details and online resources.

Susiję dokumentai - DCS-7050S-52-R

Preview „Arista Networks 7000“ serijos 1 RU-Gen 2 duomenų centro komutatorių greitojo paleidimo vadovas
Šiame vadove pateikiama esminė informacija apie „Arista Networks 7000“ serijos 1 RU-Gen 2 duomenų centro komutatorių, įskaitant modelius DCS-7048T-A, DCS-7050Q-16, DCS-7050QX-32, DCS-7050S-52, DCS-7050S-64, DCS-7050T-36, DCS-7050T-52, DCS-7050T-64, DCS-7124FX, DCS-7124SX, DCS-7150S-24, DCS-7150S-52 ir DCS-7150S-64, diegimą ir pradinę sąranką.
Preview „Arista 7050X4“ serijos duomenų centro komutatorių greito paleidimo vadovas | Diegimas ir sąranka
Pradėkite naudoti „Arista Networks 7050X4“ serijos duomenų centro komutatorius. Šiame greito paleidimo vadove aprašomas tokių modelių kaip DCS-7050DX4-32S, DCS-7050PX4-32S ir kitų įrengimas, montavimas į stelažą, kabelių tiesimas, sauga ir pradinė konfigūracija. Tai būtina tinklo technikams ir techninės priežiūros personalui.
Preview „Arista“ platformai skirtų funkcijų rinkinio vadovas: ZTP, aparatinės įrangos autentifikavimas, saugus įkrovimas
Vadovas, kuriame išsamiai aprašomos „Arista Networks“ platformoms skirtos funkcijos, skirtos bekontaktiniam aprūpinimui (ZTP) su „CloudVision“ kaip paslauga, aparatinės įrangos autentifikavimui ir saugaus įkrovimo funkcijoms. Įtraukti palaikomų „Arista“ komutatorių SKU ir produktų šeimų sąrašai.
Preview „Arista Networks“ 7280R3A serijos duomenų centro komutatorių greitojo paleidimo vadovas
Šiame „Arista Networks“ greitojo paleidimo vadove pateikiama esminė informacija apie 7280R3A serijos duomenų centro komutatorių diegimą ir pradinį nustatymą. Jame aprašomas šių didelio našumo tinklo įrenginių išpakavimas, montavimas į stelažą, kabelių tiesimas ir pagrindiniai konfigūravimo veiksmai.
Preview DANZ stebėjimo tinklo aparatinės įrangos vadovas | „Arista Networks“
Išsamios „Arista Networks“ DANZ stebėjimo tinklo aparatinės įrangos specifikacijos, komponentų aprašymai ir LED indikatoriai. Apima valdiklio, aptarnavimo, analizės ir įrašymo mazgus bei palaikomus „Arista“ komutatorius.
Preview „Arista CloudEOS“ ir „vEOS“ maršrutizatorių konfigūravimo vadovas
A comprehensive guide detailing the configuration and deployment of Arista CloudEOS and vEOS Router software across various platforms including AWS, Azure, GCP, KVM, and ESXi, covering licensing, high availability, IPsec, DPDK, and appliance-specific setups.