Shelti 210-0195-0

Shelti Gold Standard Games Air Hockey & Dome Hockey Score Sensors Instruction Manual

Modelis: 210-0195-0

1. Įvadas

This manual provides instructions for the installation, operation, and maintenance of the Shelti and Gold Standard Games Air Hockey and Dome Hockey Score Sensors (Part Number 210-0195-0). These sensors are designed as direct OEM replacements to ensure accurate scorekeeping on compatible game tables.

2. Suderinamumas

These score sensors are specifically designed for use with the following Shelti and Gold Standard Games models:

Svarbu: These sensors are not compatible with air hockey tables from other manufacturers.

3. Pakuotės turinys

4. Sąranka ir diegimas

Before beginning installation, ensure the game table is powered off and unplugged from the electrical outlet to prevent injury or damage.

Shelti Gold Standard Games Air Hockey Dome Hockey Score Sensor assembly with black cable and colored wires

1 paveikslas: Shelti Gold Standard Games Air Hockey Dome Hockey Score Sensor assembly. This image displays the sensor unit, which consists of a black cable terminating in a modular connector (likely RJ11 or similar) on one end, and two sensor components connected by thin red, blue, yellow, and green wires on the other end. The main cable is coiled, and the sensor components are black plastic with small metal elements.

  1. Access the Goal Area: Depending on your specific table model, you may need to remove the goal assembly or access panel to reach the existing score sensors. Refer to your game table's primary instruction manual for specific disassembly procedures.
  2. Disconnect Old Sensors: Carefully disconnect the wiring from the old score sensors. Note the orientation and connection points of the wires before removal.
  3. Remove Old Sensors: Unmount the old sensor components from their positions within the goal.
  4. Install New Sensors: Mount the new Shelti/Gold Standard Games score sensor components into the designated slots or brackets within the goal area. Ensure they are securely fastened and properly aligned to detect pucks passing through the goal.
  5. Prijunkite laidus: Connect the wires from the new sensor assembly to the corresponding terminals or connectors on your game table's scoring system. The modular connector (RJ11 type) should plug into the appropriate port on the scoring board or wiring harness. Ensure all connections are firm.
  6. Surinkti iš naujo: Replace any removed panels or goal assemblies.
  7. Bandymo funkcionalumas: Plug in and power on the game table. Test the sensors by passing a puck through each goal to verify that the score registers correctly on the scoreboard.

5. Operacija

Once installed, the score sensors operate automatically. When a puck passes through the goal and interrupts the sensor's beam, the scoring system registers a point for the corresponding player. The sensors are designed for quick and accurate detection.

6. Priežiūra

7. Problemų sprendimas

ProblemaGalima priežastisSprendimas
Score not registeringSensor obstructed or misaligned. Loose wiring connection. Faulty sensor.Check for debris blocking the sensor path. Ensure sensors are securely mounted and aligned. Verify all wiring connections are firm. If issues persist, the sensor may need replacement.
Intermittent scoringLoose connection. Minor obstruction.Inspect wiring for intermittent contact. Clean sensor area thoroughly.
Sensor does not detect fast-moving pucks (Bubble Hockey specific)(Note from product reviews) Sensor response time may not be suitable for very fast puck travel in certain non-compatible setups.These sensors are designed for Shelti and Gold Standard Air Hockey tables. They may not be suitable for other game types, such as some bubble hockey games, where puck travel through the sensor area is extremely rapid. Ensure compatibility with your specific game model.

8. Specifikacijos

9. Garantija ir palaikymas

Specific warranty information for this replacement part may vary. Please refer to your original game table's warranty documentation or contact Shelti customer support for details regarding replacement parts.

For technical assistance or further inquiries, please visit the official Shelti websvetainėje arba susisiekite su klientų aptarnavimo skyriumi.

Susiję dokumentai - 210-0195-0

Preview Shelti Blue Line Thunderdome Home Dome Hockey Table - Model TD-Y-AB
Discover the Shelti Blue Line Thunderdome, a premium home dome hockey table. Featuring an automated puck injector, electronic scoring, ultra-smooth rods, and exciting stadium sound effects for an immersive arcade hockey experience.
Preview Shelti Eye² Coin-Operated Electronic Dart Machine - Features and Specifications
Explore the Shelti Eye² coin-operated electronic dart machine, a durable and feature-rich electronic dartboard designed for commercial use. Learn about its transportability, scoring accuracy, game options, and specifications.
Preview „Dynamo“ ledo ritulio techninės priežiūros vadovas ir instrukcijos
Šiame išsamiame techninės priežiūros vadove ir instrukcijose pateikiama išsami informacija apie „Dynamo“ ledo ritulio stalą, apimanti surinkimą, naudojimą, priežiūrą, trikčių šalinimą ir dalių identifikavimą. Jis skirtas savininkams ir technikams, siekiant užtikrinti optimalų „Dynamo“ ledo ritulio stalo veikimą ir ilgaamžiškumą.
Preview Specter Ops Rules Version 2.0 - Rulebook
Official rulebook for the Specter Ops board game, version 2.0. Learn how to play as an A.R.K. agent or Raxxon hunter, game setup, objectives, movement, combat, and special abilities.
Preview „Potent Hockey Ultimer Dangler 2.0“: naudotojo vadovas ir treniruočių sistema
Išsamus vadovas apie „Potent Hockey Ultimer Dangler 2.0“ – išmaniąją ledo ritulio treniruočių sistemą. Sužinokite apie sąranką, funkcijas, režimus, trikčių šalinimą ir specifikacijas, skirtas pagerinti lazdos valdymą ir ritulio judėjimą.
Preview Boombox Editor User Manual - Cyberspline Games
Comprehensive user manual for the Boombox Editor by Cyberspline Games, detailing how to create and edit rhythm game levels. Covers interface navigation, BPM management, note placement, and controls for Build 0.0.295.