1. Įvadas
The Klein Tools ET120 is a professional-grade combustible gas leak detector designed for HVAC professionals and general household use. It provides audible and visual alarms to indicate the presence of methane, propane, and other combustible gases. This manual provides essential information for the safe and effective operation of your ET120 gas leak detector.

1 pav.: priekis view of the Klein Tools ET120 Gas Leak Detector.
2. Saugos informacija
ĮSPĖJIMAS: This Gas Detector is NOT intended for use as personal protective equipment (PPE). Always read, understand, and follow all instructions to ensure safe operation. Always turn on the gas detector in an area known to be free of combustible gases.
- Nenaudokite prietaiso, jei jis atrodo pažeistas.
- Ensure proper ventilation when investigating gas leaks.
- Laikykite prietaisą atokiau nuo ekstremalių temperatūrų ir drėgmės.
- Kai pasirodys išsikrovusių baterijų indikatorius, nedelsdami pakeiskite baterijas.
3. Produkto ypatybės
- Platus aptikimo diapazonas: Detects gas concentrations from approximately 50 to 10,000 ppm (based on Methane).
- Reguliuojamas jautrumas: Offers High (50 to 1000 ppm) and Low (1000 to 10,000 ppm) sensitivity levels.
- Enhanced Alerts: Features five red LEDs (visual) and an 85dB audible alarm that intensifies with increasing dujų koncentracija.
- Automatinis kalibravimas: Performs automatic zero-point calibration at power-up for accuracy.
- Lankstus žąsies kaklelis: An 18-inch flexible gooseneck expands the sensor's reach and clips onto the meter for storage.
- Patvarus dizainas: Over-molded body provides a comfortable grip and is built for demanding environments.
- Akumuliatoriaus taupymas: Auto power-off after 10 minutes of non-usage conserves battery life.

Figure 2: Key features of the ET120 Gas Leak Detector.
4. Sąranka
4.1 Akumuliatoriaus įdėjimas
The Klein Tools ET120 requires 4 AAA batteries (included). To install or replace batteries:
- Suraskite baterijų skyriaus dangtelį įrenginio gale.
- Open the cover and insert 4 AAA batteries, ensuring correct polarity (+/-).
- Saugiai uždarykite akumuliatoriaus skyriaus dangtelį.

3 pav.: Baterijų skyrius su įdėtomis baterijomis.
4.2 Pradinis kalibravimas
The ET120 features automatic zero-point calibration. When the device is powered on, it will automatically calibrate itself to the ambient air. Ensure the device is powered on in an area known to be free of combustible gases for accurate calibration. Flashing lights will indicate the self-calibration process.
5. Naudojimo instrukcijos
5.1 Maitinimo įjungimas/išjungimas
- To power on, press and hold the power button until the device activates.
- The device will perform an automatic self-calibration.
- To power off, press and hold the power button. The device also features an auto power-off function after 10 minutes of inactivity.
5.2 Jautrumo reguliavimas
The ET120 offers two sensitivity modes:
- Didelis jautrumas: Approximately 50 to 1000 ppm. Use for detecting smaller leaks or when precise location is needed.
- Mažas jautrumas: Approximately 1000 to 10,000 ppm. Use for detecting larger leaks or initial scanning of an area.
Press the 'LOW' or 'HIGH' buttons on the device to switch between sensitivity modes.
5.3 Dujų aptikimo procesas
To detect gas leaks:
- Įsitikinkite, kad įrenginys įjungtas ir sukalibruotas.
- Extend the 18-inch flexible gooseneck to reach the area to be inspected. The gooseneck can be clipped onto the meter for convenient storage when not in use.
- Slowly move the sensor tip of the gooseneck around potential leak sources.
- Observe the five red LED indicators and listen for the audible alarm. The intensity of both the visual and audible alerts will increase as the gas concentration rises, indicating proximity to a leak.
- Use the 'HOLD' button to freeze the current reading on the display if needed.

Figure 4: Using the ET120 to detect gas leaks.
5.4 Nutildymo funkcija
The audible alarm can be muted by pressing the speaker icon button. Press it again to unmute.
Oficialūs produktų vaizdo įrašai
Watch these official videos for a visual guide on using the Klein Tools ET120 Gas Leak Detector:
Video 1: Klein Tools ET120 Gas Leak Detector overview and demonstration. This video shows the device being unboxed and used to check for gas leaks around a propane tank, demonstrating its sensitivity and flexible gooseneck.
2 vaizdo įrašas: Produktas baigtasview Video for the Klein Tools ET120. This video highlights the main features and benefits of the gas leak detector, including its design and functionality.
6. Priežiūra
- Valymas: Wipe the device with a dry, lint-free cloth. Do not use abrasive cleaners or solvents.
- Saugykla: Laikykite prietaisą nešiojimo dėkle vėsioje, sausoje vietoje, apsaugotoje nuo tiesioginių saulės spindulių ir ekstremalių temperatūrų.
- Akumuliatoriaus priežiūra: Jei prietaisas ilgesnį laiką nebus naudojamas, išimkite baterijas, kad išvengtumėte elektrolito pratekėjimo.
7. Problemų sprendimas
- Įrenginys neįsijungia: Patikrinkite baterijų įdėjimą ir įsitikinkite, kad jos nėra išsikrovusios. Jei reikia, pakeiskite.
- Netikslūs rodmenys: Ensure the device was calibrated in a clean, gas-free environment. Recalibrate if needed.
- No audible alarm: Check if the mute function is activated. Press the speaker icon button to unmute.
8. Specifikacijos
| Specifikacija | Vertė |
|---|---|
| Prekės ženklas | KLEIN ĮRANKIAI |
| Modelio numeris | ET120 |
| Stilius | Degios dujos |
| Maitinimo šaltinis | Maitinamas baterijomis |
| Spalva | Juoda |
| Gaminio matmenys | 1.79 "D x 2.71" P x 28.3" A |
| Prekės svoris | 13 uncijos |
| Signalizacija | Audible, Visual Notification |
| Darbinė drėgmė | 85 procentų |
| Medžiaga | Sumaišykite |
| Reikalingos baterijos | 4 AAA baterijos (pridedamos) |
| Ypatingos savybės | Audible Alert, Auto-Power Off, Visual Notification |
9. Garantija ir palaikymas
For warranty information, please refer to the attached warranty document that came with your product. For technical support or further assistance, please contact Klein Tools customer service.