1. Įvadas
This manual provides essential information for the proper installation, operation, and maintenance of your Sauermann KT 220-N Multi-Function Data Logger. Please read this manual thoroughly before using the device to ensure safe and efficient operation. Keep this manual for future reference.
2. Produktas baigtasview
The Sauermann KT 220-N is a versatile multi-function data logger designed for various measurement applications, particularly temperature monitoring. It features a universal probe input, allowing connection of different types of probes (not included) to suit specific measurement needs. This model operates without an integrated display, relying on software for configuration and data retrieval.

2.1 pav.: priekis view of the Sauermann KT 220-N Data Logger. Note the 'OK' and 'Cycle' buttons at the bottom.
Pagrindinės funkcijos:
- Multi-function data logging capabilities.
- Universal probe input for various sensor types.
- Kompaktiškas ir tvirtas dizainas.
- Internal temperature measurement.
- Battery-powered operation.
3. Sąranka
- Išpakavimas: Carefully remove the data logger from its packaging. Verify that all components are present and undamaged.
- Akumuliatoriaus montavimas: The KT 220-N typically comes with batteries pre-installed. If not, locate the battery compartment (usually on the rear or side) and insert the specified batteries, observing correct polarity.
- Zondo jungtis: Connect your desired measurement probe (e.g., temperature, humidity) to the universal input port on the data logger. Ensure a secure connection.
- Programinės įrangos diegimas: Install the Sauermann data logging software (e.g., KILOG) on your computer. This software is essential for configuring the logger, starting/stopping measurements, and downloading data. Refer to the software's specific manual for installation instructions.
- Pradinė konfigūracija: Connect the data logger to your computer via the appropriate interface (e.g., USB). Use the software to set up logging parameters such as measurement interval, start mode, and alarm thresholds.
4. Naudojimo instrukcijos
The KT 220-N is primarily controlled and configured via its dedicated software. The physical buttons on the device provide basic control over logging status.
- Starting a Measurement Campaign:
- Ensure the logger is configured via the software.
- Depending on the configured start mode (e.g., immediate, delayed, button press), the logger will begin recording data.
- If configured for button press start, press the 'OK' button (refer to Figure 2.1) to initiate logging.
- Stopping a Measurement Campaign:
- Logging can be stopped via the software or, if configured, by pressing and holding the 'OK' button.
- The logger will automatically stop when its memory is full or if a programmed stop time is reached.
- Checking Status (if applicable): The KT 220-N does not have a display. Status indicators (LEDs) may provide basic information on logging activity or battery status. Consult the software for detailed status.
- Duomenų atsisiuntimas: Connect the logger to your computer and use the software to download recorded data. Data can then be viewed, analyzed, and exported.
5. Priežiūra
- Valymas: Clean the exterior of the data logger with a soft, damp šluoste. Nenaudokite abrazyvinių valiklių ar tirpiklių. Įsitikinkite, kad į įrenginį nepateko skysčio.
- Baterijos keitimas: When the battery indicator (if present, or via software) shows low battery, replace the batteries with new ones of the specified type. Ensure the device is off before replacing batteries.
- Saugykla: Store the data logger in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.
- Zondų priežiūra: Refer to the specific probe's manual for cleaning and maintenance instructions.
6. Problemų sprendimas
| Problema | Galima priežastis | Sprendimas |
|---|---|---|
| Įrenginys nereaguoja | Žemas arba išsikrovusios baterijos; neteisingas baterijų įdėjimas. | Pakeiskite baterijas; patikrinkite poliškumą. |
| Nepavyksta prisijungti prie kompiuterio | Incorrect USB cable; driver not installed; software not running. | Use correct cable; install drivers; open software. |
| No data being logged | Logging not started; incorrect configuration; full memory. | Start logging via software/button; reconfigure settings; download data and clear memory. |
| Netikslūs rodmenys | Faulty probe; probe not calibrated; environmental interference. | Check probe connection; calibrate probe; ensure stable environment. |
7. Specifikacijos
- Modelis: KT 220-N
- Tipas: Multi-Function Data Logger
- Įvestis: Universal Probe Input
- Ekranas: Nėra
- Maitinimo šaltinis: Baterijos (tipas nurodytas baterijų skyriuje)
- Gamintojas: Zauermannas
- ASIN: B06XC7G96T
- Pirmą kartą pasiekiama data: 1 m. kovo 2017 d
8. Garantija ir palaikymas
Sauermann products are designed for reliability and performance. For information regarding warranty coverage, technical support, or service, please refer to the official Sauermann website or contact your authorized distributor. Keep your purchase receipt as proof of purchase for warranty claims.
Dėl papildomos pagalbos apsilankykite „Sauermann“ grupė websvetainę.